Models > 58632 > Instructions

58632 Refrigerator - Instructions

All Instructions for the 58632
16 - 30 of 672
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Parts Used:
Condenser Fan Motor Kit
  • robert from nashotah, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
37 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor "grounded" and quit running
Replaced the compressor with the new one I purchased from you. Installed new parts and recharged unit. The refrigerator / freezer is working better than new. Thanks for the great deal on the compressor. It was here in 3 days. All the parts fit exactly and had no difficulty in the installation or startup. The directions for the wiring were a great help also. Thanks again.
Parts Used:
Compressor Kit
  • Mike from Baytown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
59 of 118 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve failed, flooded kitchen
Turned off water supply and unplugged appliance. Removed lower panel on back of refrigerator with 1/4 " nutdriver. Then removed supply line, and line to icemaker. removed valve from back panel and replaced with new valve. wrapped water connections with teflon tape, turned on supply line, checked for leaks, everything o.k..Replaced back panel and in 45 minutes had first drop of ice. Job requires moderate mechanical ability and minimum tools. Saved a PANT load of money by doing it myself. VERY satisfied with Partselect.com
Parts Used:
Single Outlet Water Valve Kit
  • James R from Valley Springs, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
28 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both freezer and refrigerator section were not coled
First I did some research on the internet based upon the symptoms. Found several excellent articles that described my symptoms and their possible causes. I was able to isolate the problem to the thermostat by jumpering around the thermostat. In one scenario I was able to determine that the heater was working and in the other that the evarporator fan was also functioning. That left only one source and it was the thermostat. Ordered the part on-line and was happy to pay the extra shipping fee to expedite delivery. Sears was going to charge me $65 to show up and diagnose the problem. Parts and labor were then extra. What convinced me to look into fixing it myself was the week wait to have a repairman actually schedule an appointment. Two things - the internet is very helpful and Parts Select prices are very reasonable in comparison. Hopefully I will not have to fix anything else soon, but if I do, I will return to Parts Select for my part.
Parts Used:
Bimetal Defrost Thermostat
  • Kenneth from Eldersburg, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
30 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door cam worn out
remove top plastic cover / phillips screw driver
remove top door bracket / 5/15" socket
lift off door
remove pieces of old cam / phillips screw driver
replace cam/ phillips screw driver
replace door
replace top bracket / 5/16" socket
check alignment
Parts Used:
Door Closure Cam Kit
  • william from avon, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
27 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
Parts Used:
Water Fill Cup and Bearing
  • Jason from Austin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
32 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
Parts Used:
Refrigerator Door Switch
  • David from Albany, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
34 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Parts Used:
Condenser Fan Motor Kit
  • Janet from Hillsboro, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Parts Used:
Condenser Fan Motor Kit
  • Florentino from Windsor Locks, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Parts Used:
Replacement Ice Maker
  • Shelley from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
30 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Parts Used:
Condenser Fan Motor Kit
  • W from Nellysford, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Parts Used:
Condenser Fan Motor Kit
  • Bob from Hesston, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Parts Used:
Replacement Ice Maker
  • Kevin from Tyler, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator coils were freezing up and the water dispenser would not work
I was not sure what the fix was on my refrig, so I ordered the defrost timer kit, bimetal defrost thermostat, and the evaporator heater(about 100.00 in parts)
I think my entire problem was the bimetal defrost thermostat, as it was somewhat bulged out on the plastic side.
The evaporator coils would freeze over--the evap. fan would not work and the cold water dispenser would not work. I did't have time to just replace one part at a time so I ordered all three parts that have to do with the defrosting of the evap. coils.
The parts worked and the refrig. is operating fine. Thanks to parts select for a super fast delivery(one day).
Parts Used:
Bimetal Defrost Thermostat Defrost Timer Kit - 120V 60Hz Defrost Heater
  • Sammy from Clarksville, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator & freezer not cooling / freezing
First of all, I do not have a history of repairing appliances or even the knowledge of what all the parts are named or how it all works. That said, please excuse my other than technical explanation of the repair. After reading a few posts, I decided to order the two parts and give it a try. The Defrost timer was easy to remove - two screws to remove the housing and two screws to remove the timer. The bimetal defrost thermostat was an easy installation - after removing the cover plate (back of freezer section) I removed the two wire caps that was connecting the existing thermostat to whatever it connects to - I guess the heating element and ? I was a little confused because the replacement thermostat had more wires that the existing one. I decided to cut away the extra wires and connect it just like the old one was connected. I didn't work at first and I was about to call in a pro. I turned the defrost timer knob and everything started to work. It has worked beautifully since and I got to brag a little to my wife - that was short lived because she reminded me of the other "stuff" that needed to be fixed! Thanks to the folks that posted before me - it helped me understand the problem and the repair.
Parts Used:
Bimetal Defrost Thermostat Defrost Timer Kit - 120V 60Hz
  • Ken from Birmingham, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
20 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 58632
16 - 30 of 672