Freezer compartment iced over, food thawing,
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Parts Used:
Bimetal Defrost Thermostat
  • Lawrence from New Bern, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking water inlet valve
This would have been a less-than-5-minute repair except for one item. The water intake nossle was 180 degrees from the original part. As a result, the copper water inlet tube would not fit in the old space and still allow me to reattach the valve to the freezer chassie. I ended up leaving the valve hanging loose under the freezer. I spent most of my time trying to fit the valve into the old space.

Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.

Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished

Everything works just fine !
Parts Used:
Refrigerator Single Water Inlet Valve
  • Steven S. from Kerrville, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
Parts Used:
Bimetal Defrost Thermostat
  • Eric from miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Parts Used:
Defrost Timer
  • Thomas from Pottstown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator ran constantly and never got cold!
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever and I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Parts Used:
Defrost Timer Refrigerator Door Switch
  • Brandon from Fort Wayne, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
installed ice maker
From the time I started to finish I worked 3 hours, this included installing the new ice maker, cutting into the cold water line in the basement and installing a t with a 6inch piece of pipe with a compression valve to connect to the small cooper tube, this is worth your time to do it this way, its a lot better connection than the small pierce valves that come with the kit, they will leak over time. I installed the filter in the waterline in the basement for easy access
Parts Used:
ICEMAKER
  • Dennis from Spring Valley, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench set
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to the ice maker
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I sent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.

Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Parts Used:
Replacement Ice Maker
  • Ron from Ferndale, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not cycle
removed the defrost timer and replaced with new unit now i have a refrigerator again
Parts Used:
Defrost Timer
  • Maxine from Birmingham, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Parts Used:
Light Socket Kit
  • martin l. from JACKSONVILLE,, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken parts in refrigerator
Replaced with new parts
Parts Used:
Refrigerator Crisper Drawer Door Shelf Retainer Bar End Cap Trim Piece
  • Harald from Cape Coral, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I cracked mine :D
Slid right in...exceptionally easy :)
Parts Used:
Meat Drawer
  • Lisa from Fort Myers, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!