JOHN
November 6, 2018
The wire broke at the terminal box. All i need is a new spade clip or end. Do i have to buy the whole wiring kit just to get one wire end?
For model number LE6150XSW0
Hello Jon, Thank you for the question. The spades are only sold as part of the wiring kit sorry. Thank you for your inquiry, good luck with this repair!
5 people found this helpful.
Was this helpful?
Thank you for voting!
Shatarra
November 26, 2017
Does this kit come with the terminal block?
For model number NED4655EW1
Hi Shatarra,
Thank you for your question. It does not. The terminal block is a separate part. I have linked it below for you. Good luck with your repair.
My wiring kit has 4 wires. A black, white and red go to to terminal block. There is a separate white wire on mine that is fastened to a Green screw. I noticed this kit has a white and Green wire so i’m confused how to hook up. Can you explain this?
For model number WED4800XQ0
Hello and thank you for writing.
The black, white, and red go on the terminal block the green /white one is the ground which will go to the green screw. We hope this helps. Please contact us anytime if you require further assistance.
2 people found this helpful.
Was this helpful?
Thank you for voting!
Fernando
March 9, 2023
This model have a plug of three long and one in form of an L, do you know if by any chance there is any adapter to make it a regular plug?
For model number 110.69422800
Hello Fernando, thank you for your question. To convert your plug to the desired plug, you need to follow these instructions. Use a UL-listed power supply cord kit marked for use with clothes dryers. Choose a 4-wire power supply cord with ring or spade terminals and UL-listed strain relief. The 4-wire power supply cord, at least 4 ft long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire may be either green or bare. The neutral conductor must be identified by a white cover. We hope this helps!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Judith
November 4, 2019
My son-in-law calls it a wire harness and says it looks fried. Are these the ones that would go in there? I also want to know what could have caused this and did it fry the protect motor? We tested the fuses, the switches and the thermostat and the continuity is still there. The unit will not start, any other suggestions?
For model number WED4900XW0
Hi Judith,
Thank you for your question. This would not be the correct wire harness. The part number listed under your model number for the wire harness is PS1490143. I hope this helps. Thank you and have a great day!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Marcy
December 20, 2017
What heating element do i need for this model Kenmore dryer?
For model number 11068132410
Hi Marcy,
Thank you for your question. The part number for the heating element listed under you model number is PS11770230. I hope this helps. Thank you and have a great day!
Was this helpful?
Thank you for voting!
Maelyn
January 28, 2018
Is there an option to just buy the screws and nuts? I am missing one of the nuts so i cannot screw in one screw. Would rather not buy the whole terminal and wire kit just for one nut.
For model number MEDX600XW0
Hello Maelyn, thank you for your question. Unfortunately, the manufacturer only sells these parts as a kit. You would have to order the set of parts. I hope this helps!
Was this helpful?
Thank you for voting!
Dianna
December 14, 2019
It’s a thermal switch wires are hooked up wrong with the dryer still start but then shut off later
For model number Wed8500dc4
Hello Dianna and thanks for writing.
Yes, the wrong wiring could cause this. It also could be a faulty thermostat internal PS11746740 test the part after you check the wires and replace it if needed. We hope this helps. Please contact us anytime.
Is this the correct piece for UL wire size that goes with the terminal block. I'm concerned that these are the thin wires and not a 10/4, SRDT (ROUND)
For model number MEDX700XW1
Hi Alverina, thank you for your question! Yes, this is the correct size terminal and wire kit for the terminal block of your model. We hope that helps!
Item is in stock and will ship today if your order is placed before 4:00 PM Eastern Standard Time.
If your order is placed after 4:00 PM EST, the in stock items will ship on the next business day.
On Order
Item is not in stock and usually ships 3-5 business days from the time you place your order.
Special Order
Item is not in stock and usually ships 10-15 business days from the time you place your order.
NLA - No Longer Available
This item is no longer being made by the manufacturer, and cannot be added to your shopping cart.
[{"position":0,"name":"Home","title":"Home","url":"/"},{"position":1,"name":"Dryer","title":"Dryer","url":"/Dryer-Parts.htm"},{"position":2,"name":"Wire Plug or Connector","title":"Wire Plug or Connector","url":"/Dryer-Wire-Plugs-and-Connectors.htm"},{"position":3,"name":"279318","title":"279318","url":""}]
You added 1 item to your cart
✖
$
Qty:
Total item(s) in cart:
Order Subtotal
$
*Taxes and shipping will be applied during checkout