was not making ice
take out ice bucket, just loosen the top 2 screws, remove the bottom screw, slide ice maker up & out, srewdriver to release wiring harness clip, reverse to put back in. was very simple. did not install water inlet kit yet. water under fridge stopped after i changed the ice maker.
Parts Used:
Water Inlet Valve Replacement Ice Maker
  • GLENN from ORLAND PARK, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
696 of 775 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker quit working, I could manually cycle unit but then the water would overflow when unit was re-filling.
I backed out the 2 top screws about a quarter inch and then removed bottem screw with a quater inch nut driver. I then lifted Ice Maker clear of the two top screws and lowered it enough to unclip the power connection with a small screwdriver. The new Ice Maker was wired correctley for my refrigeator so all I had to do wea reconnect the power connection and mount new Ice Maker on the two top screws and install the bottem screw. It took e while for the new Ice Maker to start it's cycle but after it did, it worked GREAT. Part Select service was OUTSTANDING, ordered part one day and received the next. THANKS!!!!
Parts Used:
Replacement Ice Maker
  • Max from Green Castle, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
584 of 619 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
Parts Used:
Icemaker Control Assembly
  • Daniel from Suwanee, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
557 of 665 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Front Door Ice Wouldn't Work And Air Going Into Freezer
Thanks to the pictorial diagram, I was able to order correct parts. It was just a matter of removal of broken parts and replacing them. Ice maker now working and air is no longer getting into freezer which was freezing up ice maker. Thanks for timely delivery, now I am able to use ice dispenser, which I haven't used for long time. Thanks
Parts Used:
Ice Door Kit Dispenser Door Pin Control Bracket Micro Switch
  • BILL from BATESVILLE, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
492 of 591 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator door was not closing all the way if not pushed shut.
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Norbert from Sugar Land, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
392 of 413 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Parts Used:
Capacitor
  • garth from forest lake, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
393 of 473 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
inconsistent compressor and condensor fan operation
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...
Parts Used:
Thermostat Assembly
  • Steve earney from Brooks, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
305 of 320 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When the remote water was turned on, water was pouring onto floor from rear of refrigerator
First I unplugged the fridge, then using the socket set I removed the cardboard shield from the lower rear of the refrigerator. I located the leaking water from a cracked solenoid water valve just inside the lower cavity directly behind the water intake line. Removing the valve was a snap - most of the valve plastic compression couplings unscrewed and came off. The metal compression fittings required an adjustable wrench and a pair of pliers to hold the solenoid unit steady. A couple of hex nuts kept the solenoid bolted to the refrigerator frame and came off easily with the socket. Two simple push-on electrical plugs came right off just by pulling on them. The new valve unit wasn't exactly like the original one. It had push-on instead of compression water fittings and the plugs were oriented differently. I recommend studying which water lines entered which port on the valve because I was a little unsure after I took the old one apart (whoops). After figuring out how to put it pack together, the push-on water fittings were even easier, and the unit was scewed back into place on the fridge frame. The electric plugs have different sized contacts so you can't mix them up. I put the cardboard shield back on. Viola!
Parts Used:
Water Inlet Valve
  • Mark from Wolfeboro, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set, Wrench (Adjustable)
214 of 248 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both freezer and refrigerator stopped cooling
Compressor Start Divice kit, I took off back lower panel with the 1/4 inch nut driver, on the compressor their was a wire hook that held the starter in place used my plyers to unhook, pulled the unit off plug the new unit in reappled the clip it was so easy I had to exame it severl to time to make sure that was all their was to it. put the cover back on and turn the refrigerator on and it has work great, I did not install the Bi-Metal Defrost Thermostat it was not needed.
Parts Used:
Bi-Metal Defrost Thermostat Compressor Start Device Kit
  • Laune from Front Worth, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
224 of 281 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Seven year old condenser fan was making noise when it was running.
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.
Parts Used:
Condenser Fan Motor Kit
  • Josue from Jacksonville, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
199 of 210 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic bits dispensed from Ice Dispenser in Door
Removed Ice bin from Fridge

Removed all bolts on bin with nut driver...about six

Removed housing...be careful with spring on crusher/cube control rod

Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.

Removed plastic nut on end of auger shaft

Removed Ice crusher jaws and laid them out in the correct order

Removed Ice propeller and installed new part

Put back together in opposite order

Easy
Parts Used:
Ice Bin Auger Drum
  • john from seaford, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
202 of 237 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Ice in the Ice Maker
I am NOT a handyman, and my family laughed at me when I said I was going to fix the ice maker all by myself. I ordered a replacement ice maker. When it arrived, I opened the box and read the instructions. It seemed easy. I removed the old ice maker, with a socket set. I then took off the shut off lever from the old one and placed it on the new one, since the new one didn't come with it. I then put the new one in place. All the parts fit perfectly. The ice machine was making ice within an hour. My family was amazed... and I got the last laugh!
Parts Used:
Replacement Ice Maker
  • Chris from Duluth, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
195 of 224 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Clicking from underneath the fridge, and compressor engaging only intermittently
I diagnosed the problem as a bad relay. I detached the two sets of wires leading to the relay and compressor, then pulled the relay off the compressor. It rattled and small bits of detritus fell out from inside of the relay. The new relay came the next day. It did not rattle. It was identical and I simply did the reverse to reinstall.
Parts Used:
Compressor Start Device Kit
  • Michael from Manvel, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
198 of 239 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
External Ice Guide Broke a Tooth and Fell Off
We waited two years to do this because we didn't want to hassle with a repair man to come out and charge us arm+leg for something so simple. Finally we searched and found the part on line. It came two days FASTER than promised. Kudos to Part Select.
Snapping it on was a breeze, although you do have to apply more pressure than feels comfortable with plastic clips. We can know get ice out of the external door system again.
Parts Used:
Ice Guide
  • Tracy from Jacksonville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
170 of 186 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would't fill with water
I first read your forum which was extremely helpful! I checked the continuity of the electromagnetic valve and got a 0 reading on the ice fill valve. The valve next to it which is for the water in the door had a 300ohm reading on my meter. This meant there was a broken wire somewhere in the coil which confirmed the valve was bad. I tried to get the part locally but was told it was on back order! Ordered it thru Part Select at the regular shipping rates and to my surprise it arrived the very next day!
The valve was the new style where you push in the tubing until it locks. I carefully trimmed each tube square with a sharp razor knife, the old valve used plastic compression fittings which had to be cut off.One of the inlet tubes was smaller than the opening on the valve. I then noticed that there was a reducer in the box that snapped into place making the line a perfect fit! Even though the inlet valve looked different than the original it was an easy installation. After replacing it, I had ice again! Totally impressed with the service and how quickly they shipped the parts on the same day! I will never again run around town trying to find parts! Thanks to all of the hard working employees at Part Select!
Parts Used:
Water Inlet Valve
  • Jerry from Cooper City, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
167 of 183 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10652524101
1 - 15 of 1637