inconsistent compressor and condensor fan operation
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...
Parts Used:
Thermostat Assembly
  • Steve earney from Brooks, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
305 of 320 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator door was not closing all the way if not pushed shut.
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Norbert from Sugar Land, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
392 of 413 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Parts Used:
Bi-Metal Defrost Thermostat
  • Cathy from Winter Park, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
154 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Door quit closing on it's own......
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • T.w. from Batesville, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
140 of 153 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. Works great now and i have ice everyday :)
Parts Used:
Thermostat Assembly
  • michael from clarksville, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
116 of 121 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator fan stopped working
1) removed the face plate that runs 3/4 way up the back of the freezer side. a total of 8 screws. (6")
2) disconnected the three electrical connections.(30sec)
3) removed the fan of the the old evaporator fan motor (5sec)
3) removed the fan motor (1")
4) put in the new fan motor (1")
5) put on the old fan on the new fan motor(5sec)
6) reconnected the three electrical connections (30sec)
7) replaced the face plate on the back of the freezer (6")
Had re-frozen meat within 1 hour.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Antoni from vail, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
95 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Parts Used:
Refrigerator Door Switch
  • Clint from Rayville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
118 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling properly.
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "
Parts Used:
Thermostat Assembly
  • Eddie from Gretna, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
73 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wanted to install ice maker in my freezer
I was clening my uprght freezer and noticed that it was preped for an icemaker. I first went to the Whilpool website and could not find my part as my freezer was a 2008 model.

I saw PartSelect on the search page and went to thier site.
I put in my modle number of the Whilpool Ice maker kit that was on the back of my freezer. PartSelect had the part in stock and approx $18.00 less than the other kits listed on the Whilpool site (that did not match my kit number). I orderd the kit on Sunday and it arrived on Wednesday. It took less than and hour to install. Every part I needed was included. The following day I installed the water line and now I have an extra icemaker.
Parts Used:
ICEMAKER
  • Donald A. from ORLANDO, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
74 of 105 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Would Not Go On In The Refrigerator
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
Parts Used:
Light Socket Kit
  • DANIEL from MINNEAPOLIS, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
61 of 77 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken light switch
Took all the screws out of the plastic shroud that encloses the switch .There only four that I needed to remove, were the two in front where the switches that go,they go in horizontally and two in the back with large washers on them that hold the back to the top of the box that go in vertically.The switch was a snap ( make that two snaps ) the wiring is almost self explanatory. then it gos back to the way you took it off. OH! and don't forget to turn the light bulb all the way back in to the socket , so the light will work after you take the time to install it yourself.I had the water supply line from under the box to the water dispenser in the door and the total bill on that was one hundred thirty seven and a hand full of change.Don't be afraid to do it yourself the savings is enough on one one item to make several months payments on a new one Randy the "Handy Man'
Parts Used:
Door Light Switch
  • Randy from Hays, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
77 of 128 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door was making a clunking noise
The door is very easy to remove. There is one nut for the cap on the top of the soor hinge. Once the cap is removed, you need to remove the 3 nuts holding the hinge in place. Simply lift the door off the lower hinge and rest it on the dining room table. I set towels down to protect the stainless finish. The closing cam will be visible on the bottom of the door. I choose to replace the lower cam and the upper cam at the same time. I did not know what the problem cam was. The door works good as new. I put a small amount of vaseline where the two cams rub to provide a lubricant.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Erik from Yorba Linda, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
46 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cooling would shut down and not restart until refrigterator was turn off and back on.
First I removed the cover plate over the cover over the thermostat, by snapping it out. Then I removed the four screws holding the cover over the thermostat in place. Next I removed the screw, which held the cover over the thermostat sensor. I then removed that cover and the unit, which exchanges air, flow between freezer and refrigerator. I then removed the two screws, which held the thermostat in place. I then removed the thermostat with the sensor and the white tube, which covered it. Then I removed the white tube from the sensor.

To install the new thermostat I first inserted the thermostat sensor into the white tub. I lubricated the sensor with a very small dab of Vaseline. Then I placed the sensor unit in the unit, which exchanges air between refrigerator and freezer. I next reinstalled the unit, which exchanges air between refrigerator and freezer. Then I reinstalled the cover over the thermostat sensor. I then installed the thermostat with the two screws, which held it in place. Then I reinstalled the cover the thermostat with the four screws, which held it in place. Last I snapped the cover plate in place.
Parts Used:
Thermostat Assembly
  • Michael from Oceanside, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
44 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Believed the condensor motor was defective and causing strange odor
First disconnected the quick release electrical connection. Then loosened the three screws that were holding the motor in the bracket. However, space is limited and even with small hands it was rather difficult as the screws were in there very tight. There are a few sharp edges on the bracket and in the surrounding area of the motor area, and nicked myself a couple of times. Removed the fan blade from the old motor and attached it the new motor with the old flat washer/screw. Reconnected the electrical connection and that was that. All-in-all an easy repair.
Parts Used:
Condenser Fan Motor
  • Nicholas from Frankfort, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
45 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Excessive noise was coming from the freezer section of my side be side refrigerator
Cleaning out the freezer took the longest time. Once the freezer was clean I turned off the freezer which did not deactivate the light in the freezer. This is a tight area to work in and not having to hold a flashlight made the job much easier. I then removed the shelf slider brackets for the 3 lower pullout drawers. The next step was to remove the interior aluminum back panel (6 screws) which covers the evaporator motor and the coil. Before removing the 3 electric wires that are attached to the evaporator motor make sure the power is off to the motor. The removal of the motor was fairly straightforward and I would suggest removing the plastic fan blade first and then the connector wires. It helped knowing in advance that the plastic fan blade would come off with a little prying. Be careful when prying the fan off so that you don’t damage the plastic motor mount bracket. Once you have installed the motor I would suggest turning the freezer back on to make sure that the evaporator motor works before reinstalling the aluminum back panel and slider brackets.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Jon from Houston, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
43 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10648262891
1 - 15 of 434