I broke the ceramic tray on my Advantium Oven
The repair was simple -- I just placed the ceramic tray. It took longer to find the part! They had the best price, and my part came quickly!
Parts Used:
Cooking Tray
  • Mendi from Wentzville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven shut down when TCO (thermostat) detected overheat. Once cutoff, it has to be replaced not reset.
The spacesaver is mounted over the stovetop. I removed the oven, then removed all the screws from the cover. Removed the cover and located the TCO and removed the wiring and the TCO. Ordered the part VIA internet and replaced it . It helps a little that I was Radar tec. and taught Electronics for 10 years and repaired lots of Microwaves. However anyone could do it just watch what you remove and replace in reverse order.
Parts Used:
Oven Cavity Temperature Cut-Out
  • R C from Eglin Air Force Base, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Wrench (Adjustable)
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No cooking Power
Had to remove outer cover (special screws involved). Found the correct part at PartSelect.Com and it arrived 3 days later as promissed.

This oven has diffcult electrical connections at switch to get disconnected. I found it easier with the sw loose and in hand so that the connectors can be released with a small screwdriver.

One has to this in order to test the part wirh an ohm meter. I found the sw did not close but remained open and thus caused the oven not to function.

Removing interconnect switch is tricky but not difficult.

Outer cover replacement is not as easy as it should be, especially the sides.

All is well and working.

