uneven heating
Repair failed because part did not fit. Offset between top of element and contact prongs was too small, so element could not sit flat.
Parts Used:
Surface Element - 8 Inch - 220V
  • Dan from CHEWELAH, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original terminal degraded and faulty
Turn off power, remove heat coil assembly and drip pan. Unscrew the terminal assembly from the range top. Cut back 3 inches on each terminal wire and strip insulation 3/8 inch. Terminal assembly should be with the short side of the black block (from the side securement hubs) facing toward the coil stems. Slide the shrink wrap onto each wire and Twist each old with each new wire using the wire nuts and slide the shrink wrap Over each. Using a hair dryer, heat gun, or open flame carefully shrink the wrap. Secure the terminal back in place on the range.
Parts Used:
Terminal Block Kit
  • Robert from PRAIRIEVILLE, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
needed new drip bowls and 2 new elements
pulled them out and replaced them
Parts Used:
Surface Element - 8 Inch - 220V Chrome Drip Bowl - 6" Drip Bowl - 8"
  • kathy from DAVIS, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burner on stove stopped worker
I did as instructed on your video of how to install the terminal block, btw GREAT VIDEO!!
I'm a 66 year old female and if I can do it, anyone can.

Thanks, PartSelect
Parts Used:
Surface Element - 6 Inch Surface Element - 8 Inch - 220V Chrome Drip Bowl - 6" Drip Bowl - 8"
  • Virginia from MT PROSPECT, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
old drip bowls
replaced old drip bowls with new ones
Parts Used:
Chrome Drip Bowl - 6" Drip Bowl - 8"
  • Vera from Snow Camp, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Pulled the heating element on each burner installed the drip pans.
They fit perfectly for this stove. I had bought some drip pans but definitely not the correct pan. Saved time and about same at stores price. Great service thank you will order elements next. Pull heating elements remove drip pans and replace with new pans ,replace heating element. Done
Parts Used:
Chrome Drip Bowl - 6" Drip Bowl - 8"
  • Sharon from AURORA, MO
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
This is for a basic four-burner electric stove:One element was bent so I replaced it and all of the drips bowls needed replacing.
The element pulls out easily and slides right back in and the drip bowls just lift in and out. TaDa !!
Parts Used:
Surface Element - 6 Inch Chrome Drip Bowl - 6" Drip Bowl - 8"
  • Olivia from FAIRLEE, VT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Heating coils stop heating
Remove heating coils raise stove top unsrew terminal blocks cut wires assemble terminals strip wires twist wires together install wire nuts apply heat shrink lower stove top plug in stove repair complete.Thanks.
Parts Used:
Terminal Block Kit
  • Sharon from TEMPLE, GA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
2 burner elements not heating
Simple: Snip old terminal block off. Strip wires. Connect new Terminal block using twist-on wire caps (provided in kit). Mount to stove top with existing screw. TIP: Make sure you insert the wire lead into the terminal block the right way (not upside down). Otherwise burner element will not insert into terminal block properly.
Parts Used:
Terminal Block Kit
  • Brian from MENASHA, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Pitted, Eroded Drip Pans
1. First I pulled out the heating element from stovetop and removed old pan (no screws) very simple. 2. Put new pan in and inserted the heating element back in place.
Parts Used:
Drip Bowl - 8"
  • Josephine from Malden, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Left rear burner had a damaged burner prong.
I just had to plug the new burner plate in the receptical
and it works again very well.
Parts Used:
Surface Element - 6 Inch
  • Jackie from Charlotte, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Range burner coil worked intermittenly
Unplugged range and cut wires on existing burner plug. Connected the replacement plug with the provided wire-nuts. Secured with provided shrink-wrap. Reattached burner plug to to range top, and plugged in the burner coil. Presto.
Parts Used:
Terminal Block Kit
  • MARK from LIBERTY LAKE, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
rusty bowls
very easy
Parts Used:
Chrome Drip Bowl - 6" Drip Bowl - 8"
  • Monty from Kenton, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Intermittent heating element function
Instructions included with terminal block assembly. Toughest part was to strip the insulator off of the old wires on the stove. I was originally going to just purchase one but after looking at the other terminal blocks and seeing the burnt insulation and some of the wire strands, I just replaced all 4. PartSelect customer sevice was very helpful to confirm the correct part number I needed for my stove.
Parts Used:
Terminal Block Kit
  • Jeffrey from Pittsburgh, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Renewed drip pans
Replace the old ones with the new ones. Was VERY impressed with the quick delivery!!
Parts Used:
Drip Bowl - 8" Chrome Drip Bowl - 6"
  • Frank from Winter Garden, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!