Says bucket full when it was not
The forums indicate that one solution for this problem is replacement of the sensor assembly, which is what I did. Upon switching the sensor assembly it DID work for one bucket full, but then went back to indicating bucket full when it isn't. Other fixes indicate changing the switch assembly, which I tried to do but the part has been discontinued. The only other item is replacement of the main computer, which the cost added to the cost of the sensor assembly would equal the cost of replacement of the appliance, so I won't go there.
Parts Used:
Sensor Assembly
  • Thomas from NEWPORT, RI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Machine would come on for a minute, then stop with message CR1
Googled message to see that it was probably the sensor or the bucket full button. The bucket button is no longer made, but the sensor was available, so I gambled and bought it to try. We removed the outer housing and old sensor. then replaced new sensor putting it in same place and following the path of the old one to plug in wires. the whole housing had to be removed, could not just remove a section. Once replaced, plugged in to test, seemed to work. so replaced all the housing and screws. Unit is working again. Definitely worth the gamble, bc a tech would have been 3-4 times more expensive. My tenant was also confidant about being able to replace the sensor. After we did it, I think I could have done it too.
Parts Used:
Sensor Assembly
  • Judy from EVANSTON, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
turbo stopped spinning
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
Parts Used:
Turbo Fan
  • Cheryl from Bradner, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unit would not continue to run after start up. I was getting a 67 code on the humidity level screen
Ordered the new humidity sensor. Removed the sides and top all one piece of the dehumidifier by removing several screws. Removed the cover of the electric circuit box 2 screws. Removed old sensor by unplugging the wires. Installed the new sensor plugged in the 3 wires put the electric box cover back on. placed the sides and top back on screwed them in and it works just fine.
Parts Used:
Sensor Assembly
  • John from SHICKSHINNY, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller wheels
released broken wheels from their position using a screwdriver and secured new ones w/ a pliers.
Parts Used:
ROLLER
  • MICHAEL from LEBANON, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
N/a
We had no problem installing the product.
Parts Used:
PCB Assembly,Display
  • Scott from Wauseon, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 2 people found this instruction helpful.