Recess Door Spring Specifications

This door recess spring or dispenser lever spring in your refrigerator is used to return the ice door to the closed position or the dispenser lever to the home position once released. You will find the spring in the water dispenser assembly, behind the main control panel. If the dispenser lever is malfunctioning or the dispenser ice door is not closing, you may need to replace this door recess spring.

How Buying OEM Parts Can Save You Time and Money

Troubleshooting

This part fixes the following symptoms:

Door latch failure, Door Sweating, Ice maker won’t dispense ice, Door won’t open or close.

This part works with the following products:

Refrigerator, Dishwasher.

This part works with the following brands:

General Electric, Hotpoint.

Part # WR02X10585 replaces these:

879075, AP3670155, WR2X10585.
Part Videos

Replacing your General Electric Refrigerator Recess Door Spring

Customer Repair Stories
Average Repair Rating: 3.5 / 5.0, 44 reviews What's this?
Sort by:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Bill from Cleveland Heights, OH
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
WR62X10055, WR17X11497, WR23X10783, WR02X10585
flap to ice dispenser would not close
The flap to the ice dispenser would not close, which allowed the ice dispenser to frost up, freezing the water dispenser.

This was a simple fix. The solenoid had stopped working, so it would not automatically close the door flap. I read some posts on this site that suggest that you had to remove the trim around the entire dispenser to get at the solenoid. My fridge may be a newer model, but in any event it was much easier than that. Just below the touch pad for choosing water, ice, or crushed ice (above where the ice/water dispenses) there are three very small holes spaced about an inch a part. After unplugging the fridge, I stuck a small philips-head screw driver in each, freeing spring clips. That allowed the touch pad to come off. I then removed four screws to remove a plastic piece covering the chute, giving me access to the flap and solenoid. I just unplugged the solenoid from the circuit board on the back of the touch pad and then removed three screws to remove the old solenoid. I replaced it with the new solenoid and plugged it into the circuit board. The touch pad then snapped back into place.

The hardest part was figuring out how to get at the solenoid. After I found that pushing the clips in those three holes allowed me to remove the touch pad, it could not be any easier.
406 of 466 people found this instruction helpful.
Was this instruction helpful to you?
Joe from Maryville, TN
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
Parts Used:
WR62X10055, WR17X11653, WR23X10783, WR02X10585
Flapper Door Stuck Open Allowing Ice Tube To Frost Shut
I read in a previous post how to do the job from outside fridge which saved me lots of time. No need to remove inner door lining. Here is my procedure:
1.Turned off power. 2.Snapped off outside trim ring. 3.Located three small holes inside lip just above ice tube. The center hole was not used. 4.Pushed rather firmly up through two remaining holes with small Allen wrench to release front control panel. 5.Removed (3) wire connectors from printed circuit board. Firmly pull/pry them straight out as lifting on retaining clip will break it off. I broke one & had to elect. tape it back in place later although I doubt it would have ever come off. 6.Release secondary panel by removing (4) screws. The problem was obvious as the solenoid had broken the crank arm off the flapper rod & trapped it open 7.Replaced solenoid, crank arm with flapper attached, spring & micro switch. Switch was okay but I changed anyway. 8.Cleaned all areas with 1/10 bleach water to sanitize. 9.Re-installed evrything in reverse order & all is okay. Thanks to someone for telling about those two small holes. Made job easy versus a very hard one.
159 of 210 people found this instruction helpful.
Was this instruction helpful to you?
James from Malabar, FL
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Parts Used:
WR62X10055, WR17X11653, WR17X11267, WR17X10706, WR02X10585
Ice Chute Flapper not closing causing water dripping to floor and ice chute freezing up solid
I followed the video instructions for replacing the Flapper Valve and solenoid that Part Select suggested. It was one of the best DIY Reapair Sites I've used. Thank you
132 of 181 people found this instruction helpful.
Was this instruction helpful to you?
carl from vacaville, CA
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
WR62X10055, WR55X10270, WR2X8818, WR23X10783, WR17X10706, WR02X10585, WR49X10233
ice and water would not dispense at door
first I snapped out control face plate on outside of door. removed the screws for each part,and unplugged the wires at the connectors, replaced new parts and plugged in connectors to new circuit board.I decided to replace the board,switch and solenoid all at the same time, not knowing which part was bad.I have to say it was well worth it! it works better than when it was new!!!! It was a lot easier than I thought it was going to be.
91 of 139 people found this instruction helpful.
Was this instruction helpful to you?
ERIC from MADISON, AL
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Parts Used:
WR62X10055, WR17X11653, WR23X10783, WR17X10706, WR02X10585
Ice door would not open far enough, ice would get stuck in chute
First remove about 30 screws w/nutdriver that are hidden under door seal then inside of freezer door will come off. Second remove about 10 screws that hold dispenser assy to the inside of door, then support the unit with tape so you don't damage the wires that connect it. Third, pop touchpad loose, then remove three sets of wires plugged into the circuit board. Fourth, remove four screws that hold the ice chute and light assy. Fifth, now remove the 3 screws that hold solenoid. These three screws that hold the solenoid will be very rusty, you may want to replace these also. I went ahead and replaced all the related parts because they are so hard to get to. Also took the opportunity to clean in here with bleach to remove all the black mold and rust.
NOTE: when reassembling the inside of the freezer door to the outside of the door you must loosely attach the door on both sides in the middle first, then the top and bottom. Add some more screws on each side and tighten them all. Now you must check to be sure that the door is not racked. If the door is not sealed at the top or bottom, loosen the screws and twist the door a little and tighten screws and check door again for proper seal. Spent more time adjusting door to seal right than doing the actual repair.
71 of 131 people found this instruction helpful.
Was this instruction helpful to you?
Turcotte's Housing Service, In from Newmarket, NH
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
66 of 88 people found this instruction helpful.
Was this instruction helpful to you?
Walt from Alabaster, AL
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
WR62X10055, MWFP, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Ice buildup in the door of freezer
Pulled the ice/water control panel off using the three holes under the lip. Pops off pretty easy. Next came 4 screws holding the chute for the ice. Two bottom screws were very rusty, top two look brand new. Watch the wires. Replace the solenoid assembly by unplugging wires leading to the board, then removed the plunger over the top of the hook on the far right. Went ahead and replaced the dispenser door assembly or flapper. Plugged refridge back in and pressed the ice dispenser handle and listened for the solenoid to cycle. Perfect. There is a little delay before you hear the flapper fall into place. Saving rest of parts just in case they are needed next time.Thanks to everyone who wrote in to show how easy it would be. No telling how much a repairman would have charged me.
63 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Victor from Houston, TX
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.

