Models > PIR23MGTABV > Instructions

PIR23MGTABV General Electric Refrigerator - Instructions

All Instructions for the PIR23MGTABV
1 - 15 of 501
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrigertor water dispenser not working BUT ice machine is working
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo the connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refreigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explantion. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call which can now be used to take the family to dinner after your "exhausting" 15 minute workout of removing about 10 screws and wheeling the unit in and out of place. Writing this article took longer! My 4 year old worked harder holding the flash light!
Parts Used:
WATER VALVE WITH GUARD
  • ralph from bristow, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
1023 of 1135 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
my refigerator was warm but the freezer was cold and working correcttly
I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.

I went on line to see if there were others having this same problem and found that there were many with the same problem.

After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.

I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
Parts Used:
Temperature Sensor
  • michele from North Smithfield, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
272 of 342 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser not operating
Model includes filtered ice maker and water dispenser from front of unit. Water maker just suddenly stopped working but ice maker continued to work fine. After some phone calls to trouble shoot at a high level, I figured it was worth a try to buy the replacement part of the most likely culprit and see if it did the trick. Would have cost maybe $150 or more for service tech to make house call, provide the part and do the switch. Buying the part was only $40 and replacement was easy. Remove access panel from behind fridge and identify valve. It has intake water from the filter then has two outbound lines. One to ice maker, one to water dispenser. All function is in one part, but each outbound line has its own functioning valve. Unplug fridge, turn off water supply, disconnect all connections from old valve and reattach to new valve. When re-hooked, be patient in allowing water to re-fill line before coming out of dispenser in front. Likely to doubt it works, but surprised how long it took for water to fill line resevoir.
Parts Used:
WATER VALVE WITH GUARD
  • michael from pennsburg, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Wrench set
192 of 228 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace water filter
Unscrew old filter and remove(counterclockwise). Line up arrow on new filter with arrow on connection housing. Turn clockwise till resistance met. Do not overtighten. Follow directions. Simple.
Parts Used:
Refrigerator Ice and Water Filter
  • Alfred from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
224 of 338 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaky water valve
Unplugged the refrigerator, turned off the water supply, and then removed the back cover/access plate. Observed and made wiring notes to ensure I install the part correctly. Unscrewed the bracket holding the water valve assembly, and lifted it up to see and remove the three water lines (one input, two output). The input or supply line is a compression fitting...just use an adjustable wrench to loosen the nut and lift off the line. Then remove the two output lines by depressing or pushing in on the white plastic rings that surround those two holes ...the lines just slide out, but you have to push in on those rings. Remove the two electrical connectors...just wiggle them off One connector was very stubborn but it eventually came off. Try to be gentle, and pull on the connector heads...not on the electrical wires.
Assemble the lines and electrical connectors on to the new part. The two output water lines just slide in...you dont need to push in on the rings. You'l feel them seat into the valve. Don't worry.
Put it all back the way you found it, turn on the water supply, and plug in the power cord. Check for leaks. I had no leaks and was very pleased. This is so easy a chimp can do it, but let everyone think otherwise! No biggie.
Parts Used:
WATER VALVE WITH GUARD
  • Gary from El Cajon, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
161 of 181 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator too cold
My repair experience was a little more complicated than previous posts, but nothing major. And most importantly replacing the Fresh Food Air Inlet Cover did fix my problem. Here are the steps I followed:
1. You will need to remove a minimum of the top two shelves to get access to the Air Inlet Cover. It runs along the back of the fridge and connects to a hole to the freezer side. It has a little fan inside that sucks the cold air from the freezer and diverts to the top and bottom of the fridge.
2. As mentioned in other posts, there are four screws holding the Inlet Cover in place, 2 lower and 2 upper. To get access to the lower two screws,you simply pop off the lower duct assembly (squeeze the sides). Be careful when removing and installing these screws. If you drop one into the lower duct, you will add a few more steps to the installation to remove more shelves and take out the lower duct to get to where the screw fell. Obviously this happened to me. Not difficult to do, just adds more time.
