Models > 95-2162-00-00 > Instructions

95-2162-00-00 Tappan Refrigerator - Instructions

All Instructions for the 95-2162-00-00
1 - 15 of 172
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Fridge got warm and freezer coils were frosted
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.

Pulled plug.

Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be removed.

Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.

Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.

Removed old badly corroded thermostat.

I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.

Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.

Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.

Plugged back in and everying is working great!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Stephen from Warrington, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
336 of 400 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy fan
1. Removed the 7 nuts using the nut driver from the freezer back panel inside the freezer.
2. Remove the back panel. The evaporator motor and fan are located above the coils.
3. Unplug the wiring harness.
4. Remove the two gold mounting screws holding the motor and fan in place.
5. Remove the motor and fan including the brackets.
6. Install the new motor and fan onto the mounting bracket.
6a. Attach the green ground to the mounting bracket.
7. Screw the two gold screws back into the freezer.
8. Attach the new wiring harness. Note, the old harness had a mounting hole/space for it to connect to the wiring harness of the freezer. The new motor's harness was not long enough for this, so it is connected freely to the freezer harness.
9. Use the hair dryer to melt any ice that may have formed on the coils and hole where the fan goes.
10. Turn the freezer on to see if the fan turns on.
11. Reinstall the back panel.
All done!
Parts Used:
Evaporator Fan Blade Evaporator Fan Motor Kit
  • Jordan from Maumee, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
152 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Parts Used:
Defrost Timer - 60Hz 120V
  • Tad from Lancaster, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
46 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
Parts Used:
Light Socket
  • William from Alexandria, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
65 of 107 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator ran frequently and freezer door was sagging
I pulled off the old door gasket which came off really easy. I was hoping the new one would go on as easy as just popping it in place but it didnt work. I had to remove the inside door panel. The gasket wouldnt lay entirely flat in the inside groove so I used a bead of RTV around the entire circumference which helped to hold it in place while reattaching the panel back onto the door. The screws fit on the under side of the magnetic portion of the gasket. In order to access the screw holes the gasket has to be lifted which sometimes causes the gasket to pull from the lip on the back side of the panel making the RTV get everywhere. After every screw was in place and lightly tightened the panel had to be adjusted to allow for the proper closing of the door. This was the worst part, fortunatly the screws left a slight indentation of where they were before I removed them so it gave me a nice reference.
The hinge part of the new gasket requires a lubricant so it wont bind up when the door is closed. I didnt know about this until my order arrived and a part number was recommended for the type of lube. I just used Vasolene and it works fine.
The pin bearing was really easy. Just unload the contents from the door, mine was the freezer door. I popped off the cap covering the screws and removed the screws while holding the door so it wouldnt drop on the floor. Once off I used a flat head screwdriver to pry out the old one and a light tap of a hammer to replace it with the new. I put it all together the way it came off.
Now my fridge runs much less and the freezer door doesnt sag.
Parts Used:
Fresh Food Door Gasket Door Hinge Pin Bearing
  • Dale from Pevely, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
38 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Parts Used:
Defrost Timer - 60Hz 120V
  • Todd from pottstown, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Evaporator Fan Burnt Up
The fan motor all but caught the inside of the freezer on fire . Had to remove then clean, and I mean clean the walls of the freezer . Then had to pry out the old fan without breaking anything . Replacement of new fan was quick and easy because all the parts that I needed were in the bag
Parts Used:
Evaporator Fan Blade Evaporator Fan Motor Kit
  • ROY from PENSACOLA, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
28 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.
Parts Used:
Defrost Timer - 60Hz 120V
  • Erle from Boise, ID
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator portion would range in temperature from 30 degrees to 65 degrees every 24 hours, freezer would sometimes get warm
Removed the temperature control dial,took out the 3 screws that hold the cover for the thermostat and defrost timer, disconnected both the defrost timer and thermostat and replaced with new items. The refrigerator temperature has now been staple for one week.
Parts Used:
Cold Control Thermostat Defrost Timer - 60Hz 120V
  • John from Cedar Park, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
25 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge warming but freezer still frozen
I ordered a defrost timer and defrost thermostat from partselect.com. Parts arrived in 2 days (earlier than expected). Unplugged appliance, removed bottom cover, unscrewed 2 screws holding timer in place, unplugged timer and replaced with new part. Fastened back into place. Next removed back cover of freezer (5 screws using nut driver). Disconnected old thermostat and removed. Wires already had connectors installed. cut off the connectors with some wire left on and reconnected them to the new thermostat with the included blue wire crimps. Tried to use the shrink tube to insulate but couldn't get it snug enough. Just used electrical tape instead. Reinstalled thermostat. Reassembled cover. Plugged in and fridge and freezer are working fine again. Thanks partselect.com.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Todd from Thornton, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
22 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Parts Used:
Defrost Timer - 60Hz 120V
  • Miles from Longview, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
22 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side warm. Freezer was ok.
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and replaced unit. Works fine ever since.
Parts Used:
Defrost Timer - 60Hz 120V
  • Doug from Folsom, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster not working. Ice dams building up restricting cooling.
Not being sure which part it was, and having replaced the defrost timer already I changed all listed parts out. After 35 years they owed me nothing. I changed the control thermostat easily, I spliced in the defrost thermostat using the connectors and shrink wrap provided. The heater-defrosted element was a snap due to push/pull connectors.

Refrigerator is coopertone in color and matches the kitchen cabinets. oday the only viable option for a matching replacement is a subzero built in. Estimates for the cabinet work, subzero, electrician (to bring up to code) and plumber put the replacement at $12,000.

The unit is working like new with the replacement parts. I could have done more to isolate the faulty part but I think wholesale repacement was still a bargain.

I've fixed my Washing Machine and Drier with PartSelect parts and will continue to use them as my supplier.

Gregg
Massachusetts
Parts Used:
Defrost Heater With Straps Defrost Thermostat Cold Control Thermostat
  • Gregg from Milford, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
19 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
wonnt defrost
removed back cover from freezer to replace defrost stat. removed cover from refrigerator to replace defrost timer
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • bruce from grand haven, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer kept icing over, refrigerator too hot
First, I unplugged the appliance. Safety, first.
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the defrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Parts Used:
Defrost Thermostat
  • debra from new washington, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 95-2162-00-00