2341874-2-S-Whirlpool-W10189703-Evaporator Fan Motor - 60Hz 120V
2341874-2-S-Whirlpool-W10189703-Evaporator Fan Motor - 60Hz 120V 2341874-1-S-Whirlpool-W10189703-Evaporator Fan Motor - 60Hz 120V 2341874-3-S-Whirlpool-W10189703-Evaporator Fan Motor - 60Hz 120V

Evaporator Fan Motor - 60Hz 120V

PartSelect Number PS2341874

This evaporator fan motor is located in the back of the freezer, and circulates air over the refrigerator coils. These coils will convert the heat into cool air, which is then circulated. NOTE: This motor uses 2 brackets which are sold separately.

This part works with the following brands: Whirlpool, Admiral, Estate, Inglis, Kenmore, KitchenAid, Roper, Maytag, Crosley, Jenn-Air, Hardwick, Magic Chef, Amana, Caloric & Glenwood.

This part fixes the following symptoms:

  • Fridge too warm.
  • Noisy.
  • Freezer section too warm.
  • Will Not Start.
  • Freezer not defrosting.
  • Compare At

    $55.64
  • You Save

    $9.27
  • Your Price

    $46.37
In Stock
Fast Shipping Get this part fast. Average delivery time via regular ground: 1.8 days.

Videos For installing this part.

Related Parts Additional or alternate parts to consider.

Part PhotoPart DescriptionPriceAvailability

Fan Support Bracket

Part Number 2329902

$23.62
In Stock

BRACKET

Part Number 329763

$19.55
In Stock

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 4.0 / 5.0, 5 reviews What's this?
1-5 of 5
 

65 of 74 people found this instruction helpful

Parts Used

  • Evaporator Fan Motor - 60Hz 120V

Level of DifficultyEasy

Time to do repair:30 - 60 mins

ToolsNutdriver, Screw drivers

CustomerBrian from Smock PA

Fridge was warm. No air circulating at all. Food was spoiling fridge was just over 1 year old

First I removed the two screws that secure the guard in bottom back of the freezer and removed it . Next I removed the two screws that secure the guard on the back wall of the freezer and removed it. There are three wires connected to the motor, I unplugged those and removed the two screws that secure the motor and removed it. I swapped the grommets, blade and support bracket from the old motor. I put it back together in reverse steps and its working great. My mother-in-law can,t stop thanking me ! I saved her at least $400 to buy a new fridge. Thank You, Brian Miner

Help other customers find the most helpful instructions.

Were these instructions helpful?

18 of 22 people found this instruction helpful

Parts Used

  • Evaporator Fan Motor - 60Hz 120V

Level of DifficultyEasy

Time to do repair:Less than 15 mins

ToolsNutdriver

CustomerMax from Waco TX

Evaporator motor burned out

Very pleased with the delivery time. Was able to repair the refrigerator before the beer got hot. Replacement was easy.
Removed blower housing. Replaced motor. Put blower housing back in place.

Help other customers find the most helpful instructions.

Were these instructions helpful?

8 of 10 people found this instruction helpful

Parts Used

  • Evaporator Fan Motor - 60Hz 120V

Level of DifficultyEasy

Time to do repair:15 - 30 mins

ToolsNutdriver, Screw drivers

CustomerJames from Aubrey TX

Motor slowing down and speeding up off and on

Unplugged the machine removed the bottom plate and back plate and ice maker.Removed 2 wires to motor and ground wire.Removed 2 mounting nuts for motor,installed new motor and used old fan blade for new motor .Reinstalled in reverse order plugged in and tested fine.

Help other customers find the most helpful instructions.

Were these instructions helpful?

7 of 9 people found this instruction helpful

Parts Used

  • Evaporator Fan Motor - 60Hz 120V

Level of DifficultyReally easy

Time to do repair:15 - 30 mins

ToolsNutdriver

CustomerJohn from Blairsville GA

Freezer not coolling properly. Lower temp. 2 degrees upper temp. 60 degrees.

Take bottom racks and baskets out of freezer. Remove back sheet metal panel, 8 screws. Remove motor and bracket, 2 screws. Umplug wires on motor. Remove two more screws to take mounting bracket off motor. Install in reverse order. Simple job. Maybe 20 minutes. Besure to shut freezer off before startin work.

Help other customers find the most helpful instructions.

Were these instructions helpful?

7 of 9 people found this instruction helpful

Parts Used

  • Evaporator Fan Motor - 60Hz 120V

Level of DifficultyReally easy

Time to do repair:15 - 30 mins

ToolsPliers, Screw drivers

CustomerYvonne from modesto CA

Evaporator motor burned out

Unplugged the machine removed the bottom plate and back plate and ice maker.Removed 2 wires to motor and ground wire.Removed 2 mounting nuts for motor,installed new motor and used old fan blade for new motor .Reinstalled in reverse order plugged in and tested fine.

Help other customers find the most helpful instructions.

Were these instructions helpful?