Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
★★★★★
★★★★★
Richard F - February 27, 2018
Verified Purchase
Easy repair
The part was in great ready to work order. I installed and my microwave is back in business! My family is vet hapoy
★★★★★
★★★★★
Harold F - February 3, 2021
Verified Purchase
Easy to install
This part was very easy to install but turned out not to be the problem. Have to order other parts to get this microwave to work.
★★★★★
★★★★★
Gerald W - November 21, 2019
Verified Purchase
SAD
No parts have been delivered. Have been waiting for 3 weeks.???????!! Can’t review if I can’t get parts
November 22, 2019
Good Morning, thank you for your review. We have emailed you in regards to this issue. We look forward to hearing from you!
< Prev
1
Next >
Customer Repair Stories
Average Repair Rating: 3.0 / 5.0, 4 reviews.
What's this?
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry
... Read more up. Removing grnd wires helps
Disassembled the front cover, found slow blow fuses, then replaced with microwave fuses 250V-20Amp. Utilized a few fuses to pin point the problem, Microwave functions all worked except the express feature, made an assumption after using a tester that it was the high voltage capacitor and the diode that attaches. Replaced both, plugged in
... Read moreand tested. Worked! reinstalled the unit. Sucessfull for the past month.
Dishwasher would not pump water out. Othre appliance was advantium oven.
Removed the dishwasher. Simple to remove and replace the pump, flapper, and o-ring. Reinstalled dishwasher. It worked! The GE Advantium was another story. Replaced the Magnetron, diode, and capacitor. Oven still did not work so I took it to the dump. No more GE!
First and most important - unplug AC power 24 hours before service.
I removed the vent cover above the main door, then I removed the screw which holds the control panel in place, unplugged the main connector on the control panel so I would have enough room to work, removed grounding screw from the DIODE ASSY, pulled connector o
... Read moreff the CAPACITOR with pliers, installed new DIODE ASSY.
After installation of DIODE and the control Panel, I plugged in the AC power and allowed the CAPACITOR to charge - this takes about an hour or so, then test. Works perfect!
Read less
Robert from Dayton, NV
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
18 of 24 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
< Prev
1
Next >
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
8 questions answered by our experts.
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Kathryn
January 17, 2018
Everything is working but food is not heating/cooking
For model number PVM1790SR1SS
Hi Kathryn, Thank you for the question. I suggest testing or replacing the Diode Cable, PartSelect Number PS239148 or the Capacitor, Part Number: PS2339855. If these parts are good you may need a new Magnetron. Hope this helps!
2 people found this helpful.
Was this helpful?
Thank you for voting!
Thomas
November 13, 2018
I replaced the in line fuse, diode cable and the capacitor and the micorwave is still unresponsive and will not turn on. Any other suggestions? Could i have received a bad in line fuse?Thanks,
For model number zsc1001kss01
Hello Thomas, thank you for your question. If the unit lights are working, but the microwave wont star I would recommend checking the door switches on the unit, part number WB24X10029 and WB24X817 to see if these switches are faulty. If the unit is working but not heating the magnetron would be the next part to replace to fix this issue. I hope this helps!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Debra
January 22, 2019
The microwave turns in and seems like it is working but the food does not heat up. What could be the cause? It is only 4 years old.
For model number PVM9179SFSS
Hello Debra, Thank you for the question. The first part to check is the Diode, PartSelect Number PS239148. It should read around 50K Ohms. You can also test the thermostat, PartSelect Number PS2321365. It should show continuity. If both are good, you may have a defective Magnetron, PartSelect Number PS11729114. Thank you for your inquiry, good luck with this repair!
The microwave works for about 7 minutes then shuts down; goes completely dark with no
Led's, then after about 10-15 minutes it comes back to life with all the proper led's displaying. But if i run it for 7 minutes or so the same thing keeps happening.Thanks so much!
For model number SCB2000CBB
Hi Laura,
Thank you for your question. If the microwave is shutting off and then coming back on, one of the door switches is likely causing the issue and you will need to test them to see which one is causing the issue. I hope this helps. Thank you and have a great day!
Was this helpful?
Thank you for voting!
Laura
January 14, 2019
The advantium microwave works for about 7 minutes then shuts down; goes completely dark with no led's, then after about 10-15 minutes it comes back to life (with either the door open or shut)with all the proper led's displaying. But if i run it for 7 minutes or so the same scenario keeps repeats itself. The door switches have been checked and are ok. Thanks so much!
For model number scb2000cbb
Hello Laura, thank you for your question. We would recommend testing the thermostats in the unit. It sounds like a thermostat issue is cutting the unit off. The thermostat part numbers are PartSelect Number: PS2321366 and PartSelect Number: PS235672. I hope this helps!
Was this helpful?
Thank you for voting!
Laura
January 15, 2019
I am trying to understand your suggestion. Are you saying a faulty thermostat could let the oven run for the 7 or so minutes then shut off, then completely cause it to go dark , no light even when the door opens, power off, and then come back on and appear to be normal?
For model number SCB2000CBB03
Hi Laura,
Thank you for your question. You will need to check both the thermostats and the door switches. If these parts are malfunctioning, then they can cause oven not to work correctly. I hope this helps. Thank you and have a great day!
Was this helpful?
Thank you for voting!
Lee
August 30, 2019
My microwave works great but the oven part does not get hot
For model number JVM1490SH
Hello Lee, thank you for writing. If your microwave is not heating up, you will want to replace either the Micro Switch part number PS3522738, or the High Voltage Capacitor part number PS3517241 for your model to fix it. Good luck with your repair!
Was this helpful?
Thank you for voting!
Ken
September 21, 2021
Convection oven heats, but not to right temperature. Set it at 350 and range thermometer shows 250
For model number JE1590SH02
Hello Ken, Thank you for the question. If the issue only happens in Convection mode and the Heater tests good, you may need to replace the Electronic Control Board. We hope this helps!