158 of 168 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:30 - 60 mins
ToolsNutdriver, Pliers, Screw drivers
CustomerMichael from Kirkwood MO
Gas dryer would not ignite
1. Removed lint screen and holder frame. Unplugged the electrical cord and closed the gas valve in the line before it goes into the dryer. 2. Removed two bolts at bottom front of machine and took off the bottom front panel. 3. Removed three bolts from black plastic exit vent and took it out to give more room to access everything. 4. removed two wires and screws on the limit thermostat. Did the reverse to place the new one. 5. Removed wires (remembering placement), then holder screw. rotated the Gas Dryer Sensor counter clockwise to release the bottom tab so the sensor can be taken off the flame tube. Did the reverse to place the new one on. 6. Removed the one screw on the gas/flame tube that holds the bracket and igniter inside the flame tube. Removed the wires fro the igniter (remember placement) Slid the whole assembly toward the back of the machine to get the tube off the gas valve then rotated the whole assembly counter-clocwise to release the tab on the left side of the bracket. This was a little tight and had to work with it a bit to get the tab out and slide the whole piece out of the flame tube. 7. Once the tube and igniter were out i removed the scree that holds the igniter and replaced with the new one. Made sure no dust, etc. was in the piece. 8. Did the reverse to place the tube/igniter back into the flame tube. 9. Carefully and forcefully removed the wire connectors to the two coils. These were tough to get off. Removed the two screws that hold the bracket that holds the two coils in place. Slid the coils off the spindles remembering which one has the two wire connection and which one has the three wire connection and the way they went on. Replaced the old with the new. Placed the bracket onto the new coils and made sure the little bumps on the top are in the holes in the bracket. Tightened the screws to hold the coil bracket. Reattached the wire connectors to the coils making sure they go ALL the way back on. 10. Vaccumed everything I could to get lint, dust, etc. out. 11.Replaced the black vent plastic. 12 Made sure the exit vent on the back was not crimped or clogged. Checked the little flap door where the vent goes outside to make sure it opens and closes super easy to no air flow is restricted. 13. For testing I left the bottom panel open. Make sure you closed the door, reconnect the plug and turn the gas valve back on. Hit the go button on autodry or timed dry. The door must be closed to create the closed circulation of the system so the fan sucks the flame into the tube otherwise the flame will not fire deep into the tube and will set off one fo the overheat sensors. After hitting the go button your drum will start to rotate, then a few seconds later you'll hear a click and your igniter will start to burn bright orange. Another click and the gas should flow and ignite. 14. This shows that you've fixed the ignition problem. I just replaced everything I thought that could be wrong in stead of hunting and trial and error. All the parts were about $137 so I thought it was worth making sure. 15. IMPORTANT: If during your test the flame turns off after a little while then turns back on only to turn off again, don't panic. This happened to me as well. I found that you need to run the dryer with wet clothes in the dryer. The wetness in the clothes will keep the autodry sensor from shutting off the dryer since there will be moisture in the exhaust. If it's on timed dry the wet clothes will cool the exhaust air and keep the overheat sensors from turning the heat off. So no heating of dry clothes to get out wrinkles. Just dry the wet clothes. This is all I did and it's been working great so far. Good Luck!
|
125 of 141 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:30 - 60 mins
ToolsNutdriver, Screw drivers, Socket set
CustomerGary from Haverhill NH
Dryer ran but would not heat
PartSelect showed seven different possibilities why the dryer wouldn't heat. I removed the two screws to remove the bottom panel and turned the dryer on and noticed that the heating element that ignites the gas was working fine. This meant that it was not getting gas so it could be the gas valve or one of the two gas valve coils which are located on top of the gas valve. I borrowed my neighbor"s ohm meter and touched the two probes on the coils terminals to check for continuity and found that one of the coils read zero. I then took both of the coils out by removing two screws and tested each coil again. One coil read 500-850 and the other read zero. This meant that it was no good so I called for the part and received it in three days. I reassembled the parts and turned the dryer on and it fired up after a few seconds. It works as good as new. The part plus shipping was less than $30. My repairman would have charged me $150-$200. While the dryer was apart I gave it a good cleaning with a vacuum and a toothbrush in delicate areas. I also removed and cleaned the lint trap housing by removing two nuts. I didn't know much about gas dryers, but thanks to PartSelect I easily fixed it myself.
|
56 of 66 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
- 'M' Series New Style Coil Kit
Level of DifficultyA Bit Difficult
Time to do repair:15 - 30 mins
ToolsNutdriver
CustomerJoaquin from Las Vegas NV
Timer wasn't working (new timer)
Timer wasn't working on the regular cycle so I replace it with a new one from partselect. It still wasn't working so I ordered and replace the cycling thermostat, the thermal fuse I also cleaned the vent and dryer it still didn't work so I read the diagram for the electrical and found that a coil for the gas valve is line with timer. I ordered the coils for the valves, replaced both valves and tested the dryer and it work just like when I first bought the appliance.
|
38 of 42 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsNutdriver, Screw drivers
CustomerRobert from Seattle WA
Dryer would only heat cycle once
I removed the two screws holding the front panel to expose the lower works and verified the heating cycle failure. After a check of the vent system, checking the sensors for continuity and coils for resistance, I retired to the 'net for support. Accepting the general consensus that the most frequent, common and likely failure to be the coils, I rechecked them with the meter and found the two pronged coil to have significantly more resistance than the three prong coil. That was enough evidence to point to the coils. While I waited for the part to arrive, I replace the vent ducting. When the parts arrived I removed the two Phillips screws holding the coils, removed the old ones, installed the new ones, replaced the bracket, put the front cover back on and in less then ten minutes clothes where drying.
|
31 of 34 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyA Bit Difficult
Time to do repair:Less than 15 mins
ToolsScrew drivers
CustomerJames from Limington ME
The dryer heated up for a few minutes and then cooled down.
