Old timer quit working.
Installed the new timer.
Parts Used:
Defrost Timer - 120V 60Hz
  • John from Mesa, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer cold but refrigerator warm, would not cycle the defrost on freezer
two screws and a connector were removed to replace the timer.
Timer was located on the top front of fridge
Parts Used:
Defrost Timer - 120V 60Hz
  • MATT from OAKLAND, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer too cold and refrigerator not cold enough because fan not working
Had to defrost a bit and then was able to remove rear freezer panel by simply removing the 2 screws holding it in place.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and red wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Ann from LAPORTE, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original evaporator fan (31 years old) was making a lot of worn bearing noise
Empty freezer;
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.

I did have to use the wire extensions that were included as the replacement motor had the electric connections in a different location from the original motor.

Overall, this was an easy replacement.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • T from SOUTHBURY, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
RH side of vegetable drawer broke
Husband removed the broken one and replaced it with the new one ordered from you - all he needed was a screwdriver. Works wonderfully.
Parts Used:
Drawer Slide Rail - Right Side
  • Ida from Orange Park, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer too warm
1) This is a built-in refrigerator with the compressor, coils, etc. at the top. Turn off the breaker to the fridge. 2) Remove the front panel off the top (just push up and pull out). 3) Removed 2 screws to the old timer and carefully remove the plug. Plug the new timer in and screw in. 4) Since our fridge was heavily frosted up, we moved everything to another refrigerator and coolers and kept the refrigerator off until all panels were room temperature. 5) If you haven't cleaned the coil in a while, vacuum it with a soft brush attachment. 6) Turned back on and the refrigerator is cooler than ever!
Parts Used:
Defrost Timer - 120V 60Hz
  • Paul from Andrews, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
defrost timer was bad
repalaced the old one with the new one. easy
Parts Used:
Defrost Timer - 120V 60Hz
  • Reese from Coconut Creek, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer work refierator compartment is warm
Defrost timer is hidden in the control panel in the refrigerator top middle. Turn to off and remove two screws which are hidden behind white tabs. I had to pry the old timer from the plug with a screw driver because it was tight. Try not to short across the terminals. Plug in the new timer. Replace it in the clip where you got old one and reinstall the controls. The freezer was still all frosted up so I had to remove the cover and defrost it with a hair dryer to get it to work. Then I turned it on and it works great.
Parts Used:
Defrost Timer - 120V 60Hz
  • KIRK from Malibu, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Frezzer would freeze up, refrigerator stayed cold, solved the problem. Now the refrigerator seems to be running more than usual.
Checked the defroster coil which is located behind the rear panel in the freezer compartment, it was still working. Followed the schematics down to the defrost timer, which is located in the lower front of the refrigerator and tried that. Plugged in the new part and the problem is solved.
Parts Used:
Defrost Timer - 120V 60Hz
  • Henry from West Seneca, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?