This gas dryer ignition coil set comes with two ignition coils: one three terminal Boost/Hold coil, and one two terminal secondary coil. Usually only one of them burns out but you should replace them as a set. Both have to be operational for the gas valve to open.

This part works with the following brands: Whirlpool, Admiral, Estate, Inglis, Kenmore, KitchenAid, Roper, Maytag, Crosley, Jenn-Air, Hardwick, Magic Chef, Amana, Caloric & Glenwood.

This part fixes the following symptoms:

  • No heat or not enough heat.
  • Takes too long to dry.
  • Shuts off too soon.
  • Timer will not advance.
  • Will Not Start.
  • Noisy.
  • Will not shut off.
  • Compare At

    $18.12
  • You Save

    $3.02
  • Your Price

    $15.10
In Stock
Fast Shipping Get this part fast. Average delivery time via regular ground: 1.8 days.

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 3.9 / 5.0, 87 reviews What's this?
1-5 of 87
 

554 of 662 people found this instruction helpful

Parts Used

Level of DifficultyEasy

Time to do repair:30 - 60 mins

ToolsNutdriver, Pliers, Screw drivers

CustomerMichael from Kirkwood, MO

Gas dryer would not ignite

1. Removed lint screen and holder frame. Unplugged the electrical cord and closed the gas valve in the line before it goes into the dryer.
2. Removed two bolts at bottom front of machine and took off the bottom front panel.
3. Removed three bolts from black plastic exit vent and took it out to give more room to access everything.
4. removed two wires and screws on the limit thermostat. Did the reverse to place the new one.
5. Removed wires (remembering placement), then holder screw. rotated the Gas Dryer Sensor counter clockwise to release the bottom tab so the sensor can be taken off the flame tube. Did the reverse to place the new one on.
6. Removed the one screw on the gas/flame tube that holds the bracket and igniter inside the flame tube. Removed the wires fro the igniter (remember placement) Slid the whole assembly toward the back of the machine to get the tube off the gas valve then rotated the whole assembly counter-clocwise to release the tab on the left side of the bracket. This was a little tight and had to work with it a bit to get the tab out and slide the whole piece out of the flame tube.
7. Once the tube and igniter were out i removed the scree that holds the igniter and replaced with the new one. Made sure no dust, etc. was in the piece.
8. Did the reverse to place the tube/igniter back into the flame tube.
9. Carefully and forcefully removed the wire connectors to the two coils. These were tough to get off. Removed the two screws that hold the bracket that holds the two coils in place. Slid the coils off the spindles remembering which one has the two wire connection and which one has the three wire connection and the way they went on. Replaced the old with the new. Placed the bracket onto the new coils and made sure the little bumps on the top are in the holes in the bracket. Tightened the screws to hold the coil bracket. Reattached the wire connectors to the coils making sure they go ALL the way back on.
10. Vaccumed everything I could to get lint, dust, etc. out.
11.Replaced the black vent plastic.
12 Made sure the exit vent on the back was not crimped or clogged. Checked the little flap door where the vent goes outside to make sure it opens and closes super easy to no air flow is restricted.
13. For testing I left the bottom panel open. Make sure you closed the door, reconnect the plug and turn the gas valve back on. Hit the go button on autodry or timed dry. The door must be closed to create the closed circulation of the system so the fan sucks the flame into the tube otherwise the flame will not fire deep into the tube and will set off one fo the overheat sensors. After hitting the go button your drum will start to rotate, then a few seconds later you'll hear a click and your igniter will start to burn bright orange. Another click and the gas should flow and ignite.
14. This shows that you've fixed the ignition problem. I just replaced everything I thought that could be wrong in stead of hunting and trial and error. All the parts were about $137 so I thought it was worth making sure.
15. IMPORTANT: If during your test the flame turns off after a little while then turns back on only to turn off again, don't panic. This happened to me as well. I found that you need to run the dryer with wet clothes in the dryer. The wetness in the clothes will keep the autodry sensor from shutting off the dryer since there will be moisture in the exhaust. If it's on timed dry the wet clothes will cool the exhaust air and keep the overheat sensors from turning the heat off. So no heating of dry clothes to get out wrinkles. Just dry the wet clothes. This is all I did and it's been working great so far. Good Luck!

