Refrigerator to warm freezer ok
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Parts Used:
Defrost Timer
  • Christopher from Madison Heights, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Kickplate grille cracked
Pulled off cracked grille and inserted new in grille holders
Parts Used:
Refrigerator Kickplate Grille - Black Only
  • John from Georgtown, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Parts Used:
Dispenser Door Assembly or Flapper
  • D from ZELLWOOD, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Sherry from Auburn Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Leak From The Ice Make - Water All Over The Frig
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to identify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Parts Used:
Dual Inlet Water Valve
  • David T from Irvine, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water line leaking behind refigerator
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Michael from Merrimac, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
Parts Used:
Actuator Pad
  • Lowell H from Gilbert, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Parts Used:
Ice Maker
  • Cristina from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door hinge cam crumbled
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.
Parts Used:
Bottom Hinge Assembly
  • Ralph from Portland, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker door wouldn't open automatically
After replacing the solenoid several months ago, I concluded that the problem could only be the electronic circuit board that controls the timing and delay. The part arrived sooner than I expected. Installing it involved removing only six screws and unplugging two connections. The whole project took only about 10 minutes and now my ice maker works like new. Total cost was less than $55. Saved me several hundred dollars not to mention my personal time had I called in a repairman.

David O.
Albuquerque, NM
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • David from Albuquerque, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator door would no longer self close
Moved all items from door storage into refrigerator shelves. Removed top hinge cover held by single screw and top hinge plate held by two bolts. Lifted up door to clear bottom hinge pin and removed door. Covered open front of refrigerator with plastic wrap to keep cold in refrigerator with door removed. Laid door on kitchen counter top and removed bottom hinge assembly held on by two bolts. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door (helps to keep the three plates in same sequence and note the position of cam). Drilled out the rivet that holds the lower cam to the bottom hinge pin. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. Placed cover on upper hinge assembly and secured with original screw. Removed plastic wrap from front of refrigerator and moved the items that originally were stored in the door back to provide weight needed for door to close properly. All done and the door works like new, and all in less than 45 minutes. Would have been a more difficult job without the pioneering of people on this site. Thanks to all!
Parts Used:
Door Closing Cam
  • Melvin from Philomath, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the left drawer slide rail was broken from years of use.
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide.
I then used a phillips head screwdriver to remove the 2 screws that held the slide in place.
After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm.
The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
Parts Used:
Drawer Slide Rail - Left Side
  • Carlton from Chino, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was leaking water from the freezer section.
First remove all food from the freezer section, disconnect the power to the refrigerator and then remove all the shelves in the freezer.

Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.

After the panel is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.

Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.

Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.

Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.

Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.

Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!

P.S. Don't forget to put the food back in the freezer.
Parts Used:
Defrost Heater with Thermostat
  • Joe from Summerton, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
14 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
de light flasing on freezer door electronic disply
I removed the back wall panel inside the freezer compartment(approx. 6 screws). The coils were very iced up. I manually defrosted the the coils with a hand hair dryer. I then removed the 2 screws from each heater element and the clip-on thermostat from the coil. I pulled the elements, thermostat and wiring harness(item 230 on parts diagram) out of the freezer compartment and installed the new assembly. Electronic self-check of the defroster indicated normal. Further checks indicated the lower heating element was open.
Parts Used:
Defrost Heater with Thermostat
  • Sherri from Atlanta, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!