Bulb burned ot
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base
Parts Used:
Light Bulb - 40W 130V
  • John from Fort Smith, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was running when I opened the door.
I replaced the switch at the bottom per instruction. I had both switches. I think it was the monitor door switch.It works fine now. Thank you Part Select .
Parts Used:
Monitor Door Switch
  • Teddy from CLERMONT, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Power worked but would not cook
Took the front panel off, played with the switch while it was plugged in to verify the switch was bad. I actually was able to tweak the switch just right to keep the microwave working while the part was being delivered. When it came it was just removing two small screws and replacing. Very easy.
Parts Used:
Secondary Door Switch
  • Jim from Albuquerque, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken glass and bad bulb
Removed one screw, slid frame out and removed broken glass. replaced bulb. The hard part was slidding the frame back in place and starting the screw. We were very surprised at the fast delivery of the parts, thank you. The sad part, a few days later the glass broke again. We are trying to get to the people at GE to solve our problem. We feel like that will not happen, we just do not have the time to stay on hold on the phone waiting for someone to solve our problem. Will reorder glass.
Parts Used:
Glass Light Lens Light Bulb - 40W 130V
  • Chris from Destin, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave appeared to work. Fan worked, timer worked plate rotated. It just didn't heat the food!
I purchased the fuse and 3 door switches from PartSelect. Replaced the fuse first but that did not solve the problem. Then I replaced the 3 door switches and problem solved!! So fuse only cost $5.00 so glad I have a new fuse in there as well. To see how to replace door switches see videos on utube!!
Parts Used:
Secondary Door Switch
  • Mark from Hanover Park, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
MICROWAVE SHUT OFF COMPLETELY
UNPLUG MIRCOWAVE.REMOVE THE HARDWARE, COVERS, AND DECONNECT THE CONTROL PANEL. REMOVE AND REPLACE VENT THERMOSTAT. REINSTALL EVERTHING IN REVERS ORDER. WORK FINE NOW. ADVISE IF YOUR FIRST TIME GET INSTRUCTIONS ON INTERNET SEARCH OR YOU TUBE
Parts Used:
Vent Thermostat
  • GENE from SHREVEPORT, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would turn on when door opened
Unscrewed numerous screws holding the "body/shell" to the microwave. Removed body. I then unplugged top door switch, replaced it with new one, and "tested" the new one. I fixed our $400 convection micro with an $18 switch. NICE!
Parts Used:
Secondary Door Switch
  • Lois from El Segundo, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Left light socket was damaged beyond repair
Handed the part to my son. He unscrewed 5 screws in the base of the microwave, it dropped down. The light mechanism was clearly in view. With the exception of some corrosion on the old piece, it was simple to remove and replace, put back together, screw back up and all worked fine.
Parts Used:
Light Socket - 250V 75W
  • Kathleen from Streamwood, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light bulb burned out and assembly broke when trying to replace bulb
I used the internet and your directions to complete the repair. It was easy!
Parts Used:
Light Bulb - 40W 130V Light Socket - 250V 75W
  • Jeanne from Kirkwood, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bulb fused to jolder
removed electrical wires, unscrewed holder, inserted holder, attached wires, added bulb, and put cover back on.
Parts Used:
Light Socket - 250V 75W
  • James from Big Rock, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave wouldn’t shut off when door was opened
Followed the online videos to enter the cavity to the switch holder. Noticed right away the dreaded capacitor was in back right corner behind where the touch pad had been removed. I isolated the capacitor with an old computer mouse pad for extra safety. Took some manipulations to get the switch mount out from behind the wire bundles. Once out front, easy to use small flat blade screwdriver to release each switch and replace with matching new switch. Only one switch was bad but replaced all three. Back together and working great.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • John from POWHATAN, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Inside Bulb went out.
Remove top air grate via 2-screws. Remove metal top panel behind grate that's above bulb via 1-screw. Bulb is exposed and can be un-screwed. DONE
Parts Used:
Light Bulb - 40W 130V
  • Richard from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Total power loss of microwave
GE slate microwave approximately 2 years old. Completely dead. Power to outlet was good, no gfci was tripped. Started checking fuses, 250v ceramic fuse good, two fuses at the bottom behind the control panel. One on the left labeled 12 on the diagram tested no continuity. One on the right labeled 13 tested good with continuity. So i figured number 12 was bad. Got the part and turns out to be the wrong fuse. Part number was the same but the terminals were the wrong size. Im pretty sure GE has the diagram labeled wrong because i ordered number 13 and it was the right size. Just an FYI if you are ordering those fuses for your microwave that 12 and 13 on the diagram may be reversed. Anyway received the right fuse and tested the new fuse and it tests open continuity and did not fix my issue. Microwave is still dead. There are two other fuses in the back that i need to check so hopefully i find the issue. Hope this helps someone, remember one fuse behind the control panel tests open and the other tests closed and thats how it is suppose to function.
Parts Used:
Vent Thermostat
  • Jason from SHEFFIELD LK, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
Parts Used:
Monitor Door Switch
  • Ernest from RIVERSIDE, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken handle on door
Installed new handle with the two ordered screws. Everything fit. Quick repair. Though I believe the handle to be a little pricy.....when all is finished and all works properly one can overlook what ones feels is a little pricy. Also much cheaper than a entire new unit. Thanks for prompt delivery.
Parts Used:
Screw Tapping Screw Door Handle
  • Randy from Sandwich, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RVM1325BW02