freezer did not run at all
i order the defrost timer and the temperaturecontrol as was advised,it was very simple as reading the previous notes, pulled knob off, rerout temp metal probe, while the cover was off i clean it as much as i could and repainted the bottom with applince paint, looks good as new, very easy, whent to the defrost timer was so simple unscreewbracket, pull wire clip harness replace harness rescreew bracket, replug freezer it's good as new, saved a lot of money, i love this web site
Parts Used:
DEFROST TIMER Temperature Control Thermostat
  • HUGO from GILBERTSVILLE, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
When I was ready to instal fan motor, I noticed that there was no thread where I was supposed to screw in the bolts
When i found out there was no thread in brace where bolts were supposed to screw in, I panicked. I thought I would have to send part back or go to a machine shop to make a thread. I called a friend for help and he told me the bolts would make the thread if I just screwed them in. Sure enough, the bolts made the thread and then I just proceeded to instal motor and put refrigerator back together. It was simple.
Parts Used:
FAN MOTOR EVAP 115V
  • hector from los fresnos, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Parts Used:
FAN MOTOR EVAP 115V Evaporator Fan Blade
  • Richard from Clovis, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Needed a freezer key
We really didn t need to do a repair, we just ordered a freezer key that we didn t have. I must say the shipping was fast we received it the next day. It was worth the shipping charge. We will be ordering again. Great service.
Parts Used:
Freezer Door Key
  • Nancy from Star Lake, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
freezer door got locked and we couldn't find the key
inserted key and turned
Parts Used:
Freezer Door Key
  • Linda from Fresno, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Evaporator Fan Motor Noise
The evaporator fan would make a very high-pitched whine/squealing noise usually after starting up after a defrost cycle, although, it would make the same noises during normal operation. After performing a thorough inspection of the fan blade and motor, I discovered that there was no interference to the rotating fan, and realized the motor must be failing. After removing the food and racks from the main body of the freezer, I had to remove 8 Philips-tipped screws that held the inside back panel cover on. I disconnected the fan motor from the main wiring harness, removed the fan mounting bracket (2 5/16" hex head screws), and then removed the fan motor from the mounting bracket (2 5/16" hex head bolts. I removed the fan blade and conducted a visual inspection, and found not blemishes of broken/damaged pieces. I mounted the new motor and used the existing fan blade, and replaced everything in the reverse order. I turned on the freezer and it has been operating perfectly since. I disassembled the old motor and discovered that the stator coils were worn, and the bearings allowed to much forward/aft motion.
Parts Used:
FAN MOTOR EVAP 115V Freezer Door Key
  • Louis from Leander, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer was warm
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% category though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Parts Used:
DEFROST TIMER
  • Charles from Macomb, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
thermostate stop working frozzen up
just like the video show sa 1,2,3 yeaaa thanks
Parts Used:
Defrost Thermostat
  • Augusto from Gretna, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Parts Used:
FAN MOTOR EVAP 115V
  • Mike from Satellite Beach, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The defrost timer burned out.
This is an upright Frigidaire freezer. The defrost timer is at the bottom left side of the rear of the unit. One screw holds it in place and it only plugs in one way. When your freezer won't stay cold enough to freeze this is the first part to check. It is cheep to replace (20-30 dollars) and will usually fix the problem. It took about 5 minutes to replace the part and my freezer is up and running like new.
Parts Used:
DEFROST TIMER Compressor Relay and Overload
  • Steven E from Lisle, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
would not defrost
Replace thermostat and show and tell made it easy.
Parts Used:
Defrost Thermostat
  • Nick from Silver Spring, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Parts Used:
FAN MOTOR EVAP 115V
  • CRAIG from PRESCOTT VALLEY, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Would not freeze or defrost
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Parts Used:
Defrost Thermostat
  • RONALD from Sevierville, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer was no longer keeping items frozen,
I followed the You-Tube instructions, removed the ice from the compressor and replaced the thermostat with the part I received from Part Select. What I took out was a part that was very much inferior to the replacement part. The repair saved me a lot of money for a new freezer and it was not difficult to do following the video. Now the freezer runs better and quieter than ever. Thank you Parts Select.
Parts Used:
Defrost Thermostat
  • Philippa from New York, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Parts Used:
DEFROST TIMER
  • Joseph from Yulee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the WFU17FC4CW0