121 of 131 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerBill from Cleveland Heights OH
Flap to ice dispenser would not close
The flap to the ice dispenser would not close, which allowed the ice dispenser to frost up, freezing the water dispenser.
This was a simple fix. The solenoid had stopped working, so it would not automatically close the door flap. I read some posts on this site that suggest that you had to remove the trim around the entire dispenser to get at the solenoid. My fridge may be a newer model, but in any event it was much easier than that. Just below the touch pad for choosing water, ice, or crushed ice (above where the ice/water dispenses) there are three very small holes spaced about an inch a part. After unplugging the fridge, I stuck a small philips-head screw driver in each, freeing spring clips. That allowed the touch pad to come off. I then removed four screws to remove a plastic piece covering the chute, giving me access to the flap and solenoid. I just unplugged the solenoid from the circuit board on the back of the touch pad and then removed three screws to remove the old solenoid. I replaced it with the new solenoid and plugged it into the circuit board. The touch pad then snapped back into place.
The hardest part was figuring out how to get at the solenoid. After I found that pushing the clips in those three holes allowed me to remove the touch pad, it could not be any easier.
|
31 of 34 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:30 - 60 mins
ToolsScrew drivers, Wrench set
CustomerJoe from Maryville TN
Flapper door stuck open allowing ice tube to frost shut
I read in a previous post how to do the job from outside fridge which saved me lots of time. No need to remove inner door lining. Here is my procedure: 1.Turned off power. 2.Snapped off outside trim ring. 3.Located three small holes inside lip just above ice tube. The center hole was not used. 4.Pushed rather firmly up through two remaining holes with small Allen wrench to release front control panel. 5.Removed (3) wire connectors from printed circuit board. Firmly pull/pry them straight out as lifting on retaining clip will break it off. I broke one & had to elect. tape it back in place later although I doubt it would have ever come off. 6.Release secondary panel by removing (4) screws. The problem was obvious as the solenoid had broken the crank arm off the flapper rod & trapped it open 7.Replaced solenoid, crank arm with flapper attached, spring & micro switch. Switch was okay but I changed anyway. 8.Cleaned all areas with 1/10 bleach water to sanitize. 9.Re-installed evrything in reverse order & all is okay. Thanks to someone for telling about those two small holes. Made job easy versus a very hard one.
|
25 of 33 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsScrew drivers
Customercarl from vacaville CA
Ice and water would not dispense at door
first I snapped out control face plate on outside of door. removed the screws for each part,and unplugged the wires at the connectors, replaced new parts and plugged in connectors to new circuit board.I decided to replace the board,switch and solenoid all at the same time, not knowing which part was bad.I have to say it was well worth it! it works better than when it was new!!!! It was a lot easier than I thought it was going to be.
|
14 of 18 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:30 - 60 mins
ToolsScrew drivers
CustomerJames from Malabar FL
Ice chute flapper not closing causing water dripping to floor and ice chute freezing up solid
I followed the video instructions for replacing the Flapper Valve and solenoid that Part Select suggested. It was one of the best DIY Reapair Sites I've used. Thank you
|
15 of 24 people found this instruction helpful
Parts Used
Level of DifficultyA Bit Difficult
Time to do repair:1- 2 hours
ToolsNutdriver, Screw drivers
CustomerERIC from MADISON AL
Ice door would not open far enough, ice would get stuck in chute
First remove about 30 screws w/nutdriver that are hidden under door seal then inside of freezer door will come off. Second remove about 10 screws that hold dispenser assy to the inside of door, then support the unit with tape so you don't damage the wires that connect it. Third, pop touchpad loose, then remove three sets of wires plugged into the circuit board. Fourth, remove four screws that hold the ice chute and light assy. Fifth, now remove the 3 screws that hold solenoid. These three screws that hold the solenoid will be very rusty, you may want to replace these also. I went ahead and replaced all the related parts because they are so hard to get to. Also took the opportunity to clean in here with bleach to remove all the black mold and rust. NOTE: when reassembling the inside of the freezer door to the outside of the door you must loosely attach the door on both sides in the middle first, then the top and bottom. Add some more screws on each side and tighten them all. Now you must check to be sure that the door is not racked. If the door is not sealed at the top or bottom, loosen the screws and twist the door a little and tighten screws and check door again for proper seal. Spent more time adjusting door to seal right than doing the actual repair.
|
11 of 14 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerWallace from Oxford ME
Ice dispenser door sticking open.