3. To access the upper two screws I had to remove the top light cover (one screw) and then slide out the top duct/diffuser assy (my name, not GE's).
4. Finally to get clearance to pull out the Inlet Cover, I had to remove the water filter and cover. When you pull away the Inlet Cover, you will see the electrical connection that is simple to disconnect.
5. After I removed my Inlet Cover, it was obvious that it was broken because it rattled and I could peek inside to see that the plastic air diverter/flapper thingy was broken.
6. One final surprise was that the replacement Air Inlet Cover did not exactly match the one I removed. The replacement only had one upper air outlet, while my old one had three upper outlets, left, right and center. I noticed there was a plastic cover over one of the side outlets on the replacement, so I just popped that off and hoped for the best.
7. The replacement Air Inlet Cover Kit came with sticky back insulation that you attach to where the Inlet Cover meet the freezer access hole to make sure snug fit to limit extra cold air leaking into the fridge side.
8. Installation of the replacement Air Inlet Cover was fairly easy, just follow the above steps in reverse and make sure you don't drop any screws.
It's been a couple of weeks since I performed this installation and my fridge has been maintaining temperature perfectly. No more frozen milk or lettuce. The wife is very happy.
Parts Used:
Air Inlet Cover Kit
  • Marc from Orlando, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
154 of 161 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water would only trickle out at water dispenser, but was making ice.
Since it was making ice I new there was water getting to the water valve on the fridge. I found the water valve on the back of the fridge, put a voltage tester on the water dispenser side of the valve, had someone push in the dispenser flap on the front of the fiidge and found there was 120v. That told me that the switch was good and pretty confident that the valve was bad.
Upon reeceiving the replacement valve I removed both electrical leads on the valve remembering witch side goes to which, turned the water line off, removed the water lines, matched them up to the new one, plugged the leads back in on the valve, turned water back on and tested. There will be a little air in the lines, but once that is out the water will flow at a steady stream.
Parts Used:
Refrigerator Ice and Water Filter WATER VALVE WITH GUARD
  • Jim from Livonia, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
161 of 235 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator was getting too cold
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.
Parts Used:
Temperature Sensor
  • Larry from Menomonie, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
143 of 199 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer clod-fridge warm, coils were frosting up cutting off air flow
First unplug then remove all food and the ice cubes from the freezer only..Then removed the traysand then the 2 panel screws. Defrosted the coils with a hair dryer,removed the 2 screws holding the heater and then unplugged the wires from each side.Installed the new heater and now has been fine for 12 days now..The sensor- I just spliced it in the exact way the old sensor was wired.All seems fine so far. Was alot cheaper to buy the parts and install myself than to pay for 1 service call..
Parts Used:
Temperature Sensor Defrost Heater and Bracket Assembly
  • Greg from Windsor, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
105 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Warm freezer and no ice
This story starts with a GE side-by-side refrigerator that has always had wide temperature swings and a temperamental water dispenser. The ice maker was not making ice, and the built in digital thermometer showed it was running warm. I suspected that the heat exchanger was full of dust and so looked there. What I found was that the condenser tank was hot to the touch and the fan wasn’t running. As an experiment, I aimed a fan at the it for a while I saw that the freezer temperature dropped back to normal.
.The fan is marked as 11.2 DC so I checked for voltage at the fan and found some. With three wires and no wiring diagram I wasn’t sure this answered all the questions, but hooking the fan to a 12 volt power supply didn’t get it to spin.
I priced parts at a couple websites before using partselect.com . They also have a good diagram to look at (Sears diagrams are really poor). I ordered the part with 2-day shipping; it arrived on time, was correct and fixed the problem.
Parts Used:
DC Condenser Fan Motor - 12V
  • Paul from Suwanee, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
94 of 125 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water continuously pours out of the icemaker
A week earlier, we had frozen water all over the freezer section which obviously dripped from the icemaker. We turn off the icemaker and cleaned the freezer. Upon turning the icemaker back on, water continuously pours out of the ice tray. This time, even turning off the icemaker does not stop the water from flowing through. I checked and cleaned the water valve, reinstalled it and it still does not work. I had to crimp the water line and even remove the water filter to make sure there will be no water leaks.

When I got the new water valve, installation was a snap as I have already removed the old one. After installing the new valve and putting back the filter, everything is back to normal.

Procedure for removing/replacing the water valve:
(1) Unplug the refrigerator and move it so that you have some working space in the back. If there is a mechanical valve in the water line, close it so that when the hoses are unplugged, there will be no spills. If there is no mechanical water valve, you can simply crimp the hose with a rubber band or a cable tie.
(2) Use an adjustable wrench or a screw driver to remove the screws on the bottom panel. My refrigerator has 4 big screws and 1 small one that is used to anchor the water hose.
(3) Pull the panel up slightly to remove it. The water valve is mounted with one screw at the bottom-left corner.
(4) Use a screwdriver to dismount the water valve.
(5) Unplug the electrical connections to the water valve. My refrigerator has one Brown and one Blue connector. Remember which plug goes to which connector.
(6) Place a towel under the water valve and use the adjustable wrench to remove the main hose connection.
(7) Next, remove the hoses that to into the water valve outlets. On my refrigerator, these hoses are of different sizes and have quick-disconnects. I simply have to press on the collar at end of the hose, pushing it towards the valve to release the hose, then pull on the hose.
(8) Prepare the new water valve by removing the plastic cover that protects the connector for the main water line.
(9) Connect the main water line to the new valve using the adjustable wrench.
(10) Connect the two hoses of different sizes to the valve. You only have to push them all the way into each valve and slightly tug on them to make sure they are locked in place.
(11) Re-connect the Brown and Blue electrical connectors to their original location.
(12) Mount the new water valve into the back of the refrigerator (one screw).
(13) If possible, quickly check that the new valve is working properly: If you have a mechanical valve in the water line, open it and make sure there are no leaks near the valve or inside in the icemaker. You may have to plug in the refrigerator power to complete the initial test.
(14) Replace the back panel with the 4 screws and anchor the hose to the back with 1 screw.
(15) Once everything is back in its place and the refrigerator is on, cycle the water dispenser several times to run fresh water into the hoses and the new valve.
Parts Used:
WATER VALVE WITH GUARD
  • Noel from San Jose, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
72 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan not running
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
Parts Used:
DC Condenser Fan Motor - 12V
  • Ray from Bensalem, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
74 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Leaking @ Quick Releases (Blue and White)
Had previously replace the plastic Water Tank, but when installing it I didn't realize how the quick connects worked. Instead of simply pushing inward in the direction of the blue part of the disconnect, I had pulled out the white ring on the outside of the disconnects. This ruined the inside connections and caused them to leak thus requiring these repairs. Had I known that I wouldnt have bought these parts too. Just Always REMEMBER to push in outside white ring on the quick disconnect and as you push it in pull out the hose when you remove it. To put the hose back in, just push it back in without pushing on ring this time at all and it will lock in place, and shouldn't be leaking. I had to run water into a glass to test if it was leaking, otherwise the line had no water pressure.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch WATER VALVE WITH GUARD
  • randy from vancouver, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
57 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!

-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!

-Set both temp control knots to 5 & put back all the food!

-If no ice build up on the panel after 10 days & then the repair is good!
Parts Used:
Defrost Heater and Bracket Assembly
  • Eddie from Freeport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
52 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge smelled like something electronic was burning
Removed the back cover of the fridge with it still pluged in. The next time the compressor tried to kick on, a small piece of black plastic next to the black tank caught fire, and then went out. I unpluged the fridge, unpluged the two wires feeding the black box. Then the box unpluged from the tank. I searched on the internet for the part using the model #. It ended up being a overload/ptc or relay. There was a smaller black box attached with I think is some sort of an overload. I unplugged the overload and it plugged right into the new relay I had overnighted. Although the new relay was white (not black) and the plug attachments were in different locations, it work great.
Parts Used:
Overload/Start Relay Combination
  • BENJAMIN from LAKESIDE, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
50 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PIR23MGTABV
1 - 15 of 501