Original gasket was not sealing properly. Appears to be original faulty installation
After receiving the part in the mail I removed it from the box and laid it flay on the floor. I had to use a hair dryer to CAREFULLY work it flat from the shipping. This took about an hour and a glass of scotch. I then let it sit over night to get the gasket as flat as possible. The next day I unloaded the freezer, unplugged it, and pulled the old gasket off by removing all the screws. I carefully slide the seal out of the track and did not remove the cover from the door. I left the door open for a couple hours to completely melt all of the ice and clean out the interior. I put the top and bottom of the seal in the track and carefully worked the sides in. It helps if you use a few screws to hold the gasket in place. Then easily pull the gasket to position it correctly. Using a screw gun with a clutch will help since there are quite a few screws. Check the seal by closing the door and see how it seals. It may be necessary to use the hair dryer to get the seal to pull up to the freezer body. Close the door and plug it it. Wait a few hours before putting in any food. Take your time and having a helper will make it go quicker.
Parts Used:
Refrigerator Door Gasket
  • Keith from BOSSIER CITY, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Piece broken off of drawer slide
I removed the screws and replace the broken slide with the new slide. Put the basket drawer back on the track and it now stays in place and can easily be used once again.
Parts Used:
Drawer Slide - Left or Right Side
  • Carol from Lawrence, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Parts Used:
Defrost Thermostat
  • Tunis from NOLANVILLE, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Missing key
After removing the key from its shipping package I pushed it into the freezer locking slot and turned it to lock and unlock the lid and then removed it. I had no problems with this fix. Of course, I am an older gentleman with a lot of experience in repairs around my house,as well as other houses. I am sure that a less experienced person may have more of problem with this type of "repair".
Parts Used:
Freezer Door Key
  • John from DUNBAR, WV
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would frost up and not get cold enough to keep frozen.
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Parts Used:
Defrost Thermostat
  • Richard from SLIDELL, LA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
End cap for side door shelf broken
Both end caps were missing on the door side bottom metal shelf. succesfully installed no tools needed
Parts Used:
Shelf End Cap - Right Side - Tilt-out
  • wissam farhat from medley, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It wouldn't restart when it turned off
I changed the cooling control
Parts Used:
Temperature Control Thermostat
  • Mervin from BOYD, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Parts Used:
DEFROST TIMER
  • Thomas from GRANBURY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No problems
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
Parts Used:
DEFROST TIMER Defrost Thermostat
  • Steve from PRAIRIEVILLE, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freeze would not re-start after temp rose above 23 degrees.
Unplugged the freezer. Located the Run Capacitor (next to the compressor). Removed the wire holding bracket, removed the Run Capacitor from the Start Relay. Installed the NEW Capacitor, re-installed the holding bracket. Plugged the unit in, looking at the display for the proper start-up sequence data. All is good - freezer operating for another 10+ yrs. NOTE: When removing the Run Capacitor, beware the COMPRESSOR could be HOT to the touch.
Parts Used:
Run Capacitor
  • Andy from GOOSE CREEK, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken drawer slide
removed old broken part, 3 screws, then installed new part.....done
Parts Used:
Drawer Slide - Left or Right Side
  • warren from Farmdale, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer stopped cooling
Used Phillips head screw driver to remove panel to expose old thermostat control. Took picture with phone to use and a guide. Replaced old with new and placed panel back o . Working perfectly! 30 minute max to complete.
Parts Used:
Temperature Control Thermostat
  • Scott from ROSTRAVER TWP, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
Evaporator Fan Blade
  • gary from ARANSAS PASS, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not stop running and had frosted over
Pretty simple, take cover off back of freezer to access thermostat, unhook thermostat and replace with new one. It had wire hookups different from original part so had to look up that information. Turned out it did not matter which wire went on which prong.
Parts Used:
Temperature Control Thermostat
  • marilyn from Dunlap, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan motor died.
Remove shelves. Unplug unit. Unscrew back panel. Remove wire harness. Remove old fan. Insert new fan. Screw it in. Reattach wires harness. Plug unit in and make sure fan is on.
Reattach back panel. Put shelves back in.
Parts Used:
FAN MOTOR EVAP 115V Basket Bumper
  • Yvonne from CORP CHRISTI, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the AFFU1766DW5