Sometimes the condenser fan would start causing the refrigerator to overheat.

  • Customer: Tom from Franklin WI
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 91 of 94 people found this instruction helpful
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new

Lights inside refrigerator not working

  • Customer: Clint from Rayville MO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 41 of 49 people found this instruction helpful
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.

Thermostat ceased to function. Fridge very cold.

  • Customer: Paul from Millboro VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 25 of 31 people found this instruction helpful
I removed control knobs and a couple of screws and forced the assembly down enough to remove the old thermostat, and insert the new one. Lucky me it was a identical replacement item. Job took about an hour.

noisy fan motor

  • Customer: robert from nashotah WI
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Socket set
  • 17 of 20 people found this instruction helpful
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.

Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.

  • Customer: Florentino from Windsor Locks CT
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 16 of 21 people found this instruction helpful
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.

The light switch on the refridgerator broke - no light.

  • Customer: David from Albany OR
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 16 of 25 people found this instruction helpful
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!

The old motor wouldn't turn the fan.

  • Customer: Bob from Hesston KS
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set, Wrench set
  • 12 of 14 people found this instruction helpful
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.

overload relay switch/bad compressor--buzzing sound, ends with click, retries

  • Customer: Nathan from Garland TX
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 11 of 14 people found this instruction helpful
Remove back cover. Disconnect power. Pull out overload switch off compressor. Remove capacitor. The overload switch i ordered came with instructions. What took the most time was figuring out if i dared installing it the way i thought best. The instructions, in my instance, were incorrect. My overload switch didn't have a terminal #1. Long story short, i looked at the circuit diagram it came with, and based on process of elimination based on terminal sizes, I put it together. But the instructions weren't accurate. All in all for the average DIY, not a bad repair at all. I am still afraid that my problem is the compressor, b/c even after the new part is installed it still occasionally tries starting but can't, and keeps retrying until it does. It is either a faulty relay switch or a faulty compressor. We'll see which one wins.

Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.

  • Customer: David from Cedarville OH
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Screw drivers, Socket set
  • 10 of 11 people found this instruction helpful
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.

Freezer and Fridge wouldnt cool

  • Customer: Janet from Hillsboro OR
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set, Wrench(Adjustable)
  • 9 of 10 people found this instruction helpful
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!

Fridge stopped working

  • Customer: Dan from Sumner WA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 8 of 9 people found this instruction helpful
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.

door shelf retainer bars were broken

  • Customer: BettyJo from Culpeper VA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 8 of 9 people found this instruction helpful
I received the door shelf bars. They were 26 inches. I used a hack saw and cut them to 22 inches. Put them on.
Perfect fit!!

fan had stopped-freezer not performing etc.

  • Customer: George from Glenwood MN
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers
  • 7 of 7 people found this instruction helpful
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!

Condenser fan motor seized

  • Customer: Benjamin from Daytona Beach FL
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers
  • 7 of 7 people found this instruction helpful
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.

freezer will not freeze or cool the ice box

  • Customer: David from Choctaw OK
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 7 of 9 people found this instruction helpful
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson