Single Solenoid Water Inlet Valve

PartSelect Number PS304349

The water inlet valve is a solenoid-operated switch that, when activated, releases water from the supply line to the water valve and into the compact icemaker mold. Use this part in conjunction with the dual inlet water valve for your appliance.

This part works with the following brands: GE, Hotpoint & Kenmore.

This part fixes the following symptoms:

  • Leaking water.
  • Compare At

    $77.40
  • You Save

    $12.90
  • Your Price

    $64.50
In Stock
Fast Shipping Get this part fast. Average delivery time via regular ground: 1.8 days.

Related Parts Additional or alternate parts to consider.

Part PhotoPart DescriptionPriceAvailability

Dual Inlet Water Valve

Part Number 304348

$65.55
In Stock

RELAY & HARNESS ASSY

Part Number 296026

$98.45
Special Order

Water Valve Conversion Kit

Part Number 303179

This kit comes with the primary and secondary valves, tubing, connectors and brackets. ***NOTE: The wheels shown in the pictures are NOT included with this kit.

$130.53
In Stock

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 3.4 / 5.0, 4 reviews What's this?
1-4 of 4
 

3 of 5 people found this instruction helpful

Parts Used

  • Single Solenoid Water Inlet Valve

Level of DifficultyReally easy

Time to do repair:30 - 60 mins

ToolsNutdriver, Wrench(Adjustable)

CustomerScott from Palm Harbor FL

Water was leaking from under fridge - right side back when facing the fridge from the front

Very simple repair:
A. Turned off power and disconnected main copper water line into fridge.
1. Removed rear "dust cover".
2. Removed screw (with nut head) that holds water valve assembly on.
3. Removed water valve assy from fridge by lifting up - note that tab has to come out of hole in fridge.
4. Unhooked water lines and electrical connector from valve.
5. Removed 2 screws holding water valve to water valve assembly.
6. Replaced cracked water valve with new water valve.
7. Reversed process and assembled back together.
8. 30 - 40 minutes estimated time.

Help other customers find the most helpful instructions.

Were these instructions helpful?

1 of 3 people found this instruction helpful

Parts Used

Level of DifficultyA Bit Difficult

Time to do repair:30 - 60 mins

ToolsNutdriver, Pliers, Wrench set

CustomerJames from Nashville TN

Leak on bottom of refrigerator.

removed back cover covering compressor and condenseing fan ,located vavle system,there are two the one leaking was the single solenoid vavle .To remove ,remove screws holding the double solenoid cause the single one is mounted to the double one ,once that done undo the water lines under the double vavle and pull out vavles .The bracket holding the single is connected to the double one by two screws,then undo the water lines ,then the wire connecter,then the reverse of what you do with the new one.

Help other customers find the most helpful instructions.

Were these instructions helpful?

1 of 6 people found this instruction helpful

Parts Used

Level of DifficultyEasy

Time to do repair:30 - 60 mins

ToolsScrew drivers, Wrench set, Wrench(Adjustable)

CustomerGary from Shreveport LA

Ice maker solenoid valve leaking through

Replaced all solenoid valves. Problem solved. Replaced all to prevent future problems with others.

Help other customers find the most helpful instructions.

Were these instructions helpful?

0 of 4 people found this instruction helpful

Parts Used

  • Single Solenoid Water Inlet Valve

Level of DifficultyEasy

Time to do repair:15 - 30 mins

ToolsNutdriver, Screw drivers, Wrench(Adjustable)

Customerladdie from benton KY

Cracked valve body

swapped new valve for cracked valve, after marking water lines to which side of the old valve they were on.