Help other customers find the most helpful instructions.

Were these instructions helpful?

258 of 293 people found this instruction helpful

Parts Used

  • 'M' Series New Style Coil Kit

Level of DifficultyEasy

Time to do repair:30 - 60 mins

ToolsNutdriver, Screw drivers, Socket set

CustomerGary from Haverhill, NH

Dryer ran but would not heat

PartSelect showed seven different possibilities why the dryer wouldn't heat. I removed the two screws to remove the bottom panel and turned the dryer on and noticed that the heating element that ignites the gas was working fine. This meant that it was not getting gas so it could be the gas valve or one of the two gas valve coils which are located on top of the gas valve. I borrowed my neighbor"s ohm meter and touched the two probes on the coils terminals to check for continuity and found that one of the coils read zero. I then took both of the coils out by removing two screws and tested each coil again. One coil read 500-850 and the other read zero. This meant that it was no good so I called for the part and received it in three days. I reassembled the parts and turned the dryer on and it fired up after a few seconds. It works as good as new. The part plus shipping was less than $30. My repairman would have charged me $150-$200. While the dryer was apart I gave it a good cleaning with a vacuum and a toothbrush in delicate areas. I also removed and cleaned the lint trap housing by removing two nuts. I didn't know much about gas dryers, but thanks to PartSelect I easily fixed it myself.

Help other customers find the most helpful instructions.

Were these instructions helpful?

114 of 130 people found this instruction helpful

Parts Used

  • 'M' Series New Style Coil Kit
  • 'M' Series New Style Coil Kit

Level of DifficultyA Bit Difficult

Time to do repair:15 - 30 mins

ToolsNutdriver

CustomerJoaquin from Las Vegas, NV

Timer wasn't working (new timer)

Timer wasn't working on the regular cycle so I replace it with a new one from partselect. It still wasn't working so I ordered and replace the cycling thermostat, the thermal fuse I also cleaned the vent and dryer it still didn't work so I read the diagram for the electrical and found that a coil for the gas valve is line with timer. I ordered the coils for the valves, replaced both valves and tested the dryer and it work just like when I first bought the appliance.

Help other customers find the most helpful instructions.

Were these instructions helpful?

88 of 94 people found this instruction helpful

Parts Used

  • 'M' Series New Style Coil Kit
  • 'M' Series New Style Coil Kit

Level of DifficultyEasy

Time to do repair:30 - 60 mins

ToolsScrew drivers

Customerandy from Bethesda, MD

Dryer flame goes out after about 8-minutes from start and won’t work again until a 15-minute rest.

There was no problem with lint build-up within the dryer & the exhaust vent. I removed the gas cycling thermostat & thermal fuse from system & dryer still was not operating correctly. The radiant sensor & hi-limit thermostat both seemed to be operating correctly. That left either of the two coils as the culprits. I replaced both coils & the problem was corrected.

Help other customers find the most helpful instructions.

Were these instructions helpful?

66 of 73 people found this instruction helpful

Parts Used

  • 'M' Series New Style Coil Kit

Level of DifficultyReally Easy

Time to do repair:Less than 15 mins

ToolsNutdriver, Screw drivers

CustomerRobert from Seattle, WA

Dryer would only heat cycle once

I removed the two screws holding the front panel to expose the lower works and verified the heating cycle failure. After a check of the vent system, checking the sensors for continuity and coils for resistance, I retired to the 'net for support. Accepting the general consensus that the most frequent, common and likely failure to be the coils, I rechecked them with the meter and found the two pronged coil to have significantly more resistance than the three prong coil. That was enough evidence to point to the coils. While I waited for the part to arrive, I replace the vent ducting. When the parts arrived I removed the two Phillips screws holding the coils, removed the old ones, installed the new ones, replaced the bracket, put the front cover back on and in less then ten minutes clothes where drying.