Part Location Diagram of WB27X11213 GE Microwave Fan Thermostat
See part 27 in the diagram
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

customerservice@partselect.com

Microwave Fan Thermostat WB27X11213

★★★★★
★★★★★
3 Reviews

Rated by 2 customers 

Easy 

30 - 60 mins 

Ratings submitted by customers like you who bought this part.

$ 31.34
  In Stock

Get this part fast! Average delivery time for in-stock parts via standard shipping: 1.8 days.

PartSelect Number PS8754628
Manufacturer Part Number WB27X11213
Manufactured by GE
Troubleshooting
This part fixes the following symptoms:
Won’t turn on
This part works with the following products:
Microwave, Range, Microwave Oven Combo.
This part works with the following products:
General Electric, Hotpoint.
Part# WB27X11213 replaces these:
AP5791057, SE-7350-004, WB24X28950, WB27X10846
Back to Top
Customer Reviews
Average Rating:
★★★★★
★★★★★
3 Reviews
2.7
Filter By Rating:
  • 5 Stars
    1
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    1
  • 1 Star
    1
Sort by:
  • 1
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
Customer Repair Stories
 Average Repair Rating: 3.0 / 5.0, 2 reviews. What's this?
Sort by:
  • 1
Sorry, we couldn't find any existing installation instruction that matched.
Thermal Fuse out
There are videos on YouTube on how to do this but there are a couple of things I’m going to recommend. Color code your plugs when you take the main control panel off, be patient when removing the screws on the thermal fuse use a 45 degree screwdriver but replace the screws with a small hex head self tapper screw for next time. The difference between these two lookalike fuses is that one is for the fan and the other one is the thermal there’s a price difference and volts so read the back of the bad fuse. These guys are great man and thank you for helping me out.
Other Parts Used:
Microwave Fan Thermostat THERMOSTAT 120/0 Charcoal Filter
  • Jorge from PANORAMA CITY, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blown Fuse
Turned power off, removed screws from outer cover, opened door, slide cover off, removed screws, lifted panel open, removed electrical connections, then removed keypad panel. Removed screws for fan cover then removed cover. Saw blown fuse replaced fuse also used ohm meter to measure resistance of the thermostat it was shorted. removed screw holding it in place removed 2 connectors took out thermostat inserted new thermostat screwed in place put connectors back on. Put fan cover on put screws in, put key panel on reconnect all connections to key panel put screws in put cover on, screw in, turn power on.
  • Mike from West Deptford, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
  • 1
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

19 questions answered by our experts.
Sort by:
  • 1
  • 2
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Dale
January 9, 2019
Power cord has power. Nothing works on microwave. Glass fuse is fine, i tested it. What else am i overlooking?
For model number PVM9005DJ2BB
PartSelect logo
Hello Dale, thank you for your question. We would recommend testing the thermostat, part number WB27X11213. If the fuse is fine, and the unit is getting power, the thermostat may be blown which would prevent the unit from powering up. When testing this part this thermostat should be open at room temp and closes at a set temp. If the thermostat is fine the next step would be to test the main board part number WB27X25603. I hope this helps!

7 people found this helpful.

Was this helpful?
Thank you for voting!
JOE
December 11, 2018
Opening the door while microwave is in use trips the circuit breaker
For model number jvm3160rf2ss
PartSelect logo
Hello Joe, thank you for your question. Inside the microwave are three micro switches; primary and secondary interlock micro switches and an Interlock Monitor switch. The switches are supposed to shut down the microwave if it is running and the door is opened. But, I've found the upper primary switch can stick internal at times and when the door is opened the stuck switch will, because of the way it is wired as a safety switch, cause either the fuse or possibly the main circuit breaker for the oven to pop. We would recommend testing the switches to determine which one is faulty and replacing the corresponding switch. Here is a link that will show you how to test these switches. https://www.partselect.com/Microwave+test-door-switch+repair.htm I hope this helps!

6 people found this helpful.

Was this helpful?
Thank you for voting!
Carol
August 20, 2019
A cotton potato bag set the bag on fire and just burnt the bag. The microwave does not work. The part has a g and ksd 201 and 70. Is this a thermostat? Thanks for helping me.
For model number JVM3160DF1bb
PartSelect logo
Hello Carol, thank you for writing. Unfortunately the numbers you provided off the part do not help locate it, but if your microwave will no longer turn on, you may want to consider replacing either the Thermostat part number PS8754628 or the Fuse part number PS3486694. I hope this helps and good luck with your repair!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Andrew
April 3, 2019
How difficult is it to replace the thermal fuse? Does the capacitor need to be discharged or can this be done without doing that? Thank you.
For model number JVM3160DF2WW
PartSelect logo
Hello Andrew, Thank you for the question. When ever working with a microwave, it will need to be discharged. Most customers have said it was a easy repair and took under 30 mins to do. Hope this helps!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Steven
October 15, 2019
Won't heat anything inside unit
For model number PVM9005EJ1ES
PartSelect logo
Hello Steven, Thank you for the question. If the appliance is running normally but not producing heat, you can check the Thermostats PartSelect Number: PS8754627, PS8767141 and PS8754628. You can test the thermostats with a multi meter to check for continuity. Hope this helps!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
C R
April 8, 2023
My microwave fan continues to run when door is closed. I have leave the door open for it to stop. I've unplugged microwave for 30 minutes for a hard reset, but that doesn't fix it. Could it be a faulty thermostat? thanks.
For model number PVM9005SJ3SS
PartSelect logo
Hi, thank you for reaching out. According to our research, we suggest you clean the air filter, and grease filter, which may be clogged due to dirt, and dust build-up inside the filter preventing air circulation. Also, check the fan thermostat, part number PS8754628, which may be damaged. We hope this sorts out your problem!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Dale
April 10, 2019
No nothing works and the fuse is good.
For model number JVM3160DF2BB
PartSelect logo
Hello Dale, thank you for inquiring. If the microwave will not turn on then you will want to replace either the Thermostat part PS8754628, or the Fuse part PS3486694. We hope this helps.

