Models > RS22ARXXW00 > Instructions

RS22ARXXW00 Roper Refrigerator - Instructions

All Instructions for the RS22ARXXW00
16 - 30 of 952
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Defrost timer was faulty. Required a mild tap to restart
Trouble shot the electrical circuit per the electrical schematic and zeroed in when I noted the Defrost Timer circuit was open. When I tapped on the bottom of the timer it began functioning normally (for a few days). Ordered a new Defrost Timer Kit and along with the installation instruction, I watched the on-line video. It was very helpful!!
After installation was complete, I plugged the Refrigerator into the electrical outlet and.......nothing happened! Hmmm!

Removed the Defrost Time Kit and inspected it for any damage and found none. Then I placed a flathead screwdriver to the manual advance knob and slightly rotate the gear mechanism. I heard a distance "click”. I believe the Timer was in the ‘defrost’ mode when received.

I reinstalled the timer, verified the wiring connections and this time plugged the Refrigerator into the electrical outlet and ….. it worked!!!

I unplugged the refrigerator, finished the installation per the instructions, plugged the unit in and monitored it for a few hours (just in case). That was a week ago and the Refrigerator is working like new.

The instructions were written in a manner which required re-reading a few times as they could be a bit vague. The video was what really helped and I appreciate PartSelect adding it to the instructions.
Parts Used:
Defrost Timer
  • LES from MADERA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
66 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker not initiating harvest cycle (not making ice)
My troubleshooting narrowed down the problem to either the control assembly or the thermostat, so I bought both just in case. The motor assembly fixed the problem and I didn't need to install the thermostat.

The main thing I want to tell others who are doing this repair, however, relates to the thermostat. If you do indeed need to replace the thermostat (#PS380941) there is something you will need that is not included with the part or mentioned anywhere on this site. The instructions with the thermostat indicate you need to apply something called "Aluminastic" to the thermostat when installing it. I don't know about you, but that isn't something I have around the house, so be sure to order a tube of it when you get the thermostat so you don't have to take a trip to the store to get it to finish the repair.
Parts Used:
Icemaker Control Assembly Cycling thermostat
  • John from Elgin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
66 of 74 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic broken around ice maker shaft
I removed the 4 screws from the inside front of the container that held the ice maker shaft in place. This allowed me to remove the old broken container from the front assembly. It was just a matter of attaching the new container to the front assembly and sliding the new container back into the freezer. I am back in business and I couldn't believe how easy it was to make this repair. Shipping was very speedy and communication was fast. I will use PartSelect.com again and refer family and friends for a good deal.
Parts Used:
Ice Container
  • Gary from Denham Springs, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
61 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Iced up, dripping water into refrigerator below
De-iced the refrigerator. Removed two screws from the thermostat panel on the upper refrigerator section. Tilted it down, removed two speed nuts holding the timer, unplugged the timer plug. Determined from the instruction sheet (easy to follow) what time delay function is used, based on wire colors, placed the jumper on the correct terminal on the new timer. Plugged it in, replaced the speed nuts and screws. The timer fit perfect, works just like it is supposed to, quick easy job.
Parts Used:
Defrost Timer
  • Robert from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
61 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Would Not Go On In The Refrigerator
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
Parts Used:
Light Socket Kit
  • DANIEL from MINNEAPOLIS, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
61 of 77 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken light switch
Took all the screws out of the plastic shroud that encloses the switch .There only four that I needed to remove, were the two in front where the switches that go,they go in horizontally and two in the back with large washers on them that hold the back to the top of the box that go in vertically.The switch was a snap ( make that two snaps ) the wiring is almost self explanatory. then it gos back to the way you took it off. OH! and don't forget to turn the light bulb all the way back in to the socket , so the light will work after you take the time to install it yourself.I had the water supply line from under the box to the water dispenser in the door and the total bill on that was one hundred thirty seven and a hand full of change.Don't be afraid to do it yourself the savings is enough on one one item to make several months payments on a new one Randy the "Handy Man'
Parts Used:
Door Light Switch
  • Randy from Hays, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
77 of 128 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
plastic Ice bin auger broke and needed to be replaced
The repair was actually easy; however I have an ice dispencer/crusher attached and the which the diagram supplied with the part did not include. I had to make several calls before I was e-mailed the diagram.
Suggestions: note that the screw at the end of the auger goes in the reverse direction (this took me about 20 minutes to figure out even though it was shown in the diagram). Also, be sure to keep the ice crusher parts in order and be sure the white plastic tab on the crusher fits into a depression in the housing. I did not notice this and had to take it all apart and redo the install. It works great!!!
Parts Used:
Ice Bin Auger Drum
  • Suzanne from Colorado Springs, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
54 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cooling would shut down and not restart until refrigterator was turn off and back on.
First I removed the cover plate over the cover over the thermostat, by snapping it out. Then I removed the four screws holding the cover over the thermostat in place. Next I removed the screw, which held the cover over the thermostat sensor. I then removed that cover and the unit, which exchanges air, flow between freezer and refrigerator. I then removed the two screws, which held the thermostat in place. I then removed the thermostat with the sensor and the white tube, which covered it. Then I removed the white tube from the sensor.

