evaporator coil kept freezing up, refridgerator warm.
This was the second part I tried. The defrost timer was first, but that did not fix it. To do this I had to remove the ice maker and the back plate of the freezer. Then I defrosted the coil and cut the wires. stripped them back and installed the new thermostat. re-assembled and tested. has been working great ever since.
Parts Used:
Defrost Thermostat
  • Greg from Hanover Township, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
181 of 199 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not run but interior light was on.
I unplugged the refrigerator, then opened the door and removed four screws holding the plastic electrical panel to the interior top of the main refrigerator compartment and noticed the cold control was corroded badly, apparently from moisture in the panel. I ordered a new one from partselect.com. When it arrived the next day, I then pulled off the control knob, unclipped the cold control, unplugged the three wires to the control, then removed the styrofoam insulation blocks holding the thermocouple wire and then removed the thermocouple wire to complete the removal. I then reversed the process to install the new thermostat and control. That is repositioned the thermocouple wire, put the insulation blocks back to hold the wire, then replugged the three electrical wires, clipped the control back and pushed the control knob back on and finally screwed the panel back to the top of the main compartment and plugged the refrigerator electrical cord back in to provide current to the refrigerator. It immediately started up and ran fine. Total time - about 8 minutes.
Parts Used:
Cold Control Thermostat
  • Bruce from Alton, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
178 of 231 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold, not defrosting, refrigerator not cold
This was extremely easy. Took off the control box (housing that covers the light bulb, has the temp control dial on it) and easily replaced the defrost timer. Then, emptied freezer, took off cover at the back of the freezer. Disconnected old defrost thermostat, attached new one, reattached back cover, melted accumulated ice, put stuff back in. Started up. Been running great ever since. No more ice accumulation in freezer. Temp stays constant. Great service from PartSelect, saved lots of money. This job is easy on this fridge, go for it!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Mark from Tallahassee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
83 of 91 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Support rails holding meat tray drawer broke.
I removed the drawer from the support rails and placed it aside. I then removed the entire shelf that the rails were attached to. Each rail contained one (1) screw. I removed the screw, slid the support rails back approximately a 1/4 inch and they popped out. I replaced with the new rails, sliding them into place in reverse of how I removed the damaged ones & attached with the screw. I cleaned the shelf off and placed it back in the refrigerator, and placed the meat drawer onto the new rails. It actually took longer to clean the shelf than perform the repair.
Parts Used:
Meat Drawer Rail - Left Side Meat Drawer Rail - Right Side
  • Kathleen from Golden, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
57 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold. Fridge too warm.
Ice build up to back of freezer. Fridge way too warm for preserving food/drinks. Unplugged fridge and de-thaw freezer with a hair dryer. Removed and replaced defrost timer in the fridge area which simply unscrews and plugs in. The video supplied by PartSelect worked well for this.

The Defrost Thermostat required a bit more work as it is accessed through the freezer compartment. I had to remove two screws to get the back cover that houses the fan removed. Then you cut the wires from the old Thermostat and remove it before splicing in the new Defrost Thermostat using the supplied crimps and matching the wire colors. It is useful to have a good wire stripper/crimper ready to make the job simple (I bought a pro one for $28 at Home Depot but they can be found cheaper). Also, there is a bit of heat shrink material included to protect the wires from moisture so a heat-gun will do the trick or Good quality electricians tape will also cut it.

I then sparked it up and it works as new. :)
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Marc from Sumas, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
52 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Parts Used:
Defrost Timer - 60Hz 120V
  • Tad from Lancaster, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
46 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
Parts Used:
Light Socket
  • William from Alexandria, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
65 of 107 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door shelf/bin broke and fell off
I simply snapped in the new part. It took a few seconds. I would like to say that I found the part using the model number of the fridge. When I went to look at the description it said the part was 26 inches. The one I had was only 24 3/4 inches. I called you guys and was told that this was the correct part and to ignore the measuement.
You were Right! the part fitted perfectly.
Parts Used:
Refrigerator Door Shelf Bin
  • Phillip from Cary, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
45 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic frame broken
Lifted out old part, removed glass shelf and slid it into position in new frame. Reploaced the frame in refridgerator. Slid plastic storage bins into place. Job Done.
Parts Used:
Refrigerator Crisper Pan Cover
  • James from Owego, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
32 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wouldn't defrost
First, I replaced the defrost timer, really easy, 4 screws popped the cover of the electronic area (top of refrigerator compartment) took it out and plugged in the new time. Unit still would not defrost, so replaced the thermostat as well. Bit harder, removed ice maker, 2 screws, back plate from freezer, 4 screws. Thermostat was clamped to a copper tube- the original had one of the wires hanging out of it- cut the wires and crimped the new wires on, shrunk the plastic tube with blow dryer over the wires (taped them for good measure) and so far so good. Learned most of this through these tips, so keep reading if this isn't your problem, just save myself $1000 on a new refrifgerator...
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Patrick from Gansevoort, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
30 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken and cracked bins
Replaced the old bins with the new bins...The most important part of the story was finding this website and locating and ordering the necessary components...that was amazing - a few clicks of the mouse and my new parts were on their way.
Parts Used:
Dairy Door Refrigerator Door Shelf Bin
  • Ruth from Livonia, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
30 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Parts Used:
Defrost Timer - 60Hz 120V
  • Todd from pottstown, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.
Parts Used:
Defrost Timer - 60Hz 120V
  • Erle from Boise, ID
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light was out
Test the light socket first with a bulb that you know is good. If the light still does not come on, unplug the refrigerator, remove the switch by inserting a very small, thin, flathead screwdriver alongside it and pull the switch out slowly with your other hand. There are two wires there. Remove them gently with some needle nose pliers. If you want to test to see if the switch is defective, take a insulated jumper wire, and attach it between the two wires. Plug the refrigerator back in and see if the light comes on. If the light does come on, replace with a new switch by re-attaching the wires and placing it back in the hole firmly.
Parts Used:
Light Switch
  • andy from Peshastin, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
25 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Parts Used:
Defrost Timer - 60Hz 120V
  • Miles from Longview, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
22 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the DGHT2144KR0