I recomend these parts be replaced once time for each two years.
38 of 59 people found this instruction helpful.
Was this instruction helpful to you?
John from Oxford, IA
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
WR17X11653, WR2X9561, WR23X10783, WR17X10706, WR02X10585
Frost in ice chut, flapper hanging partially open.
Removed control panel, snapped out pretty easy. Removed flapper assembly (4 small screws). My spring was broke but it ended up being the solenoid assembly after I replaced the spring, door crank, micro switch and flapper it was obvious the solenoid was hanging up. I had to go back an order it but it was at my door 2nd day (quickly). I took the time to clean the area with Tylex (some mold), and everything went in easily. I didn't really need the new flapper, crank, and micro switch but they were fairly cheap and then all is new. We use our ice dispenser a great deal so I didn't want to have to go back in and fix a part I "should have" replaced. I used Part Select for my washer motor as well. Doing both repairs myself probably saved 3 or 4 hundred dollars easily.
36 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Bruce from Mebane, NC
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Parts Used:
WR49X10233, WR62X10055, WR17X11653, WR57X10032, WR2X8818, WR23X10783, WR1X1505D, WR17X10706, WR02X10585, WR01X10019
Ice cube production stopped; ice cube chute door is seized.
Problem: I have a black colored GE 24.9 cubic inch side-by-side refrigerator, model #GSH25KGMCBB that I purchased new in 2002. The ice cube maker stopped supplying ice cubes and the ice dispenser door stopped operating.

Repair: Unplugged refrigerator first and shut off the house water supply valve. Removed the lower rear access cover and replaced the double solenoid water valve. Icemaker and water dispenser tubing are easily removed by pushing in and holding down the white plastic collar where the tubing is inserted into each port on the valve body; no tools required to release the tubing. Hint: When reconnecting the water outlet tubing, ensure the tube diameter matches the port on the valve body. Insert each tube by hand back into the ports of the valve until they firmly seated.

Removed the control panel by inserting a small screwdriver into the three holes located on the bottom of the control panel body. Removed all of the ice dispenser door hardware and the door solenoid. The door solenoid armature was seized by corrosion. Cleaned off all of the accumulated dirt and mold with a 1:10 ratio solution of bleach and water. Replaced all of the door recess and solenoid valve fasteners with my own stainless steel #4-40 thread, 0.25" long socket head screws for longer life. The installation of the remaining hardware is the reverse of how it was removed.

The installation looks very clean now and $150 later, the ice maker still doesn't produce ice!

Root-cause analysis: I disconnected the ice cube maker water supply line from the double solenoid valve at the rear of the refrigerator and was able to blow air with my mouth straight through the outlet of the water tubing located inside of the freezer compartment; to ensure it wasn't blocked. Verified the water supply valve is not being energized! Turns out that the blinking green LED indicator on the ice cube maker is indicating more than the troubleshooting guide does about that because the white colored insulated conductor in the electrical harness for the ice cube maker is not energizing the solenoid on the water supply valve!

Conclusion: the ice cube maker assembly is next on the list of replacement parts!!
34 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Customer Reviews
Average Rating:
10 Reviews
5
out of 5
Filter By Rating:
  • 5 Stars
    10
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Stars
    0
Sort by:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Dispenser Door Recess Crank
$5.05
PartSelect #: PS291908
The door recess crank for your refrigerator is located inside the water dispenser assembly. To access this part, you will need to take apart the dispenser assembly. To do this, you will need a putty knife and a Phillips ...
Model Cross Reference

This part works with the following models:

PartSelect Number: PS285013
Manufacturer Part Number: WR02X10585
Brand
Model Number
Description
General Electric
40201-0
Dishwasher
General Electric
402011
Dishwasher
General Electric
40205-0
Dishwasher
General Electric
402051
Dishwasher
General Electric
40206-0
Dishwasher
General Electric
402061
Dishwasher
General Electric
402070
Dishwasher
General Electric
403110
Dishwasher
General Electric
403111
Dishwasher
General Electric
405010
Dishwasher
General Electric
405011
Dishwasher
General Electric
405012
Dishwasher
General Electric
405050
Dishwasher
General Electric
405051
Dishwasher
General Electric
405052
Dishwasher
General Electric
405060
Dishwasher
General Electric
405061
Dishwasher
General Electric
405062
Dishwasher
General Electric
4070100
Dishwasher
General Electric
4070110
Dishwasher
General Electric
4070500
Dishwasher
General Electric
4070510
General Electric
4070600
Dishwasher
General Electric
4070610
Dishwasher
General Electric
4070800
Dishwasher
General Electric
4070810
General Electric
4071100
Dishwasher
General Electric
4071110
General Electric
4071120
Dishwasher
General Electric
4071500
Dishwasher