freezer cold but refrigerator warm, would not cycle the defrost on freezer
two screws and a connector were removed to replace the timer.
Timer was located on the top front of fridge
Parts Used:
Defrost Timer - 120V 60Hz
  • MATT from OAKLAND, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Parts Used:
Light Switch
  • Eileen from Coto de Caza, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve for ice maker leaking
Other than having to bend the bracket 90 degrees it was an easy install.
Parts Used:
Single Outlet Valve Kit
  • Randall from Cumming, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Wrench set
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would only make very small and very few ice cubes.
After determining that the ice maker on this relatively new refrigerator would make ice cubes if it received the proper amount of water. Ordered the valve and received in a couple days. Using a nut driver, removed the cardboard cover from the back of the refrigerator. Removed one screw holding the valve bracket to the fridge and removed another screw holding the water supply line and the water line to the ice maker in place. Pulled plug on fridge and removed 2 wires from valve. Removed inlet and outlet lines from old valve and reversed the process installing the new valve.
Parts Used:
Single Outlet Valve Kit
  • Margaret from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was leaking
thats what I did is remove the teo screws and took the old single outlet valve out. And put the new one in and put the screws back in. First turned off the water and put the water back on after I was threw and no leaks.
Parts Used:
Single Outlet Valve Kit
  • Phyllis from Minneapolis, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
a fan blade broken causing it to make a loud noise
we took off the old one and replaced it.
Parts Used:
Evaporator Fan Blade Kit
  • Marnie from Denver, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Parts Used:
Light Switch
  • paypal_shipping_address from Ripon, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Parts Used:
Light Switch
  • Jodi from Benton Harbor, MI
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking from bottom of refrigerator
I'm not a DIY-er, and wasn't sure a 20 year old refrigerator was worth the repair, but for $30 I could afford to be wrong. The swap is pretty intuitive, especially in my case since the problem was that the water tube from the valve to the ice maker had detached from the coupling. So I didn't have to cut anything off, just inserted the tube into the new valve. Reconnected the supply line, screwed the assembly back on the refer, and Bob's your uncle. Other than unloading some canned goods to lighten the refer, longest process was finding the right size nut driver in my disorganized tool tray. Be aware, there are NO instructions included with the part. Found a good video on you tube that confirmed the obvious. Glad I took a shot!
Parts Used:
Single Outlet Valve Kit
  • Bill from ORO VALLEY, AZ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator stopped making ice
Removed the old water valve from back of refrigerator by using a screwdriver. Pulled water line off old valve that runs into the fridge and inserted it into the new part. I used a pair of pliers to take off water line that runs into the water valve from the house. Screwed the water line back onto the new valve. Took about 10 minutes.
Parts Used:
Single Outlet Valve Kit
  • Doug from COPE, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan would not turn when the refrigerator came on all the time. Would physically have to turn the fan blades.
Did not do the repair because the unit arrived damaged. The packaging was in good condition. The plastic around the plug in shattered, and some of the plastic was inside the motor. Very good, and fast on adjusting the order.
Parts Used:
Condenser Fan Motor - 115V
  • David from CLIFTON, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water not being drawn up into icemaker
unplugged the old valve and disconnected the water line, then reconnected water line on new valve and plugged it in. It was an easy process but unfortunately that did not fix the problem. It is the ice maker it self so I will be ordering a replacement ice maker.
Parts Used:
Single Outlet Valve Kit
  • timothy from aberdeen, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
Parts Used:
Single Outlet Valve Kit
  • Cliff from ROCKVILLE, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Did Not Work
Tried replacing water valve since no water in ice cube tray. Exact part not available due to age of refrigerator, but I got the equivalent replacement part for $18. Mounting holes different, but I made it work. Also one connect on new one slip connect whereas both compression fittings on old valve. I put it back together and icemaker now works great.
Parts Used:
Single Outlet Valve Kit
  • Donald from Jacksonville, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water overflowing in ice cube tray
Remove the rear cover, shut off the water, removed the hose, unplugged the electrical connector, removed the screw holding the valve on. Removed the plastic tube going into the freezer and reversed the steps
Parts Used:
Single Outlet Valve Kit
  • Matthew from Sunland, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the BIS42CKC