Not getting cold in lower Refrigerator
Watch the video provided by PartSelect and did exactly the same percedure. Shows what screws to remove and how to remove and replace the part. The freezer compartment was iced up quite a bit so defrosted it before installing part.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Charles from Wallingford, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Heater not coming on - coil frosting up- freezer and Refrig. warm
The instructions given to me by part Select were very good.I replaced the Timer- checked the heater with oham meter it was good- checked the door weather striping it was good and replaced the thermostat with new .So at this point I may need to call a professional unless some one has another solution.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from merrillville, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Unit keep cutting off
Ordered the new part-Unplugged the refrigerator - took off the cover over the defective timer - put in the new part put the cover back on - plugged the refrigerator back in - so far, so good!~
Parts Used:
Defrost Timer - 60Hz 120V
  • Ed from Memphis, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
won't start repaced the run capacitor didn't solve the problem so I ordered a defrost timer
I watched the videos (they really help) and followed the steps. Everything went smooth with no surprises
Parts Used:
Run Capacitor
  • Curtis from Winlock, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
Was this instruction helpful to you?
Thank you for voting!
has lights,no fan or compressor
jump thermostat,fan and compressor came on, ordered thermo from this excllent parts supplier, part came in 4 days later, it was exact replacement, works exactly right!
Parts Used:
Cold Control Thermostat
  • francis from arlington, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refridgerator not geting cold.
Just followed the online instruction video .It was very easy.
Parts Used:
Defrost Timer - 60Hz 120V
  • VINCENT from DEPTFORD, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer cold--frig was warm
You guys at Partselect are the best!!! Went to your site, typed in my appliance symptoms, and received possible fixes. Ordered the suggested parts (under $50) on a Sunday night and got em Tuesday am. Installed the easiest one first and Voila!!!! Frig is working great. Thanks Bob S
Parts Used:
Defrost Timer - 60Hz 120V
  • Robert from Chicago, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator section not cooling
Checked defrost timer. It was a shocker: it was completely burnt out. Replaced it with the new part very easily. I thought now it would defrost properly but unfortunately the thermostat also was shot. I had ordered it along with the timer just in case. It was not expensive at all and I saved time but having it with me when I replaced the timer. NOW ALL IS WELL AND REFRIGERATOR SECTION COLLING PROPERLY. THANKS TO VIDEO AND PARTSELECT.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Anant from Stone Mountain, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Frig Section Too Warm,Freezer Ok
Using your online troubleshooter, it was probably the defrost timer and/or the defrost thermostat. Both cheap so I ordered both. The online repair videos showed how to replace those parts. Replaced the timer first with no problems. Removed the panel at the freezer back an saw a streak of black smoke on the white panel wall above the thermostat. Good chance this was the failure point. Video also showed how to replace this unit without any problem. Set the temperature control and let the frig run over night. Problem solved!frig at 38d and freezer at 0d.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • LANCE from AURORA, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling
Remove 4 screws that hold up overhead controls, this is also the part that holds the light. Unplug the timer and replace. Super simple and runs great now. After you plug it in it may take a few minutes to kick on the compressor but it will. Also I was pleased it was a factory Frigidare part. Price was right.
Parts Used:
Defrost Timer - 60Hz 120V
  • Scott from Norman, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
no heat when drying
Replaced thermo-fuse
Parts Used:
Door Rack Freezer
  • Glen from North Tonawanda, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
It would freeze up or not cool at all, depended where the clock stopped.
Removed the lower trim panel from front of fridg. and loosened two screws enough to turn it about 1/4 inch so the screw heads were in the larger holes. Pulled it out disconnected the wire connector and transfered the heat shield and screws to the new clock, connected the wire connector and aligned the screws. tightened them and job done. Has worked like new sense. Thanks Roger
Parts Used:
Defrost Timer - 60Hz 120V
  • Roger from Owatonna, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
fridge not cold stays running
unplug fridge,Then take rack out n remove the 2 screws on the icemaker set aside,then remove 2 screws on the back panel, cut wires n splice in new part! put back the same.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Joseph from Deland, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refrig would not defrost
Diagnosis: used wiring diagram attached to frig and determined cause could be wiring, heater element, thermostat or timer. After completely defrosting the frig (turned it off) I removed the rear cover in the freezer and looked for an obvious problem. None seen. Removed temperature select pod from the frig box and looked for obvious problems. None seen but defrost timer appeared poorly made. Repair: Since I had no practical way of checking the defrost cycle in operation, I checked probable failures on the Part Select website and saw defrost timer as most probable. I ordered the timer. Installed it. Waited a few days to make sure the frig went through a few defrost cycles then removed the freezer rear cover. There was no excessive frost buildup so I'm reasonably sure the repair was successful.
Parts Used:
Defrost Timer - 60Hz 120V
  • Robert from Jacksonville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer and main compartment had wide temperature variations
I first thought the defroster heater broke - took the back wall of the freezer off and cooling fins were fine. Then took the defroster timer out and opened it up. The contacts were badly burnt so the compressor and fan ran during only part of the cooling cycle. Replacing the timer took less than 5 minutes - turn off the power, remove one screw to take out the control box, cut the ground wire (new timer housing is plastic and does not have a ground connection), remove two screws to unmount the timer, unplug the old timer, plug in the new timer, fasten with two screws, put the control unit in and fasten with one screw, turn power back on.
Parts Used:
Defrost Timer - 60Hz 120V
  • Joseph from Tullahoma, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the WRT15A0AW2