Part Location Diagram of 5304491584 Frigidaire Compressor Relay and Overload
See part 30 in the diagram
( Grid squares measure 1x1 inch )
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

customerservice@partselect.com

Compressor Relay and Overload 5304491584

 Fits your CFU14M2AW0!
★★★★★
★★★★★
2 Reviews

Rated by 5 customers 

Easy 

15 - 30 mins 

Ratings submitted by customers like you who bought this part.

$ 80.27
  In Stock
Get FREE EconoShip on orders over $100! T&C apply

Get this part fast! Average delivery time for in-stock parts via standard shipping: 1.8 days.

 Fits your CFU14M2AW0!
PartSelect Number PS8689570
Manufacturer Part Number 5304491584
Manufactured by Frigidaire
Product Description

Compressor Relay and Overload Specifications

This part is both the start relay and the overload. The start relay boosts the compressor, and then shuts off as soon as the motor gets up to speed and the overload provides extra protection against excessive temperatures.
How Buying OEM Parts Can Save You Time and Money

How Buying OEM Parts Can Save You Time and Money

Troubleshooting
This part fixes the following symptoms:
Won’t start | Too warm
This part works with the following products:
Freezer.
This part works with the following products:
Frigidaire, Kenmore, Uni, Gibson.
Part# 5304491584 replaces these:
AP5690408, 216649313, 216649318
Back to Top
Customer Reviews
Average Rating:
★★★★★
★★★★★
2 Reviews
5.0
Filter By Rating:
  • 5 Stars
    2
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Star
    0
Sort by:
  • 1
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
Customer Repair Stories
 Average Repair Rating: 4.2 / 5.0, 5 reviews. What's this?
Sort by:
  • 1
Sorry, we couldn't find any existing installation instruction that matched.
Compressor stopped running, freezer stopped freezing
Upon Inspection of electrical connections I found the controller connector slightly melted, so I ordered a replacement and the other parts, given the freeezers age.
Replacement efforts were close to plug and play.
Compressor powered back up And freezer is now functioning again.
Other Parts Used:
DEFROST TIMER Compressor Relay and Overload Defrost Thermostat Run Capacitor
  • Joseph from BANDON, OR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor Stopped Running. Fan and lights still working.
1. Ensure that the power is completely removed from the freezer. 2. Using needle-nose pliers and a screw driver, remove the wire retainer holding the controller assembly to the compressor and remove the controller assembly by pulling away from the compressor. 3. Cut the two wires from the existing controller assembly and strip the ends about a quarter of an inch. 4. Slide the heat shrink tubing over the wires of the connector provided with the controller kit. 5. Use the Blue Barrel connectors provided with the controller kit to connect the controller wires provided in the kit to the existing wires of the freezer. **Ensure that they are well crimped. 6. Using a heat gun, shrink the tubing to fit over the connector and wires. **Be careful not to overheat. 7. Plug the connector into the new controller provided in the kit. 8. Plug the controller assembly back into the socket on the compressor. 9. Reattach the wire retainer securely to hold the controller assembly to the compressor. 10. Plug in the freezer and adjust the thermostat so that the compressor energizes. If the controller was the issue your freezer should begin to cool.
  • Jerry from FORT SMITH, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer compressor quit running causing freezer to defrost and ruin all contents.
Very simple repair. Removed the bail that holds the compressor controller and run capacitor from the compressor, removed the controller & capacitor, inserted a very small screwdriver into the controller to compress the barbs that hold the electrical wires to the controller. Plugged in the wires to the new controller in the same position as the original, plugged in the capacitor and then plugged the entire unit back onto the compressor, replaced the wire bail, plugged in the freezer and repair was complete.
Other Parts Used:
Run Capacitor Compressor Relay and Overload
  • Kenneth from Safford, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Controller showed signs of the plastic housing had melted.
I paid attention to how the old part came off. You need a small (very small) flat bladed screwdriver to release the two wires that plug into the controller. I checked that it was a bit difficult but it would had been easier if I could have found a screwdriver sooner.
  • Jim from Cherryvale, KS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Faulty Controller and Possibly Capacitor
After building a test box and determining the Controller was bad simply ordered parts and installed. Installation was a little difficult due to locking spades on electrical connections.

Unplug all power from freezer. Remove Bail wire from controller capacitor unit and remove from compressor by pulling STRAIGHT from compressor body to avoid bending contacts.

Use a very small instrumentation screwdriver to release locking spade on yellow and white wires. To unlock slide screwdriver in slot along wire entry to controller body while gently pulling on wire. Note position of wires and replace on new unit in same position/order. Plug new run capacitor into new controller being careful to orient capacitor to proper position (hole matches guide on controller unit). Plug newly installed controller and capacitor into condensor and replace bail wire.

Make sure timer is not in defrost mode - manually advance timer if necessary to ensure timer is in run mode. Turn temperature control to coldest setting. Plug in and hopefully enjoy the humming noise of your newly repaired and operational compressor and freezer.
Other Parts Used:
Run Capacitor Compressor Relay and Overload
  • eric from inglewood, TN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
33 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
  • 1
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

2 questions answered by our experts.
Sort by:
  • 1
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Clyde
July 8, 2021
I bought this part. The instructions say the wire colors should match, but the wires on the new harness are both white. The existing harness the wires are blue and white. Since the connector on the new is a different layout than the existing, I can't even match the locations up. How do I determine which side of the connector the blue or white wires of the existing harness should mate to.
For model number FFU14C3AW0
PartSelect logo
Hello Clyde, Thank you for the question. The terminal that is closest to the center of the relay will be the Neutral and the outer terminal will be the L1. We hope this helps!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Matthew
July 25, 2023
I bought this and the original one had a place to plug-in the capacitor. This one does not. How do I now connect the capacitor?
For model number FFC13K1AW0
PartSelect logo
Hi Matthew, thank you for contacting us. We have found that the capacitor is connected to the relay through the two terminals at the top adjacent to the pin. After connecting the wires, line the capacitor to the two terminals so that the terminals go into the start device and then line the pin up so that the capacitor is held in place. Then press the capacitor down and snap it in. We hope this sorts out your problem!

Was this helpful?
Thank you for voting!
  • 1
You May Also Need ?
Model Cross Reference
This part works with the following models:
PartSelect Number: PS8689570
Manufacturer Part Number: 5304491584
Brand
Model Number
Description
Kenmore
25311311100
Freezer
Kenmore
25311312100
Freezer
Kenmore
25311312101
Freezer
Kenmore
25311521100
Freezer
Kenmore
25311521102
Freezer
Kenmore
25311531100
Freezer
Kenmore
25311531101
Freezer
Kenmore
25311541100
Freezer
Kenmore
25311541102
Freezer
Kenmore
25312021101
Freezer
Kenmore
25312541100
Freezer
Kenmore
25313051100
Freezer
Kenmore
25321021105
Freezer
Kenmore
25321041105
Freezer
Kenmore
25321041107
Freezer
Kenmore
25321041108
Freezer
Kenmore
25321401100
Freezer
Kenmore
25321401101
Freezer
Kenmore
25321402100
Freezer
Kenmore
25321402101
Freezer
Kenmore
25321402102
Freezer
Kenmore
25321402103
Freezer
Kenmore
25321411100
Freezer
Kenmore
25321411101
Freezer
Kenmore
25321411102
Freezer
Kenmore
25321411103
Freezer
Kenmore
25321421100
Freezer
Kenmore
25321421101
Freezer
Kenmore
25321421102
Freezer
Kenmore
25321421103
Freezer
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

Contact Customer Service