To install the new thermostat I first inserted the thermostat sensor into the white tub. I lubricated the sensor with a very small dab of Vaseline. Then I placed the sensor unit in the unit, which exchanges air between refrigerator and freezer. I next reinstalled the unit, which exchanges air between refrigerator and freezer. Then I reinstalled the cover over the thermostat sensor. I then installed the thermostat with the two screws, which held it in place. Then I reinstalled the cover the thermostat with the four screws, which held it in place. Last I snapped the cover plate in place.
Parts Used:
Thermostat Assembly
  • Michael from Oceanside, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
44 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Main Door wouldn't self-close
After removing all the food items from the door, I popped the plastic cover off of the hinge assembly located on the top of the door. With a fine point Sharpie pen , I marked the outline of around the hinge assembly so I could return it to original position. I then loosened each of the 3 bolts holding the hinge on just enough to allow me to clear the pin of the hinge out of the hole in the door. Once the top was free of the hinge, I lifted the door off of the bottom hinge/pin assembly. My cam parts on the bottom hinge and door were either broken and/or partially missing. I removed the broken and worn pieces by removing each of the screws holding the top and bottom (of the bottom hinge assembly) cam pieces and installed the new ones using same screws. I then reversed the steps and slid the bottom of the door back onto the bottom hinge assembly and then lifted the top hinge enough to allow the hinge pin to slid back into the hole on top of the door. Positioned the hinge so it matched the outline and tightened the 3 bolts. I checked the closing and made a slight adjustment to door as one of the shelves was hitting the interior as it tried to close. I did this by loosening the 3 bolts and pushing the door up and to the right (this door was on the right side of refrigerator). Tightened the bolts and reinstalled the hinge cover.
Pretty easy. My door cams were a little different so I didn't use all the parts in the kit. My shims were metal and did not move when I replace the cams so I didn't use anything in this repair except the 2 lower cam parts. I also put some grease/vaseline on the cams to lubricate them.
I figure the plastic cams just wore out over the years and all the heavy junk we put in the door shelves. I lived with this problem about 2 years before it donned on me that it was probably just a plastic piece or two that was broken or worn out.
Parts Used:
Door Closing Cam Kit
  • Gary from Huntington, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
43 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making ice
I removed the ice maker which required removing 3 screws and then disconnecting the electrical plug. Once the ice maker was out, I removed the 3 screws that held the motor assembly to the unit.
I removed the motor, replacing it with the new one.
Plugged the power supply cord back in, replaced the unit with the 3 screws and within a few minutes the unit was receiving water and by the next day I had ICE. This saved me $50. for the service call, then another $25.00 installation fee when the part came in (had to be ordered) plus the markup on the motor (approx. $25.00) So I saved approx. $100. and only took about 30 min.
Parts Used:
Icemaker Control Assembly
  • Dean from Pahrump, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
44 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water to ice maker not shutting off; overflowing
1. turn off power.
2. pop off ice maker cover to access motor assembly.
3. remove three screws to assembly.
4. pull off assembly.
5. attach new assembly making sure metal arm and plastic
ice tray rod align with assembly.
6. screw assembly onto unit.
7. replace cover.
8. plug in refrigerator.
9. enjoy ice again with no leakage into freezer.
Parts Used:
Icemaker Control Assembly
  • g anthony from salt lake city, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
43 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker did not make ice
The ice maker was not getting water. I hotwired the water valve by switching the connectors for the water dispenser and ice maker water valves and water flowed into the icemaker when the water dispenser lever was pushed. I wronly assumed the water valve was good. I removed the icemaker and determined that the gear motor was not getting power in the position the icemaker had stopped.In this position, the thermostat determines when the motor gets power so I replaced the thermostat. The icemaker still would not get water! As it turns out, the water solenoid was sticking due to a deteriorated rubber washer which let the solenoid plunger get too far out of the magnetic field. I replaced the water solenoid assy and all is well. Don't get fooled by hotwiring the valve. If it isn't getting water, the solenoid probably is the culprit.
Parts Used:
Cycling thermostat
  • DAVID from TINLEY PARK, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
47 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shut off arm broke
open ice maker door, use mirror to view slot in front of ice maker, slip piece in place and done
Parts Used:
ARM-SHUT
  • Thomas from Va. Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
52 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Ice, Water did not fill icemaker
We weren't sure if the problem was in the Water Inlet Valve or in the Icemaker Control & Motor Assembly. The water in the door did work. We removed the Water Inlet Valve & tested it with an Ohm Meter. It tested good so we put it back in. We then ordered the Icemaker Control & Motor Assembly. When it arrived we installed it and waited a few hours but the icemaker still did not fill with water. We telephoned a parts store and were told the problem could be the thermostat or we could replace the whole icemaker. We replaced the whole icemaker.
Parts Used:
Icemaker Control Assembly
  • Barbara from Davenport, IA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
45 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Timer "clicking", indicating worn gears
1. Unplug refrigerator to remove power!
2. The timer is inside the control housing located at the top of the refrigerator compartment.
3. Remove two control knobs (the pull off).
4. Remove the front panel escutcheon. The panel is not held in place with screws, but can be gently pried off.
5. Remove two screws from the back that hold the housing in place.
6. Remove screws from the front that hold the housing in place.
7. Drop housing down (still attached by wires - do not detach). Timer is inside housing, located on right.
8. Follow the instructions provided to identify your particular wiring setup. You'll find the wiring diagram (on my model) at the bottom of the refrigerator, alongside the defrost catch pan, behind the airflow grille.
9. Remove connector from timer terminals (4).
10. Remove two screws/nuts that hold the timer in place.
11. Install replacement timer following included directions. Read and follow ALL instructions applicable to your particular model and wiring setup.
12. Reassemble by reversing the steps above.
13. Note: You may need to "jog" the replacement timer when you first plug the refrigerator back in, if the timer happens to be in a "defrost cycle" (the compressor won't start). This can be done by inserting a wide bladed screwdriver into the hole below the timer, aligning it with the timer shaft, and slightly turning the shaft CW. Don't force it, and don't turn it very far.
Parts Used:
Defrost Timer
  • John from Plano, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
37 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RS22ARXXW00
16 - 30 of 952