Icemaker producing few or no cubes and often leaving "kling-ons" on ice tray
Interior surface of ice tray felt rough & flaky (coating deteriorated) so cubes would not release.
Unplug appliance.
Remove timer cover by hand pressure @ edge.
Remove single attachment screw & bracket at lower front of icemaker.
Disconnect wiring harness from socket @ rear of compartment.
Tricky part was determining what type of connection held the other two attachment points along the long edge of the icemaker. I did not have repair manual or useful drawing but looked @ PartsDirect pic of side brackets & used a small mirror to confirm that mine were also some sort of "snap in" attachment.
Remove icemaker unit by pushing upward and outward on the unit. I takes a good bit of pressure and will pop loose, but be careful not to break attachment bracket from freezer wall.
Scavenge shut off bar and wiring harness from old icemaker once you have it out & attach to new one before installing it back in freezer.
Again, you might find a mirror useful to align those pesky snap-in brackets with the new unit.
Since you probably kept your freezer running while waiting for the part, the plastic snap-ins will be cold and brittle. I warmed them up first by applying a dampened cloth heated in the microwave to make them a little more pliable.
A good push of the new unit towards the snap-ins along with some upward force will get it stable.
Reattach the metal screw in bracket & connect the wiring harness to rear plug... and don't forget to plug the whole thing back in.
It will take awhile for the first batch of cubes dump as the timer may need to cycle completely around to get to the fill cycle... be patient.
Dump the first couple of batches of cubes just to make sure you're free of any residue.
Parts Used:
Replacement Ice Maker
  • Bernie from Diamond Bar, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
801 of 885 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer is cold, Refridgerator is not as cold as it should be
Having seen this problem before in other equipment so I had an idea where to look. Problem: the automatic defrost function was not operating. Looking through openings in the back panel of the freezer compartment, you could see the evaporator coils and fins were a solid chuck of ice. There are three logical components to check. Heater element, thermostat (located just above the evaporator) and a relay on the control board (located in the fridge control panel). Checked the heater with an ohm meter -- OK. The thermostat closes the circuit at around 20 degrees and opens at around 32 degrees. Pulled out the thermostat, wiring, fan unit. Everything unplugs, unscrews, and unclips, don't cut wires. Put the whole assembly in a friends freezer for an hour or so to see if the thermostat closes -- OK. Problem had to be with the control board. Replaced control board, reprogrammed it per included instruction. Everything is working again.
Parts Used:
Electronic Control Board
  • Russell from Hardinsburg, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
352 of 427 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowed ice maker turnning ice bucket into solid mass of ice
My ice maker has been shedding its non-stick coating for over a year. Within the last month of so, it started pouring water into the ice bucket below, turning it into a solid mass of ice. So I purchased a new ice maker assembly. I encountered two problems not mentioned in the 21 or so do-it-yourselfer repair stories that precede this one. First problem: one of the three screws that hold the ice maker to the refrigerator wall is hidden behind the large (black) end of the ice maker and is difficult to access. Before trying to replace the ice maker, make sure you have the physical dexterity to remove that screw. Second problem: it is not apparent how to remove the wire harness that plugs into the ice maker assembly. BEFORE you can remove the wire harness, you MUST remove the large white cap that covers the black end of the ice maker assembly and then push in a retaining tab to release the wire harness. If you don't do this, the wire harness will not release. Other than those two problems, it was relatively easy to remove three screws, unplug the wire harness, transfer three small, metal parts from the old ice maker to the new, plug in the new wire harness, mount the ice maker assembly so that the water tube is in the proper position, and then re-install the three screws. The ice maker works fine now. (P.S. I was told by an expert that the real problem might be a malfunctioning fill valve. I would have replaced the fill valve if replacing the ice maker assembly had not fixed the problem.)
Parts Used:
Replacement Ice Maker
  • Harry from Grand Ledge, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
269 of 364 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked & Snapped Center Crisper Rail
A very easy fix took all of five minutes
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Ruth from Roxbury, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
226 of 245 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defroster mode was not working causing freezer to ice up and refrigerator to be warm. Also fan was running continuely
The hard part for me was figuring out which part was causing the problem. I read what others had done and followed their test methods. I checked the defroster heater for continuity and the defroster thermostat to make sure it was closing. the defroster termostat has to be cold to check it. You will need to check it while it is in ice or take it out and put it in another freezer for 30 mins and then check it for continuity. Those items checked out ok so it had to be the control board. The control board is a 5 min job to replace but making sure that is your problem is the hard part. I think the control board was bad due to a power surge we had when the power went out and came back on. It might be a good idea to put a surge protector on your home to protect your fridge and all your other electronic stuff. Our refrigerator is now working like new again. Thank you for all your help, Jim
Parts Used:
Electronic Control Board
  • James from Welches, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
180 of 211 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was not getting cold and the coils were not defrosting.
