Dryer indicated error codeF23 after 1 minute of operation
I followed the test guidance on the tech sheet (located behind the front lower cover). According to it, F23 was a short in the outlet thermistor. The thermistor tested good along with all the other replaceable temp related devices. I then started a general diagnostic following the steps in the tech guide. The dryer failed a mo
... Read moretor control step which indicated a bad control board. Replacing the board (after it arrived) took less than 5 minutes and was 100% plug and play. The most difficult part was ensuring that the test leads for the multimeter were on the correct test points. If you are not confident in using a multimeter, I would not recommend you perform this level of repair.
Read less
Scott from Manassas, VA
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
32 of 80 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
< Prev
1
Next >
Questions and Answers
Ask our experts a question about this part and we'll get back to you as soon as possible!
13 questions answered by our experts.
Sort by:
< Prev
1
2
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
David
December 13, 2017
I need a control panel. Error message f01. What is the correct part number?
For model number wed9200sq1
Hi David, Thank you for the question. The F01 indicates a failed electronic machine control board, Part Number: PS2580566. Good luck with the repair!
15 people found this helpful.
Was this helpful?
Thank you for voting!
Mike
December 6, 2018
Hi i get an f70 error code on my dryer and from reading online it sounds like the control board is defective. Does that sound right? I would hate to replace it and have the error code still be there.. mike
For model number wgd9400sz2
Hello Mike, thank you for your question. Usually that error code is in relation to an error between the control panel and the control board. You can unplug the unit for about 20 minutes and plug it back in and see if that resolves the issue. If that doesn't help, we would recommend checking the connections between the board and control panel to see if there are any breaks or burns on the wire connections. If everything looks good there the control board would be the first part we would recommend replacing. I hope this helps.
2 people found this helpful.
Was this helpful?
Thank you for voting!
Patrick
March 27, 2019
Is error code f01 exclusively for the control board?
For model number MEDE300VF0
Hi Patrick,
Thank you for your question. Yes, the F01 error codes indicates a failed electronic control board. I hope this helps. Thank you and have a great day!
2 people found this helpful.
Was this helpful?
Thank you for voting!
Dawn
September 23, 2017
We need a control panel for our duet dryer
For model number WED9300VUO
Hello Dawn, thank you for contacting us. The control panel for this model has been discontinued by the manufacturer and is no longer available. You can still get the control boards if you needed those. They are part PS2580566. Good luck with the repair!
I got a f01 error. I was told it is the control board. Do you have one. It is a Kenmore gas dryer.
For model number Model # 110.97892602
Hello Carlos and thank you for writing.
Yes, we do. Control board Part Number: PS11749572 is in the list of compatible items for your model. We hope this helps. Please contact us anytime.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Alan
September 3, 2022
Received a F01 error code on my Maytag dryer. Removed control board and confirmed it had failed. (Blackened area under one section of circuit board). Have ordered PartSelect Number PS11749572 as replacement. Is there anything else I should check before installing the new board? Would hate to turn dryer on and find this caused the the new board to also fail.
For model number YMEDE300VF1
Hello Alan, thank you for your question. F01 means that the main relay control board inside your control panel has failed and your control board would need to be replaced to fix the issue. According to our research there is nothing else that would cause this problem. We hope this helps.
1 person found this helpful.
Was this helpful?
Thank you for voting!
TOM
September 18, 2023
I have a Kenmore Elite Smartheat QuietPak 4 dryer, Type: CADT – ELE 2406024 – EL54, Model No: 110.C87872602.
The dryer is overheating. I was advised to buy a replacement thermostat (I see on your website part number PartSelect #: PS11746740, Manufacturer #: WP8577274).
However, when I checked that I was planning to order the correct part, it advised me that it was better to buy the main control board (as well).
On your website I see a main control board with the details PartSelect Number PS11749572
Manufacturer Part Number WPW10174745. Please could you tell me whether this should be correct for my machine? Thank you for your help! Tom
For model number 87872602
Hi Tom, thank you for contacting us. Yes, both parts you have mentioned are compatible with your model. Overheating can be fixed by replacing the thermistor, part number PS11746740, first. The control board, part number PS11749572, should only be replaced if the issue persists. We hope that helps!
If i order part number wpw10174745 will the electrical plug ins match the old board?
For model number WED9400SW1
Hi David,
Thank you for your question. Yes, where this electronic control board is coming up under model number WED9400SW1, it would be the correct part for your appliance. I hope this helps. Thank you and have a great day!
Was this helpful?
Thank you for voting!
Joan
November 27, 2018
My stove control panel went out. I need part no. W10181766 and cannot find it.
Hello Joan, thank you for contacting us, In order for us to locate the correct parts and repair information we will require the model number of the unit. W10181766 is not showing to be a valid number. Once you have located the model number please feel free to resubmit the question and we will be happy to help you. Look forward to hearing from you!
Was this helpful?
Thank you for voting!
Dan
December 18, 2017
My dryer stopped running. I found that the thermal fuse was open, so i replaced it. Ran the diagnostics and got f25 error code, indicating a shorted inlet thermistor. I installed a new one, but i still get the f25 code. What are the other possible failures?
For model number 11087872603
Hello Dan, Thank you for your inquiry. A F25 error can also indicate that the main control board cannot detect the speed of the drive motor. First check the bearings on the tub for any wear. Then check for a loose connection in the wiring between the drive motor and both of the electronic control boards. You can test all three parts with a multimeter for continuity as well. Hope this helps!
Was this helpful?