Part Location Diagram of WB27X10037 GE Diode Cable
See part 6006 in the diagram
( Grid squares measure 1x1 inch )
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

customerservice@partselect.com

Diode Cable WB27X10037

★★★★★
★★★★★
3 Reviews

Rated by 4 customers 

Easy 

1- 2 hours 

Ratings submitted by customers like you who bought this part.

$ 30.78
  In Stock
Get FREE EconoShip on orders over $100! T&C apply

Get this part fast! Average delivery time for in-stock parts via standard shipping: 1.8 days.

PartSelect Number PS239148
Manufacturer Part Number WB27X10037
Manufactured by GE
Troubleshooting
This part fixes the following symptoms:
No heat
This part works with the following products:
Microwave, Microwave Oven Combo, Wall Oven, Range.
This part works with the following products:
General Electric, Kenmore, Hotpoint.
Part# WB27X10037 replaces these:
AP2025948, 769835, WB18X10286, WB27X1033, WB27X10330
Back to Top
Customer Reviews
Average Rating:
★★★★★
★★★★★
3 Reviews
3.7
Filter By Rating:
  • 5 Stars
    2
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Star
    1
Sort by:
  • 1
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
Customer Repair Stories
 Average Repair Rating: 3.0 / 5.0, 4 reviews. What's this?
Sort by:
  • 1
Sorry, we couldn't find any existing installation instruction that matched.
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
Other Parts Used:
Diode Cable SWITCH MONITOR INTERLOCK Primary Door Interlock Switch
  • Robert from COLORADO SPGS, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave went totaly blank - No power
Disassembled the front cover, found slow blow fuses, then replaced with microwave fuses 250V-20Amp. Utilized a few fuses to pin point the problem, Microwave functions all worked except the express feature, made an assumption after using a tester that it was the high voltage capacitor and the diode that attaches. Replaced both, plugged in and tested. Worked! reinstalled the unit. Sucessfull for the past month.
Other Parts Used:
USE PRO TJ13QBP21100 Diode Cable
  • Mark from Bushwood, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Wrench set
8 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dishwasher would not pump water out. Othre appliance was advantium oven.
Removed the dishwasher. Simple to remove and replace the pump, flapper, and o-ring. Reinstalled dishwasher. It worked!
The GE Advantium was another story. Replaced the Magnetron, diode, and capacitor. Oven still did not work so I took it to the dump. No more GE!
Other Parts Used:
Drain Pump Inlet Flapper / Baffle Lower Wheel Assembly Drain Pump O-Ring Diode Cable MAGNETRON Assembly USE PRO TJ13QBP21100
  • Christopher from Chruchville, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench set
91 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would not heat food
First and most important - unplug AC power 24 hours before service.

I removed the vent cover above the main door, then I removed the screw which holds the control panel in place, unplugged the main connector on the control panel so I would have enough room to work, removed grounding screw from the DIODE ASSY, pulled connector off the CAPACITOR with pliers, installed new DIODE ASSY.

After installation of DIODE and the control Panel, I plugged in the AC power and allowed the CAPACITOR to charge - this takes about an hour or so, then test. Works perfect!
  • Robert from Dayton, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
17 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
  • 1
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

8 questions answered by our experts.
Sort by:
  • 1
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Kathryn
January 17, 2018
Everything is working but food is not heating/cooking
For model number PVM1790SR1SS
PartSelect logo
Hi Kathryn, Thank you for the question. I suggest testing or replacing the Diode Cable, PartSelect Number PS239148 or the Capacitor, Part Number: PS2339855. If these parts are good you may need a new Magnetron. Hope this helps!

2 people found this helpful.

