Models > UMC5200BAW > Instructions

UMC5200BAW Microwave - Instructions

All Instructions for the UMC5200BAW
1 - 14 of 14
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
microwave oven blew fuse
First I removed upper front grill by removing two Philips head screws on top and pulling off. This exposed the Philips head screw which holds control panel in place. After removing screw I pushed up on panel and it came off to expose fuse. With needle nose pliers I removed old fuse and again with pliers held new fuse in position. With the help of a bladed screwdriver, I pushed new fuse into holder, then replaced panel, screw and grill. This took less than 15 minutes even as one of the wires on control panel pulled out of connection and took some time to locate where to reconnect, otherwise was an easy fix
.
Parts Used:
Ceramic Fuse - 20 amp
  • tad from tamarack, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
24 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microve stopped working
Jenn-Air Microwave would not turn on. Clock worked , light worked, timer worked and would count down .I changed' Part #0813140 Switch, Micr} cost $8.99 plus shippingNow it works Thank You for good advise
Parts Used:
Ceramic Fuse - 20 amp
  • Denice from Montgomery, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
12 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Died while heating lasagna
Removed 4 small star head screws from back of microwave, lifted body off, removed blown fuse and replaced with new one (found where cord enters). This model is stainless inside and out and I like it a lot. It is also sold by Daewoo and a few other manufacturers.
Parts Used:
Ceramic Fuse - 20 amp
  • connie from madison, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Buzzing noise, no heating of food
Removed control panel, discharged HV capacitor. Removed old diode, tested to confirm failure. Replaced part. Other than the removal of the panel swapping the part was almost as easy as replacing a light bulb.
Parts Used:
High-Voltage Diode
  • Ted from Hudson, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave went pop and nothing would work.
I mistakenly thought I had to remove the microwave to get to the back, not so. I would have had access to what I needed to unscrew; but I have to admit the hassle of taking it down and putting it back equals having to work on it attached to the shelf-your call on how you do this. I unscrewed the front top to remove the vent piece that is across the top front of the microwave. This will reveal the control panel screw. (While you have the vent removed you might want to clean the vent and the exposed filter.) carefully lift and pull out control panel. I unplugged a piece as the wires were tied tight. It will not completely detach, so carefully tip it back from exposed insides. The fuse is not clear but white with silver ends so look in upper right for it. I popped it out and replaced it. Replugged the wired part to cover and carefully fit tabs in and slide down to secre. Replace screw, replace vent piece and secure screws on top of microwave. I plugged it in to test before putting it back above my stove.
Parts Used:
Ceramic Fuse - 20 amp
  • Deborah from STRUM, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Appears to work, but food not heated
The high voltage tired was shorted. I replaced it with a new one, but that did not solve the problem.

You can test the high voltage tired with a voltmeter and a 9 V battery. Search Search for it on YouTube.

You can also test the high voltage capacitor, the high-voltage transformer, and the magnetron with a multi meter. Search for the procedures on YouTube.

I tested all these high-voltage components with a low-voltage multi meter, and they all checked out OK (after replacing the diode). However the microwave still did not heat food.

When working on a microwave it is important to unplug it and also discharge the high voltage capacitor. The capacitor has a 10 megaohm resister to automatically discharge itself, but it may have failed – – so discharge it manually.

In the end I ordered a new microwave.
Parts Used:
High-Voltage Diode
  • Joel from CAMBRIDGE, MA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
11 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would continue to run even when door was open. (even if no time was left on timer)
Unplugged Microwave, Removed vent cover (2 screws on top of microwave, then slide cover to the left, then forward) Removed control panel (1 screw at top of panel) then removed the two screws that hold in the door switch assembly. (these you will only see by opening the microwave). Located lower door switch, removed connecting wires, and pulled switch by releasing small plastic tab which held it in. Put new switch in place, reconnected wires, then reconnected door switch assembly. Reconnected control panel, and then put the vent cover back on. Tested microwave and it no longer runs when the door is open. Super easy fix, and was done in under 5 minutes.
Parts Used:
Micro Switch
  • TIFFINI from BUFFALO, WY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable Quit
Snipped four corners off inspection panel,removed one phillips screw and two elect. Connections. Reverse process.
Parts Used:
MOTOR SYNCHRONOUS;SSM-16
  • RICHARD from OKLAHOMA CITY, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No power to any microwave functions
Access is via RT. SIDE Panel as you face microwave. There are three screws on the bottom right edge to loosen. After that the side panel slips down and off. the fuse is located in the rear near where the power cord comes in. It is the white ceramic tube 1/4" in dia. and 1-1/2" long. Pull it out like any fuse and replace with new one. Reassemble and you are done!
Parts Used:
Ceramic Fuse - 20 amp
  • Richard from CALIFORNIA, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thermostat failed because rivet was loose on connector blade; caused overheated wiring.
Replaced the the thermostat located above the magnetron.
Parts Used:
THERMOSTAT;NT-101,250V 1
  • Ray from GRANBURY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave stopped working - would not heat up
I removed the outer cover and exposed the inner workings. I watched a video on partselect.com to show how to remove and replace the Diode. I followed the instructions and it was very easy to replace.

Unfortunately, the diode was only part of the issue. I ended up replacing the High Voltage capacitor and Magnetron also. Those were a little more complicated but still easy to do.

Now the Microwave works just like new! Cost me less than $100 for all parts.
Parts Used:
High-Voltage Diode
  • louis from PARRISH, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
4 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blown heater element
Replaced with new microwave. Acquired the same model so it would fit in the space and be covered by the frame border. Screwed base and vent protector in place , slid it all into the space and screwed on the frame. Had plugged it in for testing . Turned it on and am using it today....bought a 4yr extension warranty. Hope I don,t have to repair or replace again...Originally, I had needed a roller guide for under the spinning plate. Did replace it but a few days later the whole microwave stopped because of the heater element.
Parts Used:
ROLLR-GIDE
  • Dr. John from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cooking tray shattered
My daughter was trying to run the microwave timer and ended up nuking the cooking tray, which shattered. First web place I found wanted 55$ for this tray and this site sold it for 19.99. It shipped super quickly. I am very pleased with this company!
Parts Used:
TRAY-COOKING;JVM-1860,GL
  • Valerie from Rock Springs, WY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Power cuts in and out; runs for a few secs then powers off
Disconnected power and removed Microwave housing cover, observed burned end plastic connector of wire connecting to the thermostat (or thermal overload sensor); slightly wiggle one of the 2 wires to the thermostat would cause microwave power to cut out (when plugged in power). When powered on, I would try to run it but power cuts out after just a few seconds. Removed the 2 wires from the old thermostat, removed the 2 screws that fasten down the thermostat, replaced with new thermostat and reapplied the 2 screws; cut off burned part of wire and resolder to new wire connector; reconnect both wires to new thermostat and reinstall MW housing cover. MW works good as new again. Thank you PartSelect!
Parts Used:
THERMOSTAT;NT-101,250V 1
  • Vinh from Houston, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the UMC5200BAW