Was this helpful?
Thank you for voting!
Ben
July 18, 2019
Display lights up, but blows breakers when you hit start.
For model number JVM3160DF3WW
PartSelect logo
Hi Ben, Thank you for your question. If the microwave is tripping the breaker when it is turned on, then the microwave is either malfunctioning or their are too many appliances plugged into the same circuit. If the microwave is malfunctioning =, Plug the microwave into an area where the breaker is set for a higher amp rating (like a garage), then turn on the microwave and see what happens. If the circuit breaker in that area trips, it’s a sign that something is wrong with the microwave. You should either have the microwave fixed, or replace it. If the breaker does not trip, it means the microwave is fine, but it needs its own dedicated circuit. If you have too many appliances plugged into the same circuit, look at the label on the tripped breaker. If it says microwave, it is probably on a dedicated circuit. If not, it is likely that the microwave is sharing a circuit with other appliances and the circuit is becoming overloaded. I hope this helps. Thank you and have a great day!

Was this helpful?
Thank you for voting!
Jonathan
December 15, 2017
I think the microwave overheated and I need to replace the thermal fuse, but I cannot find a part by that name. Should I replace the thermostat 120/0 part number PS8754627 or thermostat - 70/40 part number PS8754628 or how can I tell which one needs to be replaced?
PartSelect logo
Hello Jonathan, Thanks for your question. The part number PS8754627 is the thermal fuse thermostat used for your model. I hope this helps.

Was this helpful?
Thank you for voting!
Related Parts:
Carol
August 21, 2019
Microwave has no power so we tested the thermostat and has no continuity. Is it necessary to find and check the fuse too. Thanks again.
For model number JVM3160DF1bb
PartSelect logo
Hello Carol, Thank you for the question. Yes, I suggest checking the fuse, PartSelect Number: PS3486694. This sounds like a blown fuse. Hope this helps!

Was this helpful?
Thank you for voting!
Related Parts:
  • 1
  • 2
Model Cross Reference
This part works with the following models:
PartSelect Number: PS8754628
Manufacturer Part Number: WB27X11213
Brand
Model Number
Description
General Electric
AVM4160DF1BS
Microwave
General Electric
AVM4160DF1WS
Microwave
General Electric
AVM4160DF2BS
Microwave - MICROWAVE
General Electric
AVM4160DF2WS
Microwave - MICROWAVE
General Electric
AVM4160DF3BS
Microwave - MICROWAVE
General Electric
AVM4160DF3WS
Microwave - MICROWAVE
General Electric
CVM721M2N1S5
Microwave
General Electric
HMV1472B1HS
Microwave
General Electric
HMV1472B2HS
Microwave
General Electric
HMV1472B3HS
Microwave - Microwave
General Electric
HMV1472B4HS
Microwave - Microwave
General Electric
HMV1472BHS
Microwave
General Electric
HVM7167RN1SS
Microwave Oven Combo
General Electric
HVM7167RN1TS
Microwave Oven Combo
General Electric
JNM3160DF1BB
Microwave
General Electric
JNM3160RF1SS
Microwave
General Electric
JNM3161DF1BB
Microwave
General Electric
JNM3161DF1CC
Microwave
General Electric
JNM3161DF1WW
Microwave
General Electric
JNM3161DF2BB
Microwave - MICROWAVE
General Electric
JNM3161DF2CC
Microwave - MICROWAVE
General Electric
JNM3161DF2WW
Microwave - MICROWAVE
General Electric
JNM3161DF3BB
Microwave - Ge Microwave Model Jnm3161df3bb Parts
General Electric
JNM3161DF3CC
Microwave - Ge Microwave Model Jnm3161df3cc Parts
General Electric
JNM3161DF3WW
Microwave - Ge Microwave Model Jnm3161df3ww Parts
General Electric
JNM3161DF4BB
General Electric
JNM3161DF4CC
General Electric
JNM3161DF4WW
General Electric
JNM3161MF1SA
Microwave
General Electric
JNM3161MF2SA
Microwave - MICROWAVE/HOOD COMBO
Customer Service Representative