Start by removing the freezer door and inner baskets so you have some space. Next, take out the ice maker by removing the 3 screws that attach it to the side and unplug it from the harness. Then the cover for the thermistor and the fan vent should be popped off carefully leaving the back cover only. The back cover is held on by 4 screws, one in each corner. Remove all 4 screws and carefully loosen the back cover by pulling the top forward and laying it level to pull it out. Behind the cover are the coils and other components. If the coils are covered with ice they should be defrosted by using a blow dryer. Once the ice is clear, the thermostat is located towards the top left clamped onto a copper pipe that circles up and around. Carefully pull it off the pipe and cut the wires making sure you leave enough to reattach the new ones with a butt connector. Strip about 1/4 inch of insulation off the wires and crimp both ends into the butt connector making sure they are tight. Heat shrink is highly recommended. Clamp the new thermostat to the copper pipe where the old one used to be and your almost done. Replace the back cover the opposite of the way it was pulled out by putting it in flat with the bottom part in front. Once it is all the way to where it needs to be, push the top upwards while sliding the bottom downwards, then push it in flat against the back. It can be bent slightly if needed. Put the screws back in that hold it on and replace the plastic covers. Then reinstall the ice maker being sure the hose for the water is correctly positioned so that the water goes into the ice maker. Turn it back on and put the baskets and door back on and you're done.
Parts Used:
Defrost Thermostat
  • Cheryl K from Pinellas Park, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
149 of 167 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Top unit was not getting cold
First thing to do is take two screws off where the door closes.I removed the light sheild off by pushing it to back of refrig.The most hardest part is removing the complete panel,I took a small flat blade scraper to ply down to get small access than you need to put alot of pressure to start getting the panel to start coming off there are alot of pegs to free,the back panel has two hinges that slide towards the front.Once the panel drops remove the connectors and take entire unit out,very easy to replace the control board at this point.Installation is easy slide the two hinges on back in place and put pressure on unit to snap entire unit in place.Program unit with paperwork that came with part very easy to do.Frig is working great now.Just a note the paperwork on refrig is located in the front right corner the mf hids it ,this information will allow you to check all problems with refrig using the key pads for freezer/refrig.Good luck.
Parts Used:
Electronic Control Board
  • Gregory from Lexington, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
144 of 163 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold, refrigerator warm
Overload relay accessible from back, by compressor unit. Very easy to change out. Diagram from your site placed defrost thermostat in same area.It wasn't. Found another diagram, showed it in refrigerator light area, took that apart, not there. Yet another diagram showed it in the duct work area at back of refrigerator cabinet. Not there. Finally removed back of freezer compartment, found thermistor and thermostat with the fins. Clipped wires, wired in parts, quick fix. Longest amount of time was spent finding the old parts to replace them. Actual replacement took less than 15 minutes. Refrigerator holding at 35 degrees set on 2 now, better than ever. Total cost, less than $120, doing iy ourselves....priceless.
Parts Used:
Compressor Start Device and Capacitor Defrost Thermostat Thermistor
  • Gordon from Ben Wheeler, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
177 of 282 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Parts Used:
Water Fill Cup and Bearing
  • David from Chester, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
107 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Parts Used:
Refrigerator Door Switch
  • Clint from Rayville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
118 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
not making ice
Installed new ice maker. It was easy - loosen two screws and unplug old wire harness. Put new unit in place. Did not realize new unit would not come with wire harness, but transferred old one to new ice maker (easy) and, "voila" some ice in 24 hours -- much ice since then. I am a 68 year old woman and it was "sort of fun" doing this job.
Parts Used:
Replacement Ice Maker
  • Pat from Dallas, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
77 of 91 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice in ice trey
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.
Parts Used:
Cycling thermostat
  • Wayne from Leesburg, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
78 of 100 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frig not cold at all,Freezer was all defrosted
Well the frist thing I did was get out the all the paper work and look under trouble shooting.This frig has a list of codes to try to help narrow down what parts might be bad.Well at frist it seemed it was a Defrost Thermastat?Well thanks to PartSelect it showed me right where it was and step by step how to remove and replace it.It took me over 2Hr's,after that I let the frig run all night and the next morning(yep warm frig)not the part I needed,well now Im mad,the local part store said you need a 3in1 jump starter easy to in stall at $50.Can'nt bring parts back no way weather thier opened or not.So get home and can'nt see how this jumper is going to wire up to my compresser?So on to the Web site to get some info,find out that this part gets a thumb's down,it puts out more volt's then needed and kills your compresser the reviews where very help full.So back to PartSelect to see more info,then I spoted the Overload/Relay and went to the back of my Frig and this part just plugs right into the compresser,I pulled it of with pliers and Bingo a burn spot melted right through the Overload/Relay.Ordered the right part the same as the old one.Put the part in and Bam,compresser fired right up.If I only did alittle more home work I could off saved alot of head ach and money.Thanks PartSelect I'll alway's click on to your web site for future parts and advise.
Parts Used:
Compressor Start Device and Capacitor
  • Denise from SOUTHINGTON, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
64 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Valve broke and was leaking
1. Unplugged fridge.
2. Unplugged wire harness from valve.
3. Disconnected water supply from valve.
4. Removed valve from fridge chassis
5. Removed plastic tube from valve (supplies ice maker).
6. Removed old fitting from plastic tube and attached to new valve.
7. Attached new valve to fridge (only need 1 screw)
8. Attached water supply to valve
9. Reattached wiring harness
10. Turned on water supply, checked for leaks
11. Powered on fridge.
12. Enjoy working ice maker.
Parts Used:
Single Outlet Water Valve
  • Chad from Gainesville, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
64 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cold but freezer was cold
removed ice maker and wire shelf. removed back panel screws and tilted forward. removed 2 screws holding motor bracket. swapped fan blade and reassembled
Parts Used:
Freezer Evaporator Fan Motor - 115V 60Hz
  • jarrett from PALM DESERT, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
65 of 79 people found this instruction helpful.