Door handle broke off
First I removed the top screws, then I slide it off the lower screw that is hidden behind the handle. I replaced the handle by sliding it onto the bottem first then attaching it onto the top with the two top screws.
Parts Used:
Door Handle
  • Lisa from Linton, ND
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
198 of 214 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator coil kept freezing up, refridgerator warm.
This was the second part I tried. The defrost timer was first, but that did not fix it. To do this I had to remove the ice maker and the back plate of the freezer. Then I defrosted the coil and cut the wires. stripped them back and installed the new thermostat. re-assembled and tested. has been working great ever since.
Parts Used:
Defrost Thermostat
  • Greg from Hanover Township, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
181 of 199 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not run but interior light was on.
I unplugged the refrigerator, then opened the door and removed four screws holding the plastic electrical panel to the interior top of the main refrigerator compartment and noticed the cold control was corroded badly, apparently from moisture in the panel. I ordered a new one from partselect.com. When it arrived the next day, I then pulled off the control knob, unclipped the cold control, unplugged the three wires to the control, then removed the styrofoam insulation blocks holding the thermocouple wire and then removed the thermocouple wire to complete the removal. I then reversed the process to install the new thermostat and control. That is repositioned the thermocouple wire, put the insulation blocks back to hold the wire, then replugged the three electrical wires, clipped the control back and pushed the control knob back on and finally screwed the panel back to the top of the main compartment and plugged the refrigerator electrical cord back in to provide current to the refrigerator. It immediately started up and ran fine. Total time - about 8 minutes.
Parts Used:
Cold Control Thermostat
  • Bruce from Alton, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
178 of 231 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold, not defrosting, refrigerator not cold
This was extremely easy. Took off the control box (housing that covers the light bulb, has the temp control dial on it) and easily replaced the defrost timer. Then, emptied freezer, took off cover at the back of the freezer. Disconnected old defrost thermostat, attached new one, reattached back cover, melted accumulated ice, put stuff back in. Started up. Been running great ever since. No more ice accumulation in freezer. Temp stays constant. Great service from PartSelect, saved lots of money. This job is easy on this fridge, go for it!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Mark from Tallahassee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
83 of 91 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold. Fridge too warm.
Ice build up to back of freezer. Fridge way too warm for preserving food/drinks. Unplugged fridge and de-thaw freezer with a hair dryer. Removed and replaced defrost timer in the fridge area which simply unscrews and plugs in. The video supplied by PartSelect worked well for this.

The Defrost Thermostat required a bit more work as it is accessed through the freezer compartment. I had to remove two screws to get the back cover that houses the fan removed. Then you cut the wires from the old Thermostat and remove it before splicing in the new Defrost Thermostat using the supplied crimps and matching the wire colors. It is useful to have a good wire stripper/crimper ready to make the job simple (I bought a pro one for $28 at Home Depot but they can be found cheaper). Also, there is a bit of heat shrink material included to protect the wires from moisture so a heat-gun will do the trick or Good quality electricians tape will also cut it.

I then sparked it up and it works as new. :)
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Marc from Sumas, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
52 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Parts Used:
Defrost Timer - 60Hz 120V
  • Tad from Lancaster, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
46 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I pulled the refridgerator door open and the handle snapped off.
This repair was very easy and took less than five minutes. I used the same screws that were on the fridge to put the handle in place. All I needed was a screwdriver. I would also like to add that when I ordered this part it was shipped the same exact day and I received it the next day. It was incredibly fast and I will use them again in the future. I recommend this company to those who need to replace or repair a part. Thanks PartSelect!
Parts Used:
Door Handle
  • Sara from Warrensburg, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
35 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Handle on Main Door
Unscrewed the old screws and removed broken piece of handle. Put new screws in for handle to latch in. Swung handle in place and put the 2 special screws in top of handle. Job done. With the correct parts from Parts Select The replacement was a breeze. Thanks for your speedy delivery and support. I will definitely continue to get all my various appliance parts from you

Respectfully

Roy
Parts Used:
Screw Screw - Kit of Four Screw Door Handle Handle Mounting Block
  • Roy F from Oakdale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
32 of 40 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wouldn't defrost
First, I replaced the defrost timer, really easy, 4 screws popped the cover of the electronic area (top of refrigerator compartment) took it out and plugged in the new time. Unit still would not defrost, so replaced the thermostat as well. Bit harder, removed ice maker, 2 screws, back plate from freezer, 4 screws. Thermostat was clamped to a copper tube- the original had one of the wires hanging out of it- cut the wires and crimped the new wires on, shrunk the plastic tube with blow dryer over the wires (taped them for good measure) and so far so good. Learned most of this through these tips, so keep reading if this isn't your problem, just save myself $1000 on a new refrifgerator...
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Patrick from Gansevoort, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
30 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Parts Used:
Defrost Timer - 60Hz 120V
  • Todd from pottstown, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.
Parts Used:
Defrost Timer - 60Hz 120V
  • Erle from Boise, ID
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Parts Used:
Defrost Timer - 60Hz 120V
  • Miles from Longview, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
22 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Socket short
- Unsnapped old light socket from top of Frig
- Disconnected elect wires
- Reconnected elect wires to new light socket
- Snapped new socket in place
- Done in less than 2 min.
Parts Used:
Light Socket
  • Rebecca from Gautier, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the shelf bar broke
I popped the new one in. My cat could have done it
Parts Used:
Door Rack - White
  • Jeff from New Yrok, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
18 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
just quit working
Bought a new
capacitor.
Parts Used:
Run Capacitor
  • Denise from Lowell, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!