The relay had burnt up.
I Removed the two wires from the old relay. I Then pulled the old relay off the compressor. Next, I had to get the overload seperated from the old burnt relay, which took some care not to break. The old relay and overload is in a plastic compartment. Then I followed the directions that came with the new relay. The only confusion came with getting the two wires back onto the terminals of the new relay, mainly because the old relay was burnt so badly I didn't have any idea how it was originally wired. I crossed the two wires on the terminals of the relay. The compressor would click off and on, but would not start blowing cold air. I swapped the wires on the terminals and it started working immediately.
Parts Used:
Relay and Overload Kit
  • Jacob from Glennville, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not cooling, freezer thawing but cold.
I removed the back lower panel within the freezer compartment. The cooling fan which draws cold air from the evaporator unit was functioning fine. I then unplugged the unit.
The evaporator unit was frozen in a block of ice. I removed all food contents from both the freezer and the refrigerator, moving them to a back-up refrigerator. I then allowed the radiator to thaw completely overnight. Upon restarting the unit it became cold within an hour thus I new the compressor was fine. I surmised it must be a defrost issue. I then unconnected the defrost heater and thermostat assembly. The device was easy to remove. I then routed the wire of the new assembly on the side of the evaporator unit and clipped the thermostat back onto the cooper feed, plugged the unit into the connection. Next I turned my attention to replacing the adaptive defrost timer. In the top of the refrigerator compartment, I removed the plastic shroud, by sliding back and pushing the plastic clips in. I took out 4 screws holding the unit to the ceiling of the refrigerator. Slowly lowering this, I could see the adaptive defrost timer in the right rear corner. I simply unplugged the unit and replaced with a new unit. I replaced both items although I am unsure which was not working. Refrigerator is working fine now.
Parts Used:
Defrost Heater and Thermostat Assembly Adaptive Defrost Board Water Filter Bypass Plug Door Shelf Bucket Stop Light Bulb - 7W Light Bulb - 40W
  • Thomas from Queensbury, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken light switch
followed the instructions provided and that's it!
Parts Used:
Door Switch
  • Richard from West Warwick, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator and freezer not cold enough
I don't know anything about repairing a refrigerator - I'm a computer tech. I noticed that the outside of the fridge was warm to the touch and the inside was not getting as cold as it should. I took the lower back panel behind the fridge off and noticed that the fan was not spinning. The local parts dealers did not have the condenser fan motor that was needed but they did say that they do go bad. I decided to order one from PartSelect.com and do it myself. Using a 1/4 inch nut driver and a flat head screw driver to pry the old motor out of the casing, I got the job done in about an hour or so. It's a relativly easy job. Besides the ouside panel screws, there's 3 screws on the inside near the fan blades you have to reach in to get. Pop out the whole assembly, unscrew the nut that holds the blades on and pry out the old motor and replace.. Try it yourself and save a couple hundred bucks!
Parts Used:
Condenser Fan Motor
  • Greg from Williamstown, NJ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The threads on the yoke shaft stripped.
I had to cut off the old yoke since the threads had stripped and it would not come off. Once I did that all I had to do was to remove 4 screws on the auger motor and replace it with the new auger motor. Then I put the yoke on the new auger motor shaft and then put the unit back in the freezer. Work time was less than 15 minutes with no problems.
Parts Used:
Ice Dispenser Engagement Yoke
  • Steven from Crossville, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench set
16 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bottom of freezer compartment was icing up/freezer was leaking water
UNPLUG YOUR FRIDGE BEFORE YOU START> First I removed the shroud covering the lights and controls in the top of the refrigerator side. This was the hardest part, actually. Their are two indentations on the back of the cover and it is really hard to pull that cover off. Anyhow, once you do that, their are two screws, one by each light bulb in the top of the fridge that need to be removed. Their are also three hex head screws that need to be removed, two in the front corners of the assembly, one in the center, back of the fridge. Take those out and the whole assembly drops down. In the back right had corner of the assembly is the adaptive defrost control. Unplug it and set it aside. Plug the new one in. Put everything back together and you are back in business.
