ORDER BY MOD #FAN MOTOR S.S. 120V VIETNAM (COV.PLAST)

PartSelect Number PS11749867

This evaporator fan motor is located in the back of the freezer, and circulates air over the refrigerator coils. These coils will convert the heat into cool air, which is then circulated.

This part works with the following brands: Whirlpool, Admiral, Estate, Inglis, Kenmore, KitchenAid, Roper, Maytag, Crosley, Jenn-Air, Hardwick, Magic Chef, Amana, Caloric & Glenwood.

This part fixes the following symptoms:

  • Fridge too warm.

Compare At

$68.71

You Save

$11.45

Your Price

$57.26
Get this part fast. Average delivery time via regular ground: 1.8 days.

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 3.8 / 5.0, 2 reviews What's this?
1-2 of 2
 

27 of 33 people found this instruction helpful

Parts Used:
  • ORDER BY MOD #FAN MOTOR S.S. 120V VIETNAM (COV.PLAST)
  • Grommet-Motor
Level of Difficulty: Easy
Time to do repair: 30 - 60 mins
Tools: Screw drivers
Customer: Donald from Waco, TX

The freezer section was working fine. Not properly cooling the refrigerator

I looked on line to see what was causes of the problem and determined that it was probably the fan in the freezer not working. I took the back section of the freezer apart and saw the fan was not running. I checked the parts on line and found that it was availiable and ordered a new fan motor. The blade looked fine, but I ordered a grommet anyway to ensure that there was no vibration problems causing the fan motor to go out. When the fan motor arrived, I began disconnecting the old one after unpluging the refridgerator and noting the terminals for the wires. The wire terminals were in a slightly different location, but reasoned out which wire belonged to the correct location. I pulled the old fan motor out, switched out the fan blade and grommet and re-incerted the new fan motor. I reconnected the wires and re-assembled the rear wall of the freezer. I plugged in the refridgerator and wa-la! It worked.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

7 of 9 people found this instruction helpful

Parts Used:
  • ORDER BY MOD #FAN MOTOR S.S. 120V VIETNAM (COV.PLAST)
Level of Difficulty: Really Easy
Time to do repair: 15 - 30 mins
Tools: Nutdriver, Pliers, Screw drivers
Customer: Raymond from Cedar Falls, IA

Blower motor expired