fridge made a loud growling noise when running
removed the clip that the motor was attached too put the new motor back on reinstalled the clip back on the fridge plugged the wire harness in and works perfect now . it was easier to remove the clip than to try to install the motor by itself its just to tight and you cant get in there
Parts Used:
Condenser Fan Motor Kit
  • Bob from Mandan, ND
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Needed an extra refrigerator shelf
I slipped the shelf onto the brackets that already were on the sides of the refrigerator.
Parts Used:
Refrigerator Slide-Out Shelf with Glass
  • Daniel from HUDSON, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
22 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked Evaporation tray was leaking water on kitchen floor
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
Parts Used:
Evaporator Drip Tray
  • Jerrel from REDDING, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench (Adjustable)
20 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer intermitently warmed to around 31 degrees
Being a jet mechanic I had to familiarize myself with refrigerators, then after 2 or 4 hours of online studying, opened the door pulled the temp knobs of, removed the panel by gently prying the top of the panel out,then up and out with it. I found tapping on the thermostat shaft or wiring connection started the compressor, verifying my belief it was the thermostat. Don't mess with wiring if you don't know exactly what you are doing and unit is plugged in, you will electrocute yourself!!! I received the thermostat, UNPLUGGED THE UNIT from the house wall outlet, took one screw out of the upper inner wall at the very top to remove cover, one screw at the back top to remove the other cover (at the control vent) for access to remove sensor, then removed 4 screws , 2 front, 2 underneath to drop the housing for defrost timer, etc., and then took 2 screws from thermostat, unplugged wiring from thermostat (3 wires, be sure to put them back on the same place in the new thermostat). Remove old thermostat, slide plastic cover off sensor and slide back onto new thermostat sensor. Be careful not to kink the line or bend it to sharp you will damage it, (use gentle curves when bending it,) and re assemble everything in reverse order. This took about me 15 or 20 minutes start to finish. Plug into wall and watch thermometer to verify success.
Parts Used:
Thermostat Assembly
  • brett from garland, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unable to set the cold-control to a sufficiently cold setting.
Linkage on the cold-control mechanism in the air diffuser assembly was broken. It was necessary to access the diffuser assembly from both the refrigerator and freezer sides of the unit.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now.
Parts Used:
Air Diffuser Assembly
  • Leo from Lewisport, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
34 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not auto close
I removed the screws on the upper hinge and removed the door. I removed the lower cam in about 2 minutes and had it replaced. The upper cam was a tight fit in the door and I resorted to vise-grips to remove it. Total time to replace cams and put the door back on was 30 minutes. This saved me $100.
Thanks
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • James from Hampton, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
18 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The icemaker in the fridge stopped working
The repair was so simple. I removed the old icemaker in about 3 minutes and unpacked and installed the new one is about 10 minutes. It was literally a matter of removing a few screws! Eady to follow instructions!
Parts Used:
ICEMAKER
  • Rebecca from Dayton, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
17 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
Refrigerator Door Switch
  • bill from escondido, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It was not coming out of defrost cycle
First I installed a defrost timer, (the old timer had burnt out contacts in it) It seemed to work for a few days, then went back to not comng out of defrost cycle, I then installed a defrost thermostat. It seems to be working better than before. I found out that maybe I wasn't running it cold enough. So I turned it up colder. Now it works ok for 2 - 3 days, then I check the Temp in the freezer and its up to 6o. So I manually reset the timer and it works for 2 - 3 days. Don't know what to do now to fix it.
Parts Used:
Bi-Metal Defrost Thermostat
  • Dale from Flemingsburg, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
24 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The edges of the Meat pan slide were broken.
I removed the glides under the edges of the meat pan, remove the old pan, put the new pan in and replaced the glides. I was very pleased with PartSelect. I ordered my part, and it arrived the very next day. I will definitely order my next replacement part thru PartSelect.
Parts Used:
Refrigerator Crisper Drawer With Handle
  • Michael from Bakersfield, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compresser would not kick in, it would click on and off.
Unplugged the starter from compresser and put the new part in and all worked. Great service and I like the OEM parts not aftermarket. Will definately do service with you again. Thanks for making my life easier.
Parts Used:
Start Device Run Capacitor
  • terry from farmington, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
burned out Evaporator Fan Motor
simply removed wires from the old motor and gently lifted it out by by the metal clips - put the old bracket on the new motor, snapped on the new fan, replaced the wires, reinstalled the shield. All done in about 15 min.
Parts Used:
Evaporator Fan Motor - 120V 60Hz Evaporator Fan Blade
  • Robert from Surprise, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor was noisy
I removed 4 screws holding the motor mounting bracket and removed the assy from the unit. I then removed 3 screws holding the motor to the bracket. I put the fan blade on the new motor and reattached the motor to the bracket. I plugged in the wiring adapter to the motor and reinstalled the bracket in the unit with the 4 screws. Finally I attached the unit wiring connector to the motor.
It was relatively easy.
Parts Used:
Condenser Fan Motor Kit
  • Rick from Florence, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer wouldn't freeze and the refrigerator wouldn't refrigerate.
Same as everybody else on this post. Real easy. Actually, I just wish I would have done it sooner.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Leandro from Baldwin Park, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Parts Used:
Defrost Timer
  • David from Arnold, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10640212010
46 - 60 of 548