Original gasket was not sealing properly. Appears to be original faulty installation
After receiving the part in the mail I removed it from the box and laid it flay on the floor. I had to use a hair dryer to CAREFULLY work it flat from the shipping. This took about an hour and a glass of scotch. I then let it sit over night to get the gasket as flat as possible. The next day I unloaded the freezer, unplugged it, and pulled the old gasket off by removing all the screws. I carefully slide the seal out of the track and did not remove the cover from the door. I left the door open for a couple hours to completely melt all of the ice and clean out the interior. I put the top and bottom of the seal in the track and carefully worked the sides in. It helps if you use a few screws to hold the gasket in place. Then easily pull the gasket to position it correctly. Using a screw gun with a clutch will help since there are quite a few screws. Check the seal by closing the door and see how it seals. It may be necessary to use the hair dryer to get the seal to pull up to the freezer body. Close the door and plug it it. Wait a few hours before putting in any food. Take your time and having a helper will make it go quicker.
Parts Used:
Refrigerator Door Gasket
  • Keith from BOSSIER CITY, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
Parts Used:
Run Capacitor
  • Andy from GOOSE CREEK, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
Evaporator Fan Blade
  • gary from ARANSAS PASS, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filter was dirty
Just push the button on the top right hand and pull the filter out; then proceed to instal the new one pushing it in place. It's really an easy operation!!
Parts Used:
Water Filter Base
  • Angel from Tampa, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace a bad door seal
Loosened the screws all around the door. easier if you take the door off the unit and lay it on a table. Cover the table with a blanket to protect the door finish. Old gasket just pulls loose. Press the raised bead on the new gasket under the plastic strip. Corners were the most difficult. Retighten the the screws and rehang the door. It took some practice to get the bead under the plastic strip.
Parts Used:
Refrigerator Door Gasket
  • Richard from Fairborn, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Wrench set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.

If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.

In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.

Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.

Hope this helps someone. :)
Parts Used:
BLADE-CONDENSER FAN
  • Jack from WALLING, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frost and ice build up/ gasket wasnt sealing properly
I did watch a repair a utube video which I asked for when ordering. Pretty much followed most of the directions but:

started in left corner an lossed all screws from left to right. took off old gasket in small sections and inserted the new gasket and semi tighten screws

proceeded down left side then right little by little as above. to get to bottom of door.

bottom corners were a little snug to get them into place. the last corner was snug but once connected. tighten screws not too tight. You dont want to strip them.

test door with piece of paper.

if paper is not a snug tug, you can adjust gasket with a hair dryer set to low.

it was easy. freezer is all set.

Partselect was great to deal with, support verified the part number was correct for my freezer and help with that video.
Parts Used:
Refrigerator Door Gasket
  • Richard from Warren, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door alarm going off indicating door ajar
This did not fix the problem. Call a repairman and he cannot come until 9/11. Food is staying frozen. Alarm sounds for awhile and then shuts off for a bit.
Parts Used:
Refrigerator Door Gasket
  • CONSTANCE from NEW COLUMBIA, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Copper lines leaking freon
Removed the inside evaporator coil to do inside solder job, use torch to heat solder joints on the outside drier in order to remove it and install new drier. Soldered Heat exchanger line to drier and 1/4” copper line to compressor. Wrapped with new insulation wrap. Pulled a vacuum on system and then charged with 4.4 ounces of 134a freon. Works like a champ again!
Parts Used:
HEAT EXCHANGER Filter - Drier
  • Mike from Jacksonville, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old gasket lost the magnetic seal,
We are not handy, we had an appliance repair person install the gasket.
Parts Used:
Refrigerator Door Gasket
  • Karen from W LAFAYETTE, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old part broke
The original part broke. The plastic attachment end of the part snapped off. The new part was easy to attach.
Parts Used:
Tall Bottle Retainer
  • W Howard from KEENE, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Filter would not seat without releasing itself.
Following previous installation instructions was very useful. Would add that the nut driver needs to be 1/4 in and to release the water lines from the valve body, simply squeeze the blue ring toward the valve and pull on the water lines at the same time. Simple fix!
Parts Used:
Water Filter Base
  • Lawrence from HUNTINGTON, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No problems
I had no problems. Screws arrived sooner than expected. It was a very simple installation. Very pleased with both the product and service.
Parts Used:
Screw
  • Nancy from LEHIGH ACRES, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The new motor mount screw holes were not threaded.
I had to tap the screw holes with a 8/32 tap so that the screws would not bind.
Parts Used:
BLADE-CONDENSER FAN
  • Greg from henrico, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loud noise fan blade broke,off balance
take 1/4 hex screws out clean out dust ,remove old fan blade replace with new install bolts .
Parts Used:
Evaporator Fan Blade
  • EDWIN from ELWOOD, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!