Models > 8ET15GKXJT > Instructions

8ET15GKXJT Maytag Refrigerator - Instructions

All Instructions for the 8ET15GKXJT
31 - 45 of 548
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
leaking around the valve
removed card board protection.4 screws. Unpluged refrigerator unscrewed the screw holding the valve but not all the way. disconnected the electric connection. removed the water connection after disconnecting the main water valve. replaced valve by reconnecting everything. Turned on water to check for leaks. Easy fix and recieved the part sooner then expected. Will highly recomend your fast service and correct part replacement. web site was easy to use. THANK YOU
Parts Used:
Single Outlet Water Valve
  • Russell from Westerville, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken cup water fill on ice maker
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.

Thanks,
Matt
Parts Used:
Water Fill Cup and Bearing
  • Matthew from Aurora, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lower left shelf support was broken
I removed all contents from the lower shelf. I, then removed both of the pull out drawers. Secondly, I removed the lower glass shelf and the glass support tray. At this point all four plastic shelf supports were accessible. I removed the inner screw from all four supports and replaced with four new shelf supports. Then reassembled in reverse order. Very easy to do!
Parts Used:
Crisper Drawer Shelf Support Screw
  • Michael from Torrance, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
21 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Single Outlet Water Valve would'nt shut off completely.
Start: UNPLUG THE REFRIGERATOR FROM POWER! Then -

1. Shut off water supply to ice maker.

2. Remove panel from back of refrigerator to expose single outlet water valve.

3. Disconnect water supply line from single outlet water valve.

4. Remove single outlet water valve from refrigerator (one screw).

5. Disconnect water line from the ice maker side of the single outlet water valve.

6. Reconnect the water line from the icemaker side of the old valve to the new single outlet water valve.

7. Re-attach the new single outlet water valve (with water line leading to the ice maker attached) to the refrigerator.

8. Reconnect the water supply line to the single outlet water valve.

9. Turn on the water and check for leaks.

10. Replace panel covering single outlet water valve at back of refrigerator.

Finish: PLUG THE REFRIGERATOR BACK INTO POWER.
Parts Used:
Single Outlet Water Valve
  • Harold from Oakton, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench set
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Parts Used:
Replacement Ice Maker
  • Harold from Oakton, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
18 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker leaked water
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Parts Used:
Replacement Ice Maker
  • Robert from Pennsylvania Furnace, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
didn't eject icecubes
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Parts Used:
Replacement Ice Maker
  • Ronald from Marion, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Parts Used:
Cycling thermostat
  • John from Rocky River, OH
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Refrigerator temperture unstable
My frig was cycling between upper 30's to 60 degrees, the freezer would make ice one day then be melting the next. I started by replacing the CONDENSER FAN MOTOR, relatively easy, unplug the motor, ratchet off the three supporting screws, splice the wires together, attach the ground wire and reinstall. That didn't seem to fix my problem.

I then ordered the Defrost Thermostat and Defrost Timer, based on past advice these were frequently replaced parts. Both installs were easy, the DEFROST TIMER was installed first, one screw holds the housing in the fridge, just unplug and unclip and install the new one. Very easy. This didn't seem to correct the problem overnight. I then installed the DEFROST THERMOSTAT, which was a couple of screws in the back of the freezer and uncip and install the new one. Very easy. This seemed to help the freezer maintain temperature, but the frig was still cycling up and down in temp on a daily basis and I had the temp knob all the way to 7 when it would normally work at 4.

I ordered the TEMPERATURE CONTROL ASSEMBLY. Easy to install, in the same housing as the Defrost timer, unhook some wires, reinstall and run the coiled part toward the back of the housing. This fixed the problem and has maintained my temp in the mid to lower 40's at the setting of 4.
Parts Used:
Temperature Control with Stabilizer
  • Alan from Brandon, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shelf bar end caps broke
slid new end caps onto bar and snaped back in to door. It took less than 1 minute.
Parts Used:
Shelf Retainer Bar End Cap
  • Donald from Taneytown, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 8ET15GKXJT
31 - 45 of 548