Replacing still working but old and stained levers
The overflow grille was no problem. It just slides out. To get to the levers, you need to remove the front cover trim. Pay attention to where everything is before you remove parts and how the wiring is set up (over or under parts). There are two slots below the trim, use your blade screw driver and pop the trim. You'll notice that the 4 buttons for ice (crush - cube) and the light (off-on) are on that panel. I don't recall well, but I believe two screws (one at each side) hold that part in place. Once loose, I flipped it up, disconnected the white multi- wire quick connector and used duck tape to tape the panel to the door and keep it out of the way. Another screw keeps the levers in their place, with a metal element. Remove it and the levers will come out. The ice guide just snaps out from two sides and a middle plastic hook of the ice dispenser lever. Replace everything in reverse order. That's about what I remember. Hope it helps.
Parts Used:
Water Dispenser Lever - White Ice Dispenser Arm - White Dispenser Grille Ice Guide
  • Mario from Oklahoma City, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
55 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken shelves
replaced with new shelves
Parts Used:
Crisper Cover with Glass
  • Maria from Albuquerque, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
60 of 88 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator too warm, freezer coil iced up
Unplug the refrigerator first,then Remove shelves and back inside cover from the freezer. Cut old bi-metal thermostat off and installed a new one. This fixed the problem. Ordered a new timer also which I didn,t need but installed it any way. On the fridge side ,top front, removed the knobs and cover, R&R timer, installed cover and knobs. Pay close attention to the instructions on where to put the black wire on the new timer. My refrigerator works great now. This was easy to repair if you are handy with electrical and mechanical repairs, if not get some help.
Parts Used:
Bi-Metal Defrost Thermostat Defrost Timer
  • Jim from Lynn, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
52 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispenser would not operate
The control bracket is made of plastic and holds two microswitches that activate the ice dispenser and the water dispenser. The plastic clips that held the switches on the control bracket broke so that the switches no longer operated when the ice dispenser lever was operated.

Two screws held the external dispenser bezel, and two screws held the control bracket in place. The wiring and switches were transferred to the new bracket and the new bracket screwed into place. Then the bezel was replaced.

Total repair time was less than 5 minutes. The control bracket was $16.50 with shipping and arrived two days after I placed the order.

The PartSelect website had a clear diagram of the control bracket so I was comfortable with the order.
Parts Used:
Control Bracket
  • John from Poway, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
46 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door was making a clunking noise
The door is very easy to remove. There is one nut for the cap on the top of the soor hinge. Once the cap is removed, you need to remove the 3 nuts holding the hinge in place. Simply lift the door off the lower hinge and rest it on the dining room table. I set towels down to protect the stainless finish. The closing cam will be visible on the bottom of the door. I choose to replace the lower cam and the upper cam at the same time. I did not know what the problem cam was. The door works good as new. I put a small amount of vaseline where the two cams rub to provide a lubricant.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Erik from Yorba Linda, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
46 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cooling would shut down and not restart until refrigterator was turn off and back on.
First I removed the cover plate over the cover over the thermostat, by snapping it out. Then I removed the four screws holding the cover over the thermostat in place. Next I removed the screw, which held the cover over the thermostat sensor. I then removed that cover and the unit, which exchanges air, flow between freezer and refrigerator. I then removed the two screws, which held the thermostat in place. I then removed the thermostat with the sensor and the white tube, which covered it. Then I removed the white tube from the sensor.

