11 of 14 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerEugene from Standish ME
Would blow the internal 15amp fuse when pressing the start button
Used the trouble shooting guide and wire diagram found inside the microwave (thanks GE). Found the HV capacitor and diode had shorted. Replaced the capacitor and diode........works like new.
|