Parts Used:
Adaptive Defrost Board
  • Jason from Clarkston, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice machine motor broke from housing & fridge door lower hinge worn, so door is staying closed
Just pulled out ice bucket put to the side and then pulled out framed housing that surrounds the ice bucket tray and put on table
went in the rear where the turn motor is and disconnected the wires from the housing next to it and disconnected the motor which had cracked the wal it was mounted to and broke and fell which left a huge hole and the , took the 4 screws out and remounted it onto the new housing rear wall, note that to get the twist key lever that unscrews clock wise you may have to hit wit a hammer bluntly to brak it lose first then it unscrews easy, but this has to be done first before re assembly of the motor as it goes through the new housing wall , once this is donr then put your screw end through the hole and re assemble the wing devise back onto the moter screw drive which it will screw on counter clockwise and tap a few quick times to snug with a ball hamer or a small hammer, T
The hinge door pin is real easy, just unscrew the top of door 3 screwa and lift off the door set aside put new door pin hinge on then set the door back onto the pin hole align up and set it back down in the hinge hole and replace screws on the upper door hinge on top of fridge. all this took about 5 minutes tops, it took me more time to take all the items out of the doorway of my fridge that it did to do the task itself. Hope this could help.
Parts Used:
Ice Bucket Support Enclosure Lower Hinge Pin
  • David from Spring Hill, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker not dispensing ice
Removed about 6 screws. Replaced the solenoid and door kit. Replaced the screws. These parts were easy to replace. They were also super easy to identify and order from the site. I received them two days after I placed my order.
Thanks partselect.com!
Parts Used:
Ice Dispenser Solenoid and Door Kit
  • Travis from Westchester, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Parts Used:
Door Switch
  • Kenneth from Newton Grove, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve had cracked in a move and was leaking badly
Replaced the water valve with the new part by removing 2 screws to allow folding back of the cover, removing 1 screw and pulling valve assembly out. 1 more screw took the two valves apart, unscrewed the water lines, replaced them on new valve (with newer push-in connections it was even easier), reassembled unit, turned the water on, checked for leaks, none found. Works great, was very easy.
Parts Used:
Water Filter Double Inlet Water Valve SUPPORT
  • Kelly from Rifle, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker leaked water
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Parts Used:
Replacement Ice Maker
  • Robert from Pennsylvania Furnace, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
didn't eject icecubes
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Parts Used:
Replacement Ice Maker
  • Ronald from Marion, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken (froze) ice maker water valve.
1. Turn off fridge and Pull plug from wall.
1a. Turn OFF water supply!
2. Remove rear dust cover to gain access to water valve.
3. Mark power connectors(red/green) attached to water valve before removing them. Remove connectors.
4. Remove supply line from old valve.
5. loosen mounting screw holding old valve in place.
6. remove valve.
7. disconnect two plastic water lines from valve.
8. Cut 1/2 inch off the end of each plastic line to get to un-streached line. Make sure you have enough line to still reach valve!
9. Insert plastic lines FIRMLY into outlets of NEW VALVE to lock in place. outlets are different sizes so you can't reverse them!
10. Install new valve and tighten mounting screw.
11. replace/tighten supply line to new valve.
13. Replace dust cover!
14. Plug in, Turn on fridge.
15. Turn on water supply, bleed air out by drawing a glass of water at door, and check for leaks!
All Done!
Parts Used:
Double Inlet Water Valve
  • richard from Little Suamico, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Parts Used:
Cycling thermostat
  • John from Rocky River, OH
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator would not cool but freezer worked fine
I removed the plastic housing inside the top of the rerigerator. Next I removed one hex head screw on the right side that screwed into the back wall using a 1/4 inch nut driver and I removed four hex head screws that screwed up through the temperature control unit into the top. There were two phillips head screws that had to be loosened, but not removed, that also scewed up through the assembly. After the hex head screws were removed, the whole assembly pulls out about an inch then drops down. Once it's down you can remove the adaptive defrost circuit board in the right rear corner of the unit. It's fixed! Thanks
Parts Used:
Adaptive Defrost Board
  • sylvia from dawsonville, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!