To install the new thermostat I first inserted the thermostat sensor into the white tub. I lubricated the sensor with a very small dab of Vaseline. Then I placed the sensor unit in the unit, which exchanges air between refrigerator and freezer. I next reinstalled the unit, which exchanges air between refrigerator and freezer. Then I reinstalled the cover over the thermostat sensor. I then installed the thermostat with the two screws, which held it in place. Then I reinstalled the cover the thermostat with the four screws, which held it in place. Last I snapped the cover plate in place.
Parts Used:
Thermostat Assembly
  • Michael from Oceanside, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
44 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Excessive noise was coming from the freezer section of my side be side refrigerator
Cleaning out the freezer took the longest time. Once the freezer was clean I turned off the freezer which did not deactivate the light in the freezer. This is a tight area to work in and not having to hold a flashlight made the job much easier. I then removed the shelf slider brackets for the 3 lower pullout drawers. The next step was to remove the interior aluminum back panel (6 screws) which covers the evaporator motor and the coil. Before removing the 3 electric wires that are attached to the evaporator motor make sure the power is off to the motor. The removal of the motor was fairly straightforward and I would suggest removing the plastic fan blade first and then the connector wires. It helped knowing in advance that the plastic fan blade would come off with a little prying. Be careful when prying the fan off so that you don’t damage the plastic motor mount bracket. Once you have installed the motor I would suggest turning the freezer back on to make sure that the evaporator motor works before reinstalling the aluminum back panel and slider brackets.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Jon from Houston, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
43 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Believed the condensor motor was defective and causing strange odor
First disconnected the quick release electrical connection. Then loosened the three screws that were holding the motor in the bracket. However, space is limited and even with small hands it was rather difficult as the screws were in there very tight. There are a few sharp edges on the bracket and in the surrounding area of the motor area, and nicked myself a couple of times. Removed the fan blade from the old motor and attached it the new motor with the old flat washer/screw. Reconnected the electrical connection and that was that. All-in-all an easy repair.
Parts Used:
Condenser Fan Motor
  • Nicholas from Frankfort, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
45 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice door was broken
1) At bottom of ice maker trim there are two small slots at right and left ; use screw driver to pry away from door; lift trim upward away from door 2)using 1/4" nutdriver remove screws from 4 corners, 3) remove 2 screws from control panel 4) disconnect all wires/cables and set exterior panel aside. 5) locate 2" pin that runs through door spring and use needle nose pliers to remove round clip on left end of pin don't lose this clip 6) while pushing ice maker lever (where you would push with your glass) use needle nose to pull the long pin out to the right 7) Remove all remaining parts by hand (i.e. the pin, the dash pot and white lever and the ice door) 8)slide new control lever into slots on exterior side of the new door 9) -tricky part- using needle nose, push pin back through the right hinge point, the new lever, the new door, the new spring and the left hinge point (note the new door has no electric wire connector) 10) using the needle nose, carefully replace the little round clip on the left end of the metal pin. 11) reconnect all the wires (don't worry about the wire that had been connected to the door wire, just fold it aside) 12) replace two screws screws in control panel and four screws at corners of exterior panel 13) snap outer trim panel back in place.
Parts Used:
Ice Door Kit
  • Ray from San Antonio, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
46 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making ice
I removed the ice maker which required removing 3 screws and then disconnecting the electrical plug. Once the ice maker was out, I removed the 3 screws that held the motor assembly to the unit.
I removed the motor, replacing it with the new one.
Plugged the power supply cord back in, replaced the unit with the 3 screws and within a few minutes the unit was receiving water and by the next day I had ICE. This saved me $50. for the service call, then another $25.00 installation fee when the part came in (had to be ordered) plus the markup on the motor (approx. $25.00) So I saved approx. $100. and only took about 30 min.
Parts Used:
Icemaker Control Assembly
  • Dean from Pahrump, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
44 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice, water to dispenser OK
Originally replaced water inlet valve, not the problem. Tried to work from cheap to expensive.
1. Turn off power, shut off water supply
2. Loosen top two screws of ice maker (will slide up and off, no need to take top two out)
3.Remove bottom screw from ice maker
4.Pulled unit, snapped out existing wire harness
5.Cut hole for water inlet on end of new unit and attached wire icemaking on/off bracket.
6 Connected existing wiring harness to new unit
7. Slid new unit down onto top two screws, put in bottom screw and tightened all three
8. Turned on power and water supply
Had ice being made within two hours. Part Select has given me great service, highly recommend.
Parts Used:
Replacement Ice Maker
  • Mike from Myrtle Beach, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
44 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water to ice maker not shutting off; overflowing
1. turn off power.
2. pop off ice maker cover to access motor assembly.
3. remove three screws to assembly.
4. pull off assembly.
5. attach new assembly making sure metal arm and plastic
ice tray rod align with assembly.
6. screw assembly onto unit.
7. replace cover.
8. plug in refrigerator.
9. enjoy ice again with no leakage into freezer.
Parts Used:
Icemaker Control Assembly
  • g anthony from salt lake city, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
43 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker stopped working due to defective timing gear
I removed two screws on the top and one underneath the unit. Then I disconnected the cable. The hardest part was getting the nut driver on the bottom screw because it was obscured by the unit. The replacement unit plugged right in! I got my first batch of ice in about 20 minutes. All I really needed was the timer unit, but the entire ice maker wasn't much more expensive, especially when you consider the time saved on installation!
Parts Used:
Replacement Ice Maker
  • Nicholas from Boca Raton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
42 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker did not make ice
The ice maker was not getting water. I hotwired the water valve by switching the connectors for the water dispenser and ice maker water valves and water flowed into the icemaker when the water dispenser lever was pushed. I wronly assumed the water valve was good. I removed the icemaker and determined that the gear motor was not getting power in the position the icemaker had stopped.In this position, the thermostat determines when the motor gets power so I replaced the thermostat. The icemaker still would not get water! As it turns out, the water solenoid was sticking due to a deteriorated rubber washer which let the solenoid plunger get too far out of the magnetic field. I replaced the water solenoid assy and all is well. Don't get fooled by hotwiring the valve. If it isn't getting water, the solenoid probably is the culprit.
Parts Used:
Cycling thermostat
  • DAVID from TINLEY PARK, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
47 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shut off arm broke
open ice maker door, use mirror to view slot in front of ice maker, slip piece in place and done
Parts Used:
ARM-SHUT