Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Larry
April 10, 2018
I found overload wr08x1005 but can not find # for start relay for the compressor
For model number DSF25KGTABG
Hi Larry, Thank you for the question. The start relay is also known as the Run Capacitor, PartSelect Number: PS11764031. Hope this helps!
4 people found this helpful.
Was this helpful?
Thank you for voting!
Louis
November 7, 2018
Both doors were left open by accident overnight. Defrosted freezer and when turned on the temps were on target but within a short period of time both refrigerator and freezer began heating up.. don't feel warm air coming from bottom of unit. what could be the likely problem. i ordered , defrost thermo, heater & bracket, and temp senso. not sure if i should order the blower motor as well. what would be the most likely part to fail under the above mentioned circumstances.
For model number PSS26SGRESS
Hi Louis, thank you for your question. Actually, the parts that you have ordered would be the parts that I would suggest checking. Generally when you are having cooling issues those are the parts that are the issue. Now you could also take a look at your evaporator fan motor as well. Just to check if it is still functioning and has not burned out. I hope that helps. Good luck with your repair.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Jimmie
August 19, 2019
My refrigerator does not run at all the light for the inside works, but all the lights for the temerature controls do not. Last night all the temperature control lights were working but blinking.
For model number CFCP1NIZASS
Hello Jammie, Thank you for the question. This sounds like an issue with a defective Control Board, PartSelect Number PS1766240. Hope this helps!
Was this helpful?
Thank you for voting!
Patty
December 24, 2019
Fridge won't start after power outage
For model number PSS26SGPASS
Hello Patty,
Thank you for your question. If the fridge wont start after a power outage, it is likely that the control board became fried or defective because of the outage, and would need to be tested and possibly replaced. The part number for your control board is under part PS12069099 for your model. We hope this helps!
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
Fridge and Freezer too warm
Took off the back cover, unplug it of course, use the flat screwdriver to pop off the cap on the compressor and just unplug the two units detached wires put em on the new units and plug the parts back to compressor, plugged in the fridge to see and it didn't come on so I left it for a day in discussed, came home from work and it was running? Have no idea why it would do that but it's running now and the temperature's are good?
With our Fix app model plate image recognition technology, we'll recommend the parts guaranteed to fit your appliance. Simply snap a photo, and we'll take care of the rest.
"I love love love this app. It's so nice to have useful information (receipts, manuals, parts lists, warranty info, pictures, etc.) on all of my household appliances and devices in one place."
You added to your cart
✖
$
Qty:
Total item(s) in cart:
Order Subtotal
$