Vent with Seal

PartSelect Number PS344128

This part works with the following brands: Whirlpool, Admiral, Estate, Inglis, Kenmore, KitchenAid, Roper, Maytag, Crosley, Jenn-Air, Hardwick, Magic Chef, Amana, Caloric & Glenwood.

This part fixes the following symptoms:

  • Leaking water.
  • Compare At

    $43.72
  • You Save

    $7.29
  • Your Price

    $36.43
In Stock
Fast Shipping Get this part fast. Average delivery time via regular ground: 1.8 days.

Related Parts Additional or alternate parts to consider.

Part PhotoPart DescriptionPriceAvailability

Door Vent Screen

Part Number 343377

$4.46
In Stock

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 3.3 / 5.0, 2 reviews What's this?
1-2 of 2
 

7 of 11 people found this instruction helpful

Parts Used

Level of DifficultyA Bit Difficult

Time to do repair:30 - 60 mins

ToolsScrew drivers

CustomerLouis from Niceville FL

Water dripped out from the bottom of door.

Diagnosing the problem, i.e. finding the source of the leak, was the hardest part. The best clue was the leak only occurred well into the cycle when the water was hot and steam was coming out the vent. I then assumed there was a bad seal and steam & condensed water was leaking down into the door. I replaced the vent duct & seal, a broken drip cover (an internal part in the door), and replaced a missing rinse aid cap. This stopped the leak.

Help other customers find the most helpful instructions.

Were these instructions helpful?

5 of 5 people found this instruction helpful

Parts Used

  • Vent with Seal

Level of DifficultyEasy

Time to do repair:15 - 30 mins

ToolsScrew drivers

CustomerEdward from Sebastopol CA

Steam venting past gasket causing short in switch at handle lock.

Removed inner cover of door. Pried Vent Assembly from door, peeled off thin sponge gasket strip from inner door, installed new thin sponge gasket strip on inner door vent opening bottom, snapped Vent Assembly into inner door opening, reinstalled inner door cover to door.
Recommend removing Vent screen from inner door first to expose locking tabs of Vent Assembly to ease removal and installation of Vent Assembly. I assume vent cover will come off if pried with small screw driver. I didn't remove vent cover and had difficulty removing and installing Vent Assembly. (I did accomplish it though)

Help other customers find the most helpful instructions.

Were these instructions helpful?

1-2 of 2