Unplugged power cord. Used a small screw driver to release the bottom of the control panel. Pulled it out and unplugged wires, then set it aside. Removed 4 screws from the housing shield and pulled it out. Now the solenoid assembly and related parts are accessable. I removed the solenoid assembly by loosening the top screw and removing the 2 bottom screws. This was the main problem, but I also replaced related parts that were worn or corroded. I also cleaned and disinfected everything in there while I had it apart because it was pretty nasty! Now it works like new.
|
9 of 9 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsNutdriver, Pliers, Screw drivers
CustomerMichael from Otsego MN
Water & ice disspenser quite working
first replace the solenoid behind the front display. than replace the mother board on the back side of the fridge due to a relay being burned out on it.
GE Wanted $300 + to come out and do the repair.
With partsselect and a little time I cut that cost in half.
Thank you,
Mike
|
9 of 11 people found this instruction helpful
Parts Used
Level of DifficultyA Bit Difficult
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerWilliam M from Ft Myers FL
Solenoid had become rusted/crank door wouldn't close
First, had to use punch tool to pop out electronic face panel. Face unit still connnect via wires. Use painters tape to hold against refrig. Next, Remove ice/water dispenser and also tape to door. This will give you access to solenoid. Remove the 3 screws holding it in place and unplug fsolenoid from Face Panel. Screw new solenoid and place and connnect to Panel. Goood idea is to unplug regrig. while doing this and put a little WD-30 on shaft of solenoid. May want to order new screws, could be rusty, that hold solenoid in place. Sounds a bit complicated but not that bad a job. You'll save over$100 over GE's service.
|
8 of 9 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsScrew drivers
CustomerMark from Skokie IL
Icemaker switch on door would not trigger motor
Replacing servo was not hard, but did not solve problem. Searched some more and the cure is to remove the light bulb from the dispenser. Seems that old bulbs draw too much current and cause the control panel to fail in sending signal to icemaker motor. Removing the bulb cured this fault and the control panel worked fine.
|
8 of 10 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerTurcotte's Housing Service, In from Newmarket NH
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
|
6 of 7 people found this instruction helpful
Parts Used
-
- Dispenser Door Solenoid Assembly
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerGraeme from Sarasota FL
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
|
5 of 5 people found this instruction helpful
Parts Used
-
- Dispenser Door Solenoid Assembly
Level of DifficultyReally easy
Time to do repair:Less than 15 mins
ToolsNutdriver, Screw drivers
Customerscott from lake orion MI
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
|
5 of 6 people found this instruction helpful
Parts Used
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerVictor from Houston TX
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.
I recomend these parts be replaced once time for each two years.
|
5 of 6 people found this instruction helpful
Parts Used
-
- Dispenser Door Solenoid Assembly
Level of DifficultyReally easy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerM Alan from Lebanon TN
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me. I then removed the 4 screws from the internal plate and pulled the plate toward me. Then I romoved the 3 screws holding the old solenoid and unplugged it. Next I put the new solenoid in place and replaced the three screws. Finally I plugged in the solenoid and replaced the internal and external plates.
|
5 of 7 people found this instruction helpful
Parts Used
Level of DifficultyEasy
Time to do repair:15 - 30 mins
ToolsScrew drivers
CustomerLarry from Republican City NE
Ice maker door failed to close letting ice melt
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
|