Microwave fan would come on when door open. Timer and unit would not switch on.
I looked up my problem on the internet and found a very helpful video. Microwave on video was different brand but the internals and methods were very much the same. The video made it simple and easy to fix. Found the replacement switch on the LG parts site and ordered. Two different switch types. One with red switch, the other green. Part was $7.28. Saved a bundle in service costs. Here is the repair video.

https://www.youtube.com/watch?reload=9&v=_AglBJoHgDs
Parts Used:
Micro Switch
  • Dick from SANDY, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan running with microwave door open
your part and YouTube video (which just happened to be my microwave)
changed bottom microswitch...done and dusted in 20 minutes...your $14 part 3B73362F saved $350!!!
Parts Used:
Micro Switch
  • BAKER, from BROOKLYN, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace resin cover in microwave
Used fingers to pull damaged cover away from microwave interior body. Used fingers to snap replacement cover into open slots.

Cover snap right into special slots.
Parts Used:
Cover,Resin
  • Paul from MCMINNVILLE, OR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave operated but did not heat
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Parts Used:
Fuse,Time Delay
  • Donald from Oak Ridge, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door handle was cracked.
Removed inside door covering partially with thin blade knife to see exposed handle screws. Removed screws, replaced new handle and replaced screws, then reassembled covering.
Parts Used:
Microwave Door Handle
  • Jerry from Phenix City, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
No Heat
1. Removed unit from the cabinet. (2 screws). 2. Remove the outer microwave metal shell. (10 screws). 3. Locate and remove part. (3 screws). 4. Install new part and replace all screws. 5. Install unit back into cabinet. So easy. I will share this site with all of my friends.
Parts Used:
Magnetron
  • Dennis from Chesapeake, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Microwave worked but did not heat
I removed the unit from under the cabinet and placed on a counter. I removed the metal covering. I then removed the defective part. The exploded views contained on the site were really helpful and instructive. I then put the unit back in place and powered it back up.
Parts Used:
Motor, AC Synchronous Magnetron
  • David from Cathedral City, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 72180593000