268153-1-S-GE-WE4X692           -'M' Series Primary Dual Coil Gas Valve
268153-1-S-GE-WE4X692           -'M' Series Primary Dual Coil Gas Valve 268153-2-S-GE-WE4X692           -'M' Series Primary Dual Coil Gas Valve

'M' Series Primary Dual Coil Gas Valve

PartSelect Number PS268153

This 'M' series coil is both a boosting as well as a holding coil. It has three terminals.

This part works with the following brands: GE, Hotpoint & Kenmore.

This part fixes the following symptoms:

  • No heat or not enough heat.
  • Compare At

    $33.06
  • You Save

    $5.51
  • Your Price

    $27.55
In Stock
Fast Shipping Get this part fast. Average delivery time via regular ground: 1.8 days.

Related Parts Additional or alternate parts to consider.

Part PhotoPart DescriptionPriceAvailability

'M' Series Secondary Coil - 2 Terminals

Part Number 268154

$23.27
In Stock

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 3.5 / 5.0, 2 reviews What's this?
1-2 of 2
 

38 of 46 people found this instruction helpful

Parts Used

Level of DifficultyEasy

Time to do repair:30 - 60 mins

ToolsNutdriver, Screw drivers

CustomerErik from Newport ME

Dryer would heat initially, but would not heat throughout entire cycle.

-Removed top panel
-Removed right side panel
-Gas coils were held in together under a metal strap
-Removed 2 screws holding strap
-Unplugged 1 wire harness to each coil
-Removed Primary and Holding coil
-Replace with two new coils, replace strap and plug in each harness
-Replace side, then top panel
-Under 1 hour job...Took 45 minutes to remove/replace panels and only 5 minutes to replace coils.
-Anyone with a little mechanical ability can save $150 in labor and spend just $50 in parts to fix this problem.
-Questions: Erik at elstransport13@gmail.com

Help other customers find the most helpful instructions.

Were these instructions helpful?

28 of 34 people found this instruction helpful

Parts Used

Level of DifficultyReally easy

Time to do repair:30 - 60 mins

ToolsScrew drivers, Socket set

CustomerVinny from Port Chester NY

Dryer would not get hot after igniter went on, no gas being let in.

Removed top cover of dryer with screwdiver 2 screws, removed front cover 2 small bolts with 5/16 scoket. Removed coil brackets with shor screwdriver replace coils as ness. and put covers back on and works great!

Vinny