Was this helpful?
Thank you for voting!
Thomas
November 13, 2018
I replaced the in line fuse, diode cable and the capacitor and the micorwave is still unresponsive and will not turn on. Any other suggestions? Could i have received a bad in line fuse?Thanks,
For model number zsc1001kss01
PartSelect logo
Hello Thomas, thank you for your question. If the unit lights are working, but the microwave wont star I would recommend checking the door switches on the unit, part number WB24X10029 and WB24X817 to see if these switches are faulty. If the unit is working but not heating the magnetron would be the next part to replace to fix this issue. I hope this helps!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Debra
January 22, 2019
The microwave turns in and seems like it is working but the food does not heat up. What could be the cause? It is only 4 years old.
For model number PVM9179SFSS
PartSelect logo
Hello Debra, Thank you for the question. The first part to check is the Diode, PartSelect Number PS239148. It should read around 50K Ohms. You can also test the thermostat, PartSelect Number PS2321365. It should show continuity. If both are good, you may have a defective Magnetron, PartSelect Number PS11729114. Thank you for your inquiry, good luck with this repair!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
Laura
January 14, 2019
The microwave works for about 7 minutes then shuts down; goes completely dark with no Led's, then after about 10-15 minutes it comes back to life with all the proper led's displaying. But if i run it for 7 minutes or so the same thing keeps happening.Thanks so much!
For model number SCB2000CBB
PartSelect logo
Hi Laura, Thank you for your question. If the microwave is shutting off and then coming back on, one of the door switches is likely causing the issue and you will need to test them to see which one is causing the issue. I hope this helps. Thank you and have a great day!

Was this helpful?
Thank you for voting!
Laura
January 14, 2019
The advantium microwave works for about 7 minutes then shuts down; goes completely dark with no led's, then after about 10-15 minutes it comes back to life (with either the door open or shut)with all the proper led's displaying. But if i run it for 7 minutes or so the same scenario keeps repeats itself. The door switches have been checked and are ok. Thanks so much!
For model number scb2000cbb
PartSelect logo
Hello Laura, thank you for your question. We would recommend testing the thermostats in the unit. It sounds like a thermostat issue is cutting the unit off. The thermostat part numbers are PartSelect Number: PS2321366 and PartSelect Number: PS235672. I hope this helps!

Was this helpful?
Thank you for voting!
Laura
January 15, 2019
I am trying to understand your suggestion. Are you saying a faulty thermostat could let the oven run for the 7 or so minutes then shut off, then completely cause it to go dark , no light even when the door opens, power off, and then come back on and appear to be normal?
For model number SCB2000CBB03
PartSelect logo
Hi Laura, Thank you for your question. You will need to check both the thermostats and the door switches. If these parts are malfunctioning, then they can cause oven not to work correctly. I hope this helps. Thank you and have a great day!

Was this helpful?
Thank you for voting!
Lee
August 30, 2019
My microwave works great but the oven part does not get hot
For model number JVM1490SH
PartSelect logo
Hello Lee, thank you for writing. If your microwave is not heating up, you will want to replace either the Micro Switch part number PS3522738, or the High Voltage Capacitor part number PS3517241 for your model to fix it. Good luck with your repair!

Was this helpful?
Thank you for voting!
Ken
September 21, 2021
Convection oven heats, but not to right temperature. Set it at 350 and range thermometer shows 250
For model number JE1590SH02
PartSelect logo
Hello Ken, Thank you for the question. If the issue only happens in Convection mode and the Heater tests good, you may need to replace the Electronic Control Board. We hope this helps!

Was this helpful?
Thank you for voting!
Related Parts:
  • 1
You May Also Need ?
Model Cross Reference
This part works with the following models:
PartSelect Number: PS239148
Manufacturer Part Number: WB27X10037
Brand
Model Number
Description
Kenmore
36363672200
Microwave
Kenmore
36363672201
Microwave
Kenmore
36363673200
Microwave
Kenmore
36363674200
Microwave
Kenmore
36363674201
Microwave
Kenmore
36363679200
Microwave
Kenmore
36363679201
Microwave
Kenmore
36363692301
Microwave
Kenmore
36363692302
Microwave
Kenmore
36363692303
Microwave
Kenmore
36363693301
Microwave
Kenmore
36363693302
Microwave
Kenmore
36363693303
Microwave
Kenmore
36363694301
Microwave
Kenmore
36363694302
Microwave
Kenmore
36363694303
Microwave
Kenmore
36363699301
Microwave
Kenmore
36363699302
Microwave
Kenmore
36363699303
Microwave
Kenmore
36363703600
Microwave
General Electric
CEB1590SS1SS
Microwave
General Electric
CEB1590SS2SS
Microwave
General Electric
CEB1590SS3SS
Microwave - MICROWAVE
General Electric
CPLMB186KCB
Hotpoint
CSA1201RSS01
Microwave
Hotpoint
CSA1201RSS02
Microwave
Hotpoint
CSA1201RSS03
Microwave
General Electric
CSA1201RSS04
Microwave - MICROWAVE
General Electric
CSA1201RSS05
Microwave - MICROWAVE
General Electric
CSB9120SJ1SS
Microwave - MICROWAVE
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

Contact Customer Service