1 Unplug power. 2. Remove the front of the unit by removing the two screws at the bottom of the front panel. Front dryer panel will swing out from the bottom and then the clips will release the top of the panel, careful not to disconnect the dryer door switch. ( can be unplugged to remove the front panel out of the way.) 3. Looking inside the unit on the right side you will see the gas value. On top of the gas unit you will see two small coils the coil closest to the burner has two leads on it. Remove the two screws to get to the coils, remove the medal plate, remove the connector then lift off the secondary coil. Replace and test. You can test unit with the front panel off. (be careful). If no heat, check that the Flat Style igniter is glowing. (ohm out both coils) before ordering parts. Intermittent heat problems. I replaced the secondary coil, it did ohm out o:k but it had swollen and was very tight on the shaft.
|
22 of 22 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:30 - 60 mins
ToolsScrew drivers
Customerandy from Bethesda MD
Dryer flame goes out after about 8-minutes from start and won’t work again until a 15-minute rest.
There was no problem with lint build-up within the dryer & the exhaust vent. I removed the gas cycling thermostat & thermal fuse from system & dryer still was not operating correctly. The radiant sensor & hi-limit thermostat both seemed to be operating correctly. That left either of the two coils as the culprits. I replaced both coils & the problem was corrected.
|
19 of 20 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers, Wrench(Adjustable)
CustomerDavid from Bedford IN
Dryer would start and heat, but after 1st cycle the burner would not fire and a buzzing sound was coming from the gas valve solenoid area. Igniter and other functions worked fine.
Removed front of dryer, unplugged each coil to determine where buzzing was coming from.....determined it was the boosting coil....ordered part and replaced. Dryer works great....we think it had be going bad over time because drying times have noticeable decreased.
|
17 of 17 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyA Bit Difficult
Time to do repair:30 - 60 mins
ToolsNutdriver, Screw drivers, Socket set
CustomerMonique from Mission Viejo CA
My dryer only heats up at the beginning of cycle so my clothes will not dry.
I remove the front control panel and to get to the bottom front dryer door off. Using my volt meter i checked all the sensors and thermal. I surf the internet for hint and some one mention to replace the coil since some time you could have one goes out and the other working still. After i replaced the coil kit it works like a champ.
|
15 of 16 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerChris from Laguna Niguel CA
Would not heat sometimes
Pulled the big front panel by removing two screws near bottom of front and pulling out at bottom until the top pops loose. Vacuumed out all of the dust and checked for loose connections. Ran dryer - igniter would light, but no gas. Checked the two solenoids with a VOM. the one with the two leads would intermittently read Infinity (open). Super simple repair. Remove two screws on solenoid bracket on top of the gas valve, Replace solenoid and plug it back in with the easy push-on connector. NO PROBLEM - all fixed.
|
14 of 16 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerSharon from Houston TX
Dryer would get hot for a while, then quit heating
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
|
13 of 14 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsScrew drivers, Wrench set
CustomerJack from Conroe TX
Gas burner would not ignite
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)
Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.
|
12 of 12 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerMatthew from Lake Worth FL
Extended drying time. Some but not enough heat. Burner would light for 15-18 seconds at first then shut off for 1-3 minutes then light for 3-6 seconds and repeat for the length of the cycle.
Determining the problem was the hardest part. With multiple parts (coils,thermostats...)possibly causing similar symptoms, I narrowed it down to the two coil valves. Un plug the dryer. Remove two screws at the base of the front panel. Turn the front panel 180 degrees to avoid disconnecting the door switch. Gas valve with coils on top are on the right in front. Remove two screws in bracket holding coils, disconnect the wires, replace with new coils and reconnect wires. One coil has 2 terminals the other has 3 no chance of crossing the wires. I used an offset/right angle screw driver for one of the bracket screws due to close proximity to the drum. A stubby phillips head will work. You can check the burner operation with the front panel off as long as the door switch is still attached. Swing the front panel around and lift back into place securing with the two screws. Dryer works fine now.
|
13 of 16 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyEasy
Time to do repair:30 - 60 mins
ToolsNutdriver, Screw drivers
CustomerSteven from Sauk Village IL
Intermittent or no gas ignition, hsi ignightor working
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
|
13 of 17 people found this instruction helpful
Parts Used
-
- 'M' Series New Style Coil Kit
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsPliers, Screw drivers
CustomerPHILIP from LONG ISLAND CITY NY
Time clock not moving .Not enough heat
Opened front panel .Tested both coils on gas valve. Found no continuity on one of the coils. Replaced coil, dryer works like new.
|
12 of 15 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:Less than 15 mins
ToolsScrew drivers, Socket set
CustomerRichard from Jerome MI
Dryer would dry for 5-10 minuets then no heat
I tested the dryer coils and found that they were getting a voltage but would not open the gas valve. Coils were not bad but weak. After they warmed up they would not open the gas valve. It took 10 min to repace both coils and the heat sensor.
|