Microwaves are simple devices if you are know how to read and understand schemetic diagrams.
Parts Used:
Primary Door Interlock Switch
  • Norbert from Minnetonka, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable did not turn when anything on top
Turn off the circuit breaker to the microwave. Remove the 4 black wood screws that secure the microwave to the cabinet. Pull the microwave all the way out and set it on something that leaves you access to the middle access panel on the bottom. Remove the access panel on the bottom that has one screw. Unhook the 2 cables to the motor remembering which color goes where. Remove the 2 screws for the motor and replace the motor. Finish up in reverse...
Parts Used:
Motor, Turntable
  • Javin from Waltham, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lack of power to unit
This is the second time replacing this fuse, last time was exactly one year ago. The first time I replaced it, I removed the oven from the wall & disassembled a number of things to reach the culprit. This time I left the oven mounted & was able to access the 2 grille mounting screws on the top of the grille & remove it. Next comes the black plastic air deflector held by two screws & is mounted in front & on the right, it is shown on the parts list just above part #1434. After removing it, remove the two silver cover screws in the front, this cover also doesn't have a part # but is shown to the right of part #1410. At this point you can lift this cover enough to access the fuse which is on the left & held in place by one tiny screw through the clamp at the top, (careful not to drop it when removing). PS: Don't forget to cut the power to the microwave before starting!
Parts Used:
Oven Cavity Temperature Cut-Out
  • Neil from Williston, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
after 3-4 minutes microwave display would blink and unit would just cut out.
This was the second time I've had to open up the microwave. 1st time display would blank out but system would continue to operate. Found solder connections on board to LED display were defective. Resoldered and unit was fine. This time I found the connection to the oven cavity temp cut-off was bad, plastic connection cover melted. When unit operated bottom lead and wire would heat up. Couldn't measure a Discernable distance so either wire or connector connection surface was not sufficient to carry the current. 1st replaced sensor still wire heated up. Replaced connector and there was no sign how heat from resistances.
Parts Used:
Oven Cavity Temperature Cut-Out
  • Larry from Brookfield, CT
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Wrench set
12 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blown fuse in microwave
One small Phillips screwdriver and one fuse puller (I used cord). Unplug unit. Remove the two screws on the vent face plate. Remove the one screw on the panel assembly. Gently let hang. Pull the fuse located on the upper left wall. Replace fuse. Reassemble.
Parts Used:
FUSE
  • Frank from VIPER, KY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave would not heat
First remove all screws holding on outer metal casing of microwave. Next remove the back and bottom metal pieces. You will then be able to pull aside the outer casing so you can access the door switches. Check each switch with an ohm meter in both the open position and with the switch closed. If the ohm meter reads the same in both the open and closed position, the switch is bad. Check the top switch first. Replace switch and reassemble. Cheap fix for a costly microwave. Great customer service at Parts Select!
Parts Used:
Primary Door Interlock Switch
  • John from Erie, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
13 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave does not have power at all, though outlet has power
unplugged power cable / unhooked front vent / unscrew the monitor panel / slide up to dislodge / take the fuse out and put in the new one in / fuse is located right in front of monitor panel once its open might be covered by wirings / you can unpin the cables from the panel to make it easier for you just make sure to put it back properly or you can have somebody hold the panel for you. Installing the fuse is easy waiting for the parts is crazy......
Parts Used:
FUSE
  • Ronie from BRIARWOOD, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave went totaly blank - No power
Disassembled the front cover, found slow blow fuses, then replaced with microwave fuses 250V-20Amp. Utilized a few fuses to pin point the problem, Microwave functions all worked except the express feature, made an assumption after using a tester that it was the high voltage capacitor and the diode that attaches. Replaced both, plugged in and tested. Worked! reinstalled the unit. Sucessfull for the past month.
Parts Used:
High Voltage Capacitor Diode Cable
  • Mark from Bushwood, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Wrench set
8 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Opened door to get food put more food in closed door it wouldnt work
Everything worked on the display light inside worked but when you closed the door and set time it would start counting down but not heating nor would the turntable turn. Started reading troubleshooting chart and first thing I did was removed the cover and checked door switches and found primary door switch wasn't working so I ordered a new one installed it and it worked. Anyone doing this has to be very careful because of the stored energy in the capacitor is strong enough to kill.
My micro is only 2 years old so I was hoping it wasn't anything major.
Parts Used:
Primary Door Interlock Switch
  • Henry Totten from GROVES, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior lamp burned out
Unscrewed the vent at top of microwave exposing small access to bulb. The access to this was very limited so that was the major issue in changing the bulb. You needed small hands to do the job.
Parts Used:
Light Bulb
  • Patricia from Tarpon Springs, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mICROWAVE WOULD NOT HEAT
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
Parts Used:
Primary Door Interlock Switch
  • Peter from Bessemer, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave not heating
The GE appliance technician replaced the magnetron, HV capacitor, and diode without luck but only charged me the service call, not for the rest. He however told me the only item left would be the HV transformer. Having watched the nearly 2 hour teardown and rebuild for the parts, it gave me the knowledge needed to attempt the HV Transformer. Having received the transformer, I tore into the micro removing the old TF. To my dismay, the old TF tested good (per advice from the internet checking the prim and sec resistance values... they also came close to the new TF. So I elected to dig out the schematic and troubleshooting flowchart hidden inside my micro. All things led back to a door switch which checked bad... part which I didn't have. Reassembled micro, ordered switch from Parts Select and installed in about 1/2 hour. Micro work great now. Only if the GE tech would have followed the flow-chart! I ended up returning the HV Transformer since it wasn't used and not needed. Had to absorb shipping costs.
Parts Used:
H.V. TRANFORMER
  • Ralph from Acworth, GA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked glass, light always stays on
Problem 1: cracked outer glass
1. Remove the outer glass assembly using the four screws along the top and lifting out/up, be very careful it doesn't fall off and break on the floor. Hold the handle while removing the last screw, it can fall easily.
2. Remove the handle using the 2 long screws on the back side which feed through 2 small metal plates that were previously holding the door onto the main cavity.
(3) If there is broken glass, it helps to remove the metal ledge the glass was on using the screws underneath and clean out all broken glass fragments, to do this you may have to remove the vent panel below it to get screwdriver access.
4. Assembling the new glass panel is the same steps backwards, should be obvious.

Problem 2: Light always stays on
1. Remove the door switch panel on the left side of the microwave, 1 screw.
2. Remove the right access panel on the right side of the microwave, this is large and has many screws, and a couple also need to be removed on top.
** Don't touch any wires when doing all this, and make sure you are grounded and don't produce an electrostatic shock. **
3. Manually toggle the door latch catchers on either side (just the plastic, don't touch any wires), at the same time, and see if the light turns off. If it does, the door latches might not be putting enough pressure, they may be cracked or need to be replaced.
4. Sometimes the switches get dislodged, for example if someone slammed the microwave shut. Try nudging the switch, or one of the connectors, slightly towards the door side, or tapping it from behind with a screwdriver. If it was loose you might get an audible click when it goes back into place.

Note: if the microwave light always stays on, it eventually might shut off after a long time. Power cycle the microwave before doing the tests above, so the light is on when you toggle the door latch switches.
Parts Used:
Exterior Door Glass DOOR GLASS MOUNT - BLACK CUSHION PANEL-CONTROL MOUNTING WASHER - TEFLON
  • Richard from Arroyo grande, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!