would blow the internal 15amp fuse when pressing the start button
Used the trouble shooting guide and wire diagram found inside the microwave (thanks GE). Found the HV capacitor and diode had shorted. Replaced the capacitor and diode........works like new.
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
1 question answered by our experts.
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Harvey
August 16, 2021
Is capactior part#wb27x10073 attached to magnetron part#wb27x10516)
For model number jkp90dp1ww
Hi Harvey,
Thank you for your question. The capacitor is not connected to the magnetron. There are wires that are connected to the capacitor that will have to be removed before replacing it. For safety reasons, since the microwave capacitor can still store electricity even when the microwave is unplugged, it is usually advised that you discharge the capacitor before any attempt at repair. We have included a link on how to do so.