old stand mixer mixing bowl base will not firmly hold newer mixing bowls
With a screw driver remove the screws holding the old base in place. With a flat head screw driver carefully pry and remove old mixer base. With 600 grit sandpaper clean and make smooth any burrs or rough spots in the mixer base recessed area. You can use some light grease and coat the outer edges of new mixer base and place in the now cleaned mixer base recessed area. The new base maybe a tight fit and not be fully seated in the recess. If a tight fit, place the piece of 2x4 piece of wood over the new part that is in the recess and carefully tap the base home using the sledge hammer. Check to see, if the base is fully seated. If not fully seated, tap again When fully seated replace the screws. You may have to adjust the height of the stand mixer head with mixer paddle attached for proper clearance between bowl and paddle. See your mixer manual for adjustment procedure
Parts Used:
-
Susan from BATTLE GROUND, WA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
pinion teeth sheared off the shaft
Repair went well after I figured out how to dis-assemble the mixer. Used straight & phillips screwdrivers and a small hammer & punch to drive out 3 pins. Ordered part# PS734233 pinion & shaft as shown in the parts page, it arrived on schedule, received part # 240210-2. Only problem was the new pinion had 10 teeth, the old/failed pinion had 11 teeth. Could not learn from anyone I called at PartsSelect or Whirlpool if the 10 tooth pinion was the correct part to use.
The teeth appeared to mesh with the mating gear,
installed the new pinion, reassembled and it worked fine. Not sure if it made a noticable difference in the output shaft speed.
The teeth appeared to mesh with the mating gear,
installed the new pinion, reassembled and it worked fine. Not sure if it made a noticable difference in the output shaft speed.
Parts Used:
-
Ray from Roanoke, VA
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Worm gear was stripped and needed to be replaced
I am not handy, but was able to follow this YouTube video and do this repair easily and successfully: https://www.youtube.com/watch?v=1QsgPIL9FpA
I did take the mixer apart first to verify that the worm gear was the issue, then ordered the part from you site. I received it quickly and was able to do the repair and get back to mixing in a few days!
I did take the mixer apart first to verify that the worm gear was the issue, then ordered the part from you site. I received it quickly and was able to do the repair and get back to mixing in a few days!
Parts Used:
-
Rachael from SEATTLE, WA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Mixer was making a loud noise and the attachment port was not working
-
steve from OWASSO, OK
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The original screw cap would not hold the mixer bowl in place anymore.
The new part was too large for the replacement job, but we used the self tapping screws that came with the mixer and screwed them in from the bottom to open the holes a little more since the original screws were to short to hold the new plate. Then we replaced the screws with longer screws and that seemed to do the trick!
Parts Used:
-
Sylvia from HILTON, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
worm gear worn out
I watched a short video on replacing the worm gear, although I did not know what the problem was until I watched the video. after the video ended I took the mixer apart and found the problem located a parts number an placed my order. got the part in one week put in the new part in about 20 minutes and it work like new. and the price was very reasonable
Parts Used:
-
michael from CISCO, GA
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Damaged insulation on the cord
Removed back cover, disconnected the 2 push-on connectors, removed ground wire screw. Reversed the process to install new cord.
Parts Used:
-
Dennis from WESTERVILLE, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stuck agitator shaft and dough hook
I had a sourdough batch get into the space where dough hook attaches and it got so stuck that nothing - not hot water baths, not pliers and screwdrivers got the dough hook released. I had to open up the mixer following partselect you tube instructions and replacing the parts. What was confusing to me at first is that my 45 year old mixer had an extra screw on top of the shaft that no longer is there for newer models. It took me longer than I am willing to admit to figure that the extra screw is not the result of me skimming the instructions - the original shaft and dough hook went to a friend who broke it attempting to disengage the two parts (the dough turned out to be a very strong form of glue!). The piece is working like new. I preferred the agitator shaft with a spring to hold the end piece tighter, but the new set up without a spring works just fine.
Parts Used:
-
Ana from PRT JEFFERSON, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cap screw was worn out and would not hold the bowl
-
Frank from Locust Grove, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Control stuck in high gear.
With the mixer being over 30 years old we believed it has going to have to be replaced. However, my husband jumped on uTube and looked at reviews for the problem. Motor was only running on high speed. Reviews said to replace the phase control board. Repair was very quick by just taking off the cover. Removing the old board and connecting the new. Mixer is working awesome once again. In such a disposable society it is great to be able to fix vs trash. Happy Baker.
Parts Used:
-
Ann from OSSINEKE, MI
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The threads on the plate that holds the bowl had stripped and the bowl flew off when mixing
Removed old plate, screwed in new plate and works like new! Was so happy I wouldn’t have to replace my 30 year old mixer.
Parts Used:
-
Christine from CHARLESTON, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The white enamel coating was breaking off the mixer beater. There was a scrapimg noise when the beater was in motion.
I simply inserted the new beater into the mixer to see if it scraped the sides of the bowl. It fit perfectly and didn't scrape the bowl like the old one did.
Parts Used:
-
Carolyn from LEXINGTON, SC
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bowl lock wouldn't hold when mixing bread
Repair is very straight forward. Remove the existing plate by removing the three phillip head screws. Use a regular screwdriver or knife to pop the plate off. (I cleaned the area while I was there but probably not necessary) Position the new plate with the screw holes lined up. Press down to pop the plate into position. Install original screws and tighten. You're done!
Parts Used:
-
John from COXS CREEK, KY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Mixer operarates at high speed only.
-
GALO from DECATUR, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Mixer went to high speed immediately on starting
Simple fix actually. UNPLUG mixer and remove the one screw on top that holds on the back. The Phase control board sits under and behind the paper insulator and "switch" assy. Remove the 4 wires with a pair of needle nose pliers, the one screw holding it to the back of the mixer and install the new one in reverse order.
Parts Used:
-
Michael from JACKSONVILLE, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!