SWITCH MICRO MONITOR WB24X10205
$
60.20
In Stock
Get this part fast! Average delivery time for in-stock parts via standard shipping: 1.8 days.
PartSelect Number PS8754455
Manufacturer Part Number WB24X10205
Manufactured by
GE

Check if this fits your product and find model diagrams
Need help finding your model number?
Troubleshooting
This part fixes the following symptoms:
Won’t turn on
This part works with the following products:
Microwave, Range, Microwave Oven Combo.
This part works with the following products:
General Electric, Hotpoint.
Part# WB24X10205 replaces these:
AP5790849, WB24X10147
Customer Reviews
Filter By Rating:
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
Thomas R S - May 14, 2020
Verified Purchase
Microwave works like new
The right parts at a fair price. An easy repair for a non professional.
Gerald J - March 9, 2020
Verified Purchase
Microwave door switch
My part was the part I ordered and it went in as expected. It worked for about a week and then it quit working again. I haven't had the time to take it apart again to see if the part is what failed this time. I will take it apart again this week and let you know.
Dale C - January 25, 2020
Verified Purchase
It was the correct part and went in easily.
Part came a day early, and in perfect condition.
Saul B - August 16, 2018
Verified Purchase
Part partly helped
micro switch was one of 4 parts needed to repair a microwave oven. Repair was complete when all replacement parts were installed
- < Prev
- 1
- Next >
Customer Repair Stories
Average Repair Rating: 2.3 / 5.0, 1 reviews.
What's this?
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
door switch monitor broke ,tripped breaker
when on line to see how to replace the micro switch, very helpful.be careful removing door latching housing & vent cover.unplug control panel & set aside so it's out of the way.
Other Parts Used:
-
Earl from STOW, OH
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
- < Prev
- 1
- Next >
Questions and Answers
Ask our experts a question about this part and we'll get back to you as soon as possible!
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Doug
November 5, 2017
Can this door switch cause the microwave to trip the circuit breaker? Breaker is dedicated to the microwave.The breaker trips in the 1st second of operation! The existing switch does not have any open-close movement? Just a hard spongy feeling when pushed in?Any help will be appreciated! Thank you.
For model number JVM3160RF3SS
Hi Doug, Thank you for the question. If the microwave is tripping the breaker it is usually because it is pulling to much amperage.I suggest testing the High Voltage Capacitor.Hope this helps!
4 people found this helpful.
Was this helpful?
Thank you for voting!
Stephan
November 6, 2018
Microwave keep blowing fuse when i close the door. Is the middle switch a normally close or open. If one of the thermal fuse in front of the control panel is bad can that also cause the problem.
For model number JVM3160RF2SS
Hi Stephan, thank you for your question. Your door switches can be both open and closed. When the switch is actuated by the button that you see on the side, it will be in the NO (Normally Open) position, and when it is not activated it will be in the NC (Normally Closed position). It could cause the problem. I would suggest testing your switch with a multi meter to make sure it is working correctly. If it is, you may have to go on to look at your fuse, diode, and capacitor. You must be careful when looking at those parts. If you do not properly discharge the capacitor before doing repairs you could be dangerously shocked. I hope that helps. Good luck with your repair.
4 people found this helpful.
Was this helpful?
Thank you for voting!
Don
January 3, 2019
My microwave will not turn off when i close the door. Its not heating just lights and fan running.It started giving us fits a few weeks ago and you could only close the door a certain way to get it to stop. Now it just wont stop. The control buttons will not work either. Have any ideas?
For model number JVM1630WK01
Hello Don, Thank you for the question. I suggest checking the Latch Broad, Part Number: PS1019899 for damage or wear. There is also a Lever Release, Part Number: PS1016159 to check for damage. If they check out good, you can test the switches with a multi meter. The switches are Part Number: PS8754454, Part Number: PS8754455 and Part Number: PS1019163. Hope this helps, good luck with this repair!
2 people found this helpful.
Was this helpful?
Thank you for voting!
Related Parts:
Chuck
January 18, 2019
My 1 yr old GE otc micro is tripping a dedicated 20amp breaker when we open the micro door during cooking. If we wait for the micro to finish its cycle, no problem . However, last night the micro will now trip the breaker "immediately whenever started". Micro switch or breaker failure?
For model number JVM3160DF4WW
Hi Chuck,
Thank you for your question. If the microwave is tripping the breaker either the microwave is malfunctioning and pulling too much electrical current or you have too many electrical appliances, including the microwave, plugged into the same circuit. Try plugging the microwave into a different outlet to see if the same thing happens. If it trips the breaker than the issue is caused by a part inside the microwave. It could be the micro switches causing this and you will need to check the parts to see which one is causing the issue. I hope this helps. Thank you and have a great day!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Alex
September 12, 2019
How much does it cost?
For model number PS8754455
Good Day Alex. Thank you for your question in regards to PartSelect Number PS8754455. If you search the part number on our website www.PartSelect.com, and click "Add to Cart" followed by "Checkout" this will bring you to the shipping option screen. From here you can pick your choice of shipping and again click on "Checkout". On the next screen if you enter in our Zip Code you will see what the total current price including shipping and any applicable taxes would be for this part. Hope this helps. Best Regards.
Was this helpful?
Thank you for voting!
Larry
October 22, 2021
My microwave died - no control panel lights, no heating. I took the panel off and found the thermostat (thermal fuse) on the right was blown, so I will replace it. But then I tested the door micro switch monitors. The top and bottom are normally closed and tested correctly. But the middle (2nd from bottom) tested open even though it is marked "normally closed". So, I figured that was broken. But some online videos say that middle switch should be "normally open". Perhaps my microwave was installed incorrectly with a "normally closed" at the factory -- I find that hard to believe, and it has worked for 4 years. My question is, should the middle switch be "normally closed" or "normally open"?
For model number JVM3160DF3WW
Hello Larry, Thank you for the question. The Switch depends on the model. Some are normally Closed and others Normally Open. The one for your appliance should be Normally Closed. We suggest replacing the Switch. We hope this helps!
Was this helpful?
Thank you for voting!
- < Prev
- 1
- Next >
✖
Ask a Question
Ask our experts a question on this part and we'll respond as soon as we can.
Something went wrong. Please try again later.
Your Question Has Been Submitted!
Our experts will send you an email as soon as your question has been answered.
You May Also Need?
Model Cross Reference
This part works with the following models:
PartSelect Number: PS8754455
Manufacturer Part Number: WB24X10205
Manufacturer Part Number: WB24X10205
Brand
Model Number
Description