14 of 17 people found this instruction helpful
Parts Used
Level of DifficultyA Bit Difficult
Time to do repair:Less than 15 mins
ToolsPliers, Screw drivers
Customereric from inglewood TN
Faulty controller and possibly capacitor
After building a test box and determining the Controller was bad simply ordered parts and installed. Installation was a little difficult due to locking spades on electrical connections.
Unplug all power from freezer. Remove Bail wire from controller capacitor unit and remove from compressor by pulling STRAIGHT from compressor body to avoid bending contacts.
Use a very small instrumentation screwdriver to release locking spade on yellow and white wires. To unlock slide screwdriver in slot along wire entry to controller body while gently pulling on wire. Note position of wires and replace on new unit in same position/order. Plug new run capacitor into new controller being careful to orient capacitor to proper position (hole matches guide on controller unit). Plug newly installed controller and capacitor into condensor and replace bail wire.
Make sure timer is not in defrost mode - manually advance timer if necessary to ensure timer is in run mode. Turn temperature control to coldest setting. Plug in and hopefully enjoy the humming noise of your newly repaired and operational compressor and freezer.
|
5 of 7 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsScrew drivers
CustomerKenneth from Safford AZ
Freezer compressor quit running causing freezer to defrost and ruin all contents.
Very simple repair. Removed the bail that holds the compressor controller and run capacitor from the compressor, removed the controller & capacitor, inserted a very small screwdriver into the controller to compress the barbs that hold the electrical wires to the controller. Plugged in the wires to the new controller in the same position as the original, plugged in the capacitor and then plugged the entire unit back onto the compressor, replaced the wire bail, plugged in the freezer and repair was complete.
|
0 of 1 people found this instruction helpful
Parts Used
Level of DifficultyA Bit Difficult
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerJim from Cherryvale KS
Controller showed signs of the plastic housing had melted.
I paid attention to how the old part came off. You need a small (very small) flat bladed screwdriver to release the two wires that plug into the controller. I checked that it was a bit difficult but it would had been easier if I could have found a screwdriver sooner.
|