Models > RS22AQXGW03 > Instructions

RS22AQXGW03 Roper Refrigerator - Instructions

All Instructions for the RS22AQXGW03
76 - 90 of 1508
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken Shelf Bracket
Removed food itmes on broken shelf. Removed old glass shelf cover. Removed broken shelf bracket. Installed new shelf bracket. Intalled new glass shelf cover. Replaced food items back on shelf
Parts Used:
Crisper Cover with Glass
  • Thomas from Leesburg, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
26 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken meat and vegatable draw
a simple replacement
Parts Used:
Refrigerator Crisper Drawer With Handle
  • douglas g. from roanoke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the original auger was plastic and broke
Pretty easy to replace..just take your time with the ice crusher but the teeth are labeled a..b..and c. This auger is steel so I should have no problems with this breaking. I received this item less than 24 hrs after I ordered it! On Christmas eve...Thanks to all of you
Parts Used:
Ice Auger Kit
  • scott from Cocoa, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
motor coupling weld broken
Removed four screws from ice maker motor/light support.Then unplugged electrical plug from side of freezer.Used two slip joint pliers to remove coupler from motor shaft. installed new coupler to shaft hand tight as will tighten as motor is run.Then reversed tear down order.
Ice dispenser works better than when we first got the refrigerator
Parts Used:
Ice Dispenser Motor Coupling
  • HAROLD from SPRING HOPE, NC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door fails to close on its own like it is designed to.
The design of this refrigerator door (it's a side-by-side) is somewhat unbelievable. The door is designed to hold things, yet when you do the weight of the door wears out the lower door cams. The cams are designed to "complete the door closing", i.e. when you gently push on the door the cam mechanism takes over. When the cams wear, the door fails to close. Note to others - you may mistakenly think that the failure of the door to close is related to the seal; it is not.

The repair is quite easy; remove the upper cover, using a not driver (socket), then remove the upper door bracket. Make sure you hold the door or have someone else hold it. After the fasteners are removed gently lift up on the door and remove it from the lower cam assembly. You will see two plastic cam pieces; one on the lower bracket and one on the door. Both need to be changed to effectively "renew" the door closing mechanism. Once the cams are replaced the door can be reassembled to the refrigerator.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Jay from Oconomowoc, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator was intermittently cooling because thermostat contacts burned away.
Turn off the fridge and unplug the power. Inside the refrigerator unit, remove two plastic panels extending from the front to the rear cooling vent by unscrewing two screws. Gently unhook the thermostat tube from the rear vent.

On the control panel, gently pry off the two control knobs and the front control panel. Remove four screws to drop down the control assembly. Unplug the left electrical connector and unscrew the lever control arm being careful not to bend it. Disconnect the right side electrical connector and you can now remove the control unit to a table to easily work on it.

Undo two screws to remove the thermostat bracket. Undo two more screws to remove the thermostat assembly. Install the new thermostat and reverse the process just described. It takes about 15 minutes if you know what to do ahead of time. You will have to reuse the plastic tube that covers the thermostat sensing tube.
Parts Used:
Thermostat Assembly
  • Dennis from Westlake, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Door would not close
I removed the Ice door front cover on freezer door. Found door pivot was broken. I installed door pivot bracket, and dashpot in kit. I used most of the kit to repair it. The door now works like new. Thanks for the right parts Frank
Parts Used:
Ice Door Kit
  • Frank from Sandy, UT
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
26 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator door wouldn't remain closed
The plastic lower door closing cam was worn down. Replacing it was very simple: remove the top door hinge by unscrewing three nuts; lift the door off the lower hinge; unscrew and remove the lower door hinge; screw the new plastic lower door closing cam on to the new door hinge; screw the new lower door hinge; lift the door back on to the lower door hinge; screw the top door hinge.
Parts Used:
Door Hinge Set Door Cam - Black
  • Thomas from Fairfax, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
26 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
plastic gear broke off - cubes not getting kicked out
removed the three screw holding the broken unit - pulled off the old module.

Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.

Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
Parts Used:
Icemaker Control Assembly
  • Laurence from Middleton, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
23 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fan wasvery noisy.
Removed six screws from cover in the back of the freezer. Removed old fan . Removed power wires from old motor. Unclipped old motor from the mounting bracket. Replaced old motor and reversed the rest of the parts. Done
Parts Used:
Evaporator Fan Motor - 120V 60Hz Evaporator Fan Blade
  • Tracy from Coppers City Bottom, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door failing to close without being pushed shut
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
Parts Used:
Thimble Top Lower Door Closing Cam
  • Kenneth from Greeley, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
25 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noticed fridge not cooling as it should
Removed the lower back panel (10 small screws)Found the condenser motor froze up and not moving air across the cooling coils.So I got a small table fan and set it behind the fridge and it kept the fridge cooling for 3 days till the new fan motor arrived. Removed 3 small screws holding the fan motor in the bracket and unpluged the wiring harness.Removed the fan from old motor and used it on the new motor.Replaced the fan in the bracket and plugged the wiring harness back in. Worked great. Very easy.Did not have to empty fridge because table fan kept coils cool. Ordering part was easy and shipping fast.Great job guys!!
Parts Used:
Condenser Fan Motor
  • Robert from Franklin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
21 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice distribution door broke
At their site was ordering each piece by # and cost and it was adding up to be costly. Went to partselect and was doing the same and up pops the ice door kit. Was a little wary because my original had a heater tape to it. Got the kit and installed not a problem at all. 100% satisfied would recommend to anyone.
Parts Used:
Ice Door Kit
  • David from Winston-Salem, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side freezing everything.
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
Parts Used:
Thermostat Assembly
  • David from Murfreesboro, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
21 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken drawer
Put new drawer in fridge.
Parts Used:
Refrigerator Crisper Drawer With Handle
  • Jason from Farmland